


- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

SSB2G4Q3N
General Electric - Insulated Case
SSB2G4Q3N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0322NMNN2ENKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2ENKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

PKD36060CU44AAC
Square D - Molded Case
PKD36060CU44AAC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 600V, 50kA@480V, UL listed, high interrupting capacity, Draw-Out, 100% rated, complete with 3A/3B auxiliary switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, molded case circuit breakers
From Get Price

SED362500LSES5
Schneider Electric - Insulated Case
SED362500LSES5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0622NMNR2YNAMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR2YNAMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SEHD36350LSIET6
Schneider Electric - Insulated Case
SEHD36350LSIET6, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEF36800LIES5D8
Schneider Electric - Insulated Case
SEF36800LIES5D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PKL36080U41BBC
Square D - Molded Case
PKL36080U41BBC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 800A, 600V, 50kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with 1A/1B alarm switch, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0322NMNN2YNCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2YNCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0222NMNH4ENNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4ENNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SEF36600ET3
Schneider Electric - Insulated Case
SEF36600ET3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

XT7LQ410DEFF000XXX
ABB - Molded Case
XT7LQ410DEFF000XXX, ABB, SACE Tmax XT, type , UL 100% rated, 3PH, 4P, 600V, 1000A, 100kA@480V, , front terminals, complete with Ekip Dip LS/I trip, Ekip LS/I (Electronic, LS/I protection), molded case circuit breakers; 1SDA103224R1 + 1SDA107724R1 global reference
From Get Price

PKP36040U63BE1AB
Square D - Molded Case
PKP36040U63BE1AB, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with 2A/2B auxiliary switch, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

SEF362000LSIGES8A8
Square D - Insulated Case
SEF362000LSIGES8A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0122NMNF2YNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF2YNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price

RLF-3200A-EO-BO-LSIG
Siemens-Allis - Air
RLF-3200A-EO-BO-LSIG, Siemens-Allis, RL Series, type , fused 3200A frame size, separate drawout fuse carriage, electrically operated/stationary mounted, 3P, 3PH, 1200-3200A current sensor rating, 600V, 200kA@480V, originally supplied with StaticTrip III RMS trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price

SPB65-3P-1000A-EO-BO-LI
Cutler Hammer - Insulated Case
SPB65-3P-1000A-EO-BO-LI, Cutler Hammer, Systems Pow-R, type , 1600A frame size, 3P, 3PH, 1000A, 600V, 65kA@480V, standard interrupting capacity, Bolt-On, electrically operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LI - Long-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

SEF36250LSES8
Schneider Electric - Insulated Case
SEF36250LSES8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

FDC4035VL
Westinghouse - Molded Case
FDC4035VL, Cutler Hammer, Eaton, Westinghouse, Series C, type , 4P, 3PH, 35A, 600V, 100kA@480V, current limiting, 50°C, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price

MDN4083LEA0822NMNA2NHNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2NHNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SSF1G322K
General Electric - Insulated Case
SSF1G322K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SEHF363000LSIGES8C8
Square D - Insulated Case
SEHF363000LSIGES8C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PDG32P0400P4DN
Cutler Hammer - Molded Case
PDG32P0400P4DN, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 400A, 100kA@480V, Bolt-On, no lug terminals, complete with PXR25 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions with MODBUS RTU, CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price

PGP36040U64AE1AB
Schneider Electric - Molded Case
PGP36040U64AE1AB, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with 2A/2B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price