1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0522NMNN2NNRNWX
MDN4083LEA0522NMNN2NNRNWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN2NNRNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
PGF36060U64AE1YP
PGF36060U64AE1YP
Schneider Electric - Molded Case
PGF36060U64AE1YP, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 600A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with fixed handle padlocking device, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNKNYNCCAX
MDN4083LEA0122NMNKNYNCCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNKNYNCCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNJ4ECNMAX
MDN4083LEA0622NMNJ4ECNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ4ECNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSB5G8W71
SSB5G8W71
General Electric - Insulated Case
SSB5G8W71, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PJF36060CU43BAC
PJF36060CU43BAC
Square D - Molded Case
PJF36060CU43BAC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 3A/3B auxiliary switch, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
JGC305036GCVH09
JGC305036GCVH09
Cutler Hammer - Molded Case
JGC305036GCVH09, Cutler Hammer, Series G, type , 3P, 3PH, 50A, 600V, 100kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price
Limited Stock
SED36800LIES3
SED36800LIES3
Square D - Insulated Case
SED36800LIES3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0222NMNENYNCCCX
MDN4083LEA0222NMNENYNCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNENYNCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNENNNKNSX
MDN4083LEA0222NMNENNNKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNENNNKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNK2ENRCCX
MDN4083LEA0322NMNK2ENRCCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK2ENRCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNG4YNYNWX
MDN4083LEA0322NMNG4YNYNWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG4YNYNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHB4G7R9W
SHB4G7R9W
General Electric - Insulated Case
SHB4G7R9W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0422NMNNNYNKCPX
MDN4083LEA0422NMNNNYNKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNNNYNKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
E4H-A32-4P-1000A-DO-EO-LSI
E4H-A32-4P-1000A-DO-EO-LSI
ABB - Insulated Case
E4H-A32-4P-1000A-DO-EO-LSI, ABB, EMax, type , 4P, 3PH, 3200A frame, 1000A rating plug, 600V, 85kA@480V, Draw-Out, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
PLD34120U41ARD10
PLD34120U41ARD10
Schneider Electric - Molded Case
PLD34120U41ARD10, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Draw-Out, complete with direct mounted standard black handle, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
EGE3060FFGVH08
EGE3060FFGVH08
Cutler Hammer - Molded Case
EGE3060FFGVH08, Cutler Hammer, Series G, type , 3P, 3PH, 60A, 600V, 25kA@480V, standard interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SEF364000LIGET6
SEF364000LIGET6
Schneider Electric - Insulated Case
SEF364000LIGET6, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SSF4G6Z2T
SSF4G6Z2T
General Electric - Insulated Case
SSF4G6Z2T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
RLE-2000A-EO-BO-LIG
RLE-2000A-EO-BO-LIG
Siemens-Allis - Air
RLE-2000A-EO-BO-LIG, Siemens-Allis, RL Series, type , 2000A frame size, electrically operated/stationary mounted, 3P, 3PH, 1200-2000A current sensor rating, 600V, 100kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LIG - Long-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNJNYNCMSX
MDN4083LEA0222NMNJNYNCMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNJNYNCMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEF36250LSGB4
SEF36250LSGB4
Square D - Insulated Case
SEF36250LSGB4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNR4ECNNAX
MDN4083LEA0722NMNR4ECNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR4ECNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNE2NNKCCX
MDN4083LEA0422NMNE2NNKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNE2NNKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price