SEF36250LSES4D5
SEF36250LSES4D5
Square D - Insulated Case
SEF36250LSES4D5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete
From Get Price
Limited Stock
NRLF36060CU74BE1
NRLF36060CU74BE1
Schneider Electric - Molded Case
NRLF36060CU74BE1, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 600A, 600V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEF363200LSIES8C8
SEF363200LSIES8C8
Square D - Insulated Case
SEF363200LSIES8C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNGNYNRCAX
MDN4083LEA0122NMNGNYNRCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNGNYNRCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNH2YNHDWX
MDN4083LEA0822NMNH2YNHDWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2YNHDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SED361000ES1B4
SED361000ES1B4
Square D - Insulated Case
SED361000ES1B4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNC4ECNNPX
MDN4083LEA0622NMNC4ECNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4ECNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
WLL3F340PN
WLL3F340PN
Siemens - Insulated Case
WLL3F340PN, Siemens, WL Series, type , frame size III, fixed mount, 3P, 3PH, 4000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 1000A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNE4ENYCPX
MDN4083LEA0122NMNE4ENYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNE4ENYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNNNYNLNWX
MDN4083LEA0222NMNNNYNLNWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNNNYNLNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHD4G468P
SHD4G468P
General Electric - Insulated Case
SHD4G468P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA42F4001350
MPA42F4001350
General Electric - Insulated Case
MPA42F4001350, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, 24/30V dc motor operator, 110/130V dc/ac closing coil and 380/400V ac shunt trip, 4P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNRNYNYNPX
MDN4083LEA0522NMNRNYNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNRNYNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB4G6L6W
SSB4G6L6W
General Electric - Insulated Case
SSB4G6L6W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
XT2LQ4090BFF000XXX
XT2LQ4090BFF000XXX
ABB - Molded Case
XT2LQ4090BFF000XXX, ABB, molded case circuit breaker, SACE Tmax XT, Type , 4-Pole, 90A, 600V, 35kA@600V, Thermal magnetic adjustable (TMD/TMA), UL 100% Rated, Line Side Termination (top): F front terminals no lugs installed, Load Side Termination (bottom): F front terminals no lugs installed, No
From Get Price
Limited Stock
SSD1G1F7A
SSD1G1F7A
General Electric - Insulated Case
SSD1G1F7A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD3G6E3U
SSD3G6E3U
General Electric - Insulated Case
SSD3G6E3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
Q320H00S07
Q320H00S07
Siemens - Molded Case
Q320H00S07 Siemens Q Series, type , 3P, 3PH, 20A, 240V, 22kA@240V, high interrupting capacity, with factory installed 24V shunt trip, Plug-In, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNX2NNYNSX
MDN4083LEA0522NMNX2NNYNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX2NNYNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNN2NNHDCX
MDN4083LEA0122NMNN2NNHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2NNHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
WLH1F312DH
WLH1F312DH
Siemens - Insulated Case
WLH1F312DH, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLLCD48 LCD display + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 300A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SEHF361400LSIES8A8
SEHF361400LSIES8A8
Square D - Insulated Case
SEHF361400LSIES8A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
709733T04
709733T04
ABB - Metering
709733T04, ABB, BBC, ITE, K-Line, Lower Base Molding w/Phase and Power Sensors, Use w/ MPSC-2000 Trip Device, suitable for use with K/K-Don600S/800S
From Get Price
Limited Stock
SHF1G183A
SHF1G183A
General Electric - Insulated Case
SHF1G183A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price