


- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

NPJP36025U41A
Schneider Electric - Molded Case
NPJP36025U41A, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0422NMNN4ECNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4ECNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SEHD36300LSES1A4
Schneider Electric - Insulated Case
SEHD36300LSES1A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHF362500LIT3
Schneider Electric - Insulated Case
SEHF362500LIT3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 48VDC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SHD5G8N72
General Electric - Insulated Case
SHD5G8N72, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

E4V-A36-4P-2500A-BO-MO-LSI
ABB - Insulated Case
E4V-A36-4P-2500A-BO-MO-LSI, ABB, EMax, type , 4P, 3PH, 3600A frame, 2500A rating plug, 600V, 100kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price

MDN4083LEA0722NMNG2YNNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG2YNNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0222NMNNNYNNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNNNYNNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SEF361000LSGES2A8
Square D - Insulated Case
SEF361000LSGES2A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0722NMNA4ENCMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNA4ENCMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SED36200LSES6D8
Schneider Electric - Insulated Case
SED36200LSES6D8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0822NMNF4ENRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF4ENRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

E3X-A12-4P-400A-DO-EO-LI
ABB - Insulated Case
E3X-A12-4P-400A-DO-EO-LI, ABB, EMax, type , 4P, 3PH, 1200A frame, 400A rating plug, 600V, 200kA@480V, Draw-Out, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price

MDN4083LEA0222NMNHNYNACSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNHNYNACSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0322NMNJ2YNKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJ2YNKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0622NMNH4NNKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNH4NNKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

140U-JTH3-D25
Allen-Bradley - Trip Units And Programmers
140U-JTH3-D25, Allen-Bradley, Bulletin 140U, type , interchangeable trip units and programmers, LSI - Long-Time, Short-Time and Instantaneous trip functions, rated for 250A, suitable for 250A J2L,J2H,J2G,J2I,J3L,J3H,J3G,J3I,J6L,J6H,J6G,J6I molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

SED361600LIGES3A4
Square D - Insulated Case
SED361600LIGES3A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHD36250LIGES7B8
Schneider Electric - Insulated Case
SEHD36250LIGES7B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEHF36350T1
Square D - Insulated Case
SEHF36350T1, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 120VAC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0422NMNE2NNNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNE2NNNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

FAR26020BC
Square D - Molded Case
FAR26020BC, Square D, I-Line, type , 2P, 1PH, 20A, 600V, 18kA@480V, standard interrupting rating, 40ºC, with I-line drawout connectors, I-Line Style Plug-In, B & C phase circuit configuration, with I-Line drawout connectors and plug-on connector blocks sold separately, Thermal Magnetic, molded case circuit breakers
From Get Price

SED361000LSIES4E5
Schneider Electric - Insulated Case
SED361000LSIES4E5, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete
From Get Price

SHF3G6W8T
General Electric - Insulated Case
SHF3G6W8T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price