


- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

SSF5G814R
General Electric - Insulated Case
SSF5G814R, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SED364000LSGES6F4
Schneider Electric - Insulated Case
SED364000LSGES6F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

EGS4030FFGVH09
Cutler Hammer - Molded Case
EGS4030FFGVH09, Cutler Hammer, Series G, type , 4P, 3PH, 30A, 600V, 35kA@480V, standard interrupting capacity, for Naval applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price

MDN4083LEA0322NMNX4ENANCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNX4ENANCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0122NMNRNNNCNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNNNCNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SHB1G1N9C
General Electric - Insulated Case
SHB1G1N9C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0722NMNN4ENKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4ENKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0322NMNH2NNAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH2NNAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

SHB4G7A7U
General Electric - Insulated Case
SHB4G7A7U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & RELT features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

B216LIGZ1MR
General Electric - Trip Units And Programmers
B216LIGZ1MR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 1600A current sensor rating, Solid State electronic, LIG - Long-Time, Instantaneous and Ground Fault, trip functions, zone selective interlock, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price

MDN4083LEA0122NMNH4ENRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNH4ENRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

EGC7070FFGVH09
Cutler Hammer - Molded Case
EGC7070FFGVH09, Cutler Hammer, Series G, type , 4P, 3PH, 70A, 600V, 100kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price

SEHF363200LSGES7A8
Square D - Insulated Case
SEHF363200LSGES7A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHD363200LSIGES9B4
Schneider Electric - Insulated Case
SEHD363200LSIGES9B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0422NMNH4YNCNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH4YNCNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SEF361600LIES1D4
Square D - Insulated Case
SEF361600LIES1D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0522NMNXNNNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNXNNNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

HJK260506
Square D - Molded Case
HJK260506, Square D, Schneider Electric, PowerPact, type , 2P, C & B phase connection, 1PH, 50A, 600V, 65kA@480V, UL listed, current limiting, reverse I-Line Style Plug-In, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price

SEHD364000LIES4C8
Square D - Insulated Case
SEHD364000LIES4C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

WLH1F320RP
Siemens - Insulated Case
WLH1F320RP, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 2000A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU748 programmer+ WLGFM48 ground fault module, LSG - Long-Time, Short-Time and Ground Fault trip functions and 1250A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

SEF36350LIES8D4
Square D - Insulated Case
SEF36350LIES8D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0822NMNGNENYMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNGNENYMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SEF36300LIGES8D4
Square D - Insulated Case
SEF36300LIGES8D4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 300A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SSB1G3M7N
General Electric - Insulated Case
SSB1G3M7N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price