1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0422NMNC2YNKCPX
MDN4083LEA0422NMNC2YNKCPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC2YNKCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB1G151C
SSB1G151C
General Electric - Insulated Case
SSB1G151C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNG2ENADSX
MDN4083LEA0522NMNG2ENADSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG2ENADSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHF5G8N2W
SHF5G8N2W
General Electric - Insulated Case
SHF5G8N2W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122CNAC4ENNNAX
MDN4083LEA0122CNAC4ENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122CNAC4ENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 24Vdc shunt trip (ST), 24Vdc UVR, 4A/4B auxiliary switch, electrically operated with factory installed 110-120Vac motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNR4ENLDCX
MDN4083LEA0322NMNR4ENLDCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNR4ENLDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHF4G7L4U
SHF4G7L4U
General Electric - Insulated Case
SHF4G7L4U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNX4YHNMPX
MDN4083LEA0522NMNX4YHNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX4YHNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC2YHNDSX
MDN4083LEA0122NMNC2YHNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2YHNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNANENCMPX
MDN4083LEA0322NMNANENCMPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANENCMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
LGC363038GVH09
LGC363038GVH09
Cutler Hammer - Molded Case
LGC363038GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 630A, 600V, 100kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip, ALSI - Arcflash Reduction, Long-Time, Short-Time and Instantaneous trip functions with arcflash reduction maintenance system and line & load side lug terminals, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNF2YNHDSX
MDN4083LEA0722NMNF2YNHDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF2YNHDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSB1G3H2F
SSB1G3H2F
General Electric - Insulated Case
SSB1G3H2F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT, modbus communication & relays features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNK2NNAMWX
MDN4083LEA0222NMNK2NNAMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK2NNAMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHF4G6E7R
SHF4G6E7R
General Electric - Insulated Case
SHF4G6E7R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT & modbus communication features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB2G533Q
SSB2G533Q
General Electric - Insulated Case
SSB2G533Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF5G8C72
SSF5G8C72
General Electric - Insulated Case
SSF5G8C72, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB4G6N9N
SHB4G6N9N
General Electric - Insulated Case
SHB4G6N9N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNC2NNRDWX
MDN4083LEA0122NMNC2NNRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2NNRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
JGX325035GCH08
JGX325035GCH08
Cutler Hammer - Molded Case
JGX325035GCH08, Cutler Hammer, Series G, type , 3P, 3PH, 250A, 600V, 200kA@480V, current limiting, UL listed for Marine applications 40°C, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNX4YNLMWX
MDN4083LEA0622NMNX4YNLMWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4YNLMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNJNYNADPX
MDN4083LEA0722NMNJNYNADPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJNYNADPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNA4ENKDWX
MDN4083LEA0322NMNA4ENKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4ENKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNA2YHNDWX
MDN4083LEA0422NMNA2YHNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2YHNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price