MDN4083LEA0522NMNJ2ENCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNJ2ENCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0622NMNK2YNADCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK2YNADCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

B1H1D6
Noark Electric - Molded Case
B1H1D6, Noark Electric, UL 489, type , 1PH, 1P, 277V, 6A, 10kA@277V, Feed-Thru box terminals, D trip curve, Thermal Magnetic, din rail mounted molded case circuit breakers
From Get Price

SSF6G9522
General Electric - Insulated Case
SSF6G9522, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

WLL2D308AH
Siemens - Insulated Case
WLL2D308AH, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 800A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLLCD48 LCD display + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

SHD6G9F1U
General Electric - Insulated Case
SHD6G9F1U, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SEHD36350LSIES9B4
Schneider Electric - Insulated Case
SEHD36350LSIES9B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHD36800LSES7C4
Schneider Electric - Insulated Case
SEHD36800LSES7C4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 800A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0122NMNANECNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNANECNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0122NMNN4ENCCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN4ENCCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

FD3200VH08
Eaton - Molded Case
FD3200VH08, Westinghouse, Cutler Hammer, Eaton, Series C, type , 3P, 3PH, 200A, 600V, 35kA@480V, standard interrupting capacity, Marine 50℃ ambient calibration, vibration testing, and no use of Al terminals, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers for Marine applications, not UL listed
From Get Price

MDN4083LEA0822NMNG2ENNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG2ENNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions,& load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SEHF361200LSIES2A8
Schneider Electric - Insulated Case
SEHF361200LSIES2A8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0222NMNN2NNYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN2NNYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price

WLL1F316TG
Siemens - Insulated Case
WLL1F316TG, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 1600A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNR4YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR4YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SEHF362000LIGES2D4
Square D - Insulated Case
SEHF362000LIGES2D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PKF36100CU63AE1RE10
Square D - Molded Case
PKF36100CU63AE1RE10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1000A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with door mounted standard black handle, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price

MDS8324WEA
Cutler Hammer - Insulated Case
MDS8324WEA, Cutler Hammer, Magnum DS, type , drawout mounted, standard frame, 4P with neutral, 3PH, NABC phase, 3200A, 600V, 85kA@600V, 40°C, Bolt-On, complete with interchangeable Digitrip, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price

SEHF361600LIET3
Schneider Electric - Insulated Case
SEHF361600LIET3, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

GNS3125T36WP04
Cutler Hammer - Molded Case
GNS3125T36WP04, Cutler Hammer, Series G, type , 1250A frame, 3P, 3PH, 600V, 50kA@480V, standard interrupting capacity, Bolt-On, complete with Digitrip RMS 310 trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, 800A fixed rating plug, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price

SEHD361400LIGES1F8
Schneider Electric - Insulated Case
SEHD361400LIGES1F8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MPA41F20W4450
General Electric - Insulated Case
MPA41F20W4450, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac motor operator, 220/250V dc/ac closing coil and 380/400V ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price

TPSS6608FCSG
General Electric - Insulated Case
TPSS6608FCSG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 800A, Front Connected, with ground fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price