- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

SHD1G259D
General Electric - Insulated Case
SHD1G259D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SEF362500LSES1B8
Square D - Insulated Case
SEF362500LSES1B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PDG33K0125E3NK
Cutler Hammer - Molded Case
PDG33K0125E3NK, Cutler Hammer, Eaton, Power Defense, type , 3PH, 3P, 600V, 125A, 50kA@480V, Bolt-On, line side lug terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions , Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

MDN4083LEA0622NMNA4NNAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA4NNAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SEF36400ES7B8
Schneider Electric - Insulated Case
SEF36400ES7B8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0322NMNKNNNNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNKNNNNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, with shutters, unwired
From Get Price

SSB4G7X81
General Electric - Insulated Case
SSB4G7X81, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0822NMNN2NNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN2NNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0322NMNA2YNYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA2YNYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

JGS410036GVH08
Cutler Hammer - Molded Case
JGS410036GVH08, Cutler Hammer, Series G, type , 4P, 3PH, 100A, 600V, 35kA@480V, high interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price

KHL361001042
Square D - Molded Case
KHL361001042, Square D, KHL Series, type , 3P, 3PH, 100A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, complete with 24Vac shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price

SEHD36250LIES8B4
Square D - Insulated Case
SEHD36250LIES8B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

LGG1B070
Siemens - Molded Case
LGG1B070, Siemens, VL Series, type , 1P, 1PH, 70A, 347V, 65kA@277V, standard interrupting capacity, suitable for reverse feed applications and screws or DIN rail mounting, Bolt-On, complete with LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, molded case circuit breakers
From Get Price

MDN4083LEA0222NMNA2YNNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA2YNNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0622NMNJNNNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJNNNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & Castell key interlock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

FCL340251128
Square D - Molded Case
FCL340251128, Square D, FCL Series, type , 3P, 3PH, 25A, 480V, 65kA@480V, extra high interrupting capacity, Feed-Thru, complete with 48Vdc UVR, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

TMQL21110
General Electric - Molded Case
TMQL21110, General Electric, Meter Mod, tenant main circuit breakers for 125A sockets, type , 2P, 1PH, 110A, 120/240V, 42kA@240V, UL listed, Plug-In, complete with LI - Long-Time and Instantaneous trip functions and load side lug terminal, Thermal Magnetic, molded case circuit breaker
From Get Price

MDN4083LEA0722NMNJNENNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJNENNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, ships in drawout narrow breakers without shutters, pre-wired
From Get Price

SEHD36300LSES5B8
Square D - Insulated Case
SEHD36300LSES5B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0122NMNG2ENYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNG2ENYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

WLH1F312JR
Siemens - Insulated Case
WLH1F312JR, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU755 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 500A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

JGU316035GVH09
Cutler Hammer - Molded Case
JGU316035GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 160A, 600V, 150kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price

PDG32GH250E4RL
Eaton - Molded Case
PDG32GH250E4RL, Eaton, Cutler Hammer, Power Defense, type , 600A frame, 1PH, 2P, 600V, 250A, high override, 35kA@480V, Bolt-On, load side lug terminals, complete with PXR20 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

MDN4083LEA0122NMNN4ENHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN4ENHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price