1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNENYCNNCX
MDN4083LEA0822NMNENYCNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNENYCNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0322NMNF4YNKMPX
MDN4083LEA0322NMNF4YNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNF4YNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MUVH1LT26K
MUVH1LT26K
Cutler Hammer - Under Voltage Release
MUVH1LT26K, Cutler Hammer, Series C, type , under voltage release, 110 - 127Vdc, left side mounted, terminal block style, 1 undervoltage release mechanism, suitable for use with F-frame HMCP molded case circuit breakers
From Get Price
Limited Stock
WLL2F312QN
WLL2F312QN
Siemens - Insulated Case
WLL2F312QN, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1200A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 1200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNA2NNRDCX
MDN4083LEA0622NMNA2NNRDCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA2NNRDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
AKST-4-50H
AKST-4-50H
General Electric - Air
AKST-4-50H, General Electric, AK Series, type , 2000A frame, 3PH, 3P, 635VAC, 800-2000A sensor rating, 42kA@508V, Draw-Out, available either mechanically or electrically operated, with ECS Solid State programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage air circuit breakers
From Get Price
Limited Stock
EEFDC260100SB2
EEFDC260100SB2
Cutler Hammer - Mounting Hardware
EEFDC260100SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 100A, AC phase connection, 600V max, Copper, Single Branch mounting style, suitable for use with EHD,FDB,FD,HFD,FDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
SSD3G6F4P
SSD3G6F4P
General Electric - Insulated Case
SSD3G6F4P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering & modbus communication features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNKNNNCNWX
MDN4083LEA0822NMNKNNNCNWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNKNNNCNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNA4YNKDPX
MDN4083LEA0322NMNA4YNKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4YNKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNN2NNANPX
MDN4083LEA0122NMNN2NNANPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2NNANPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNHNNCNNPX
MDN4083LEA0522NMNHNNCNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNNCNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNC2YHNDCX
MDN4083LEA0622NMNC2YHNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC2YHNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
313C909H19
313C909H19
Cutler Hammer - Part And Accessory
313C909H19, Cutler Hammer, LB Series, tube connected stud assembly, 2 required per pole, 1-11/32 length
From Get Price
Limited Stock
MPA31F0801315
MPA31F0801315
General Electric - Insulated Case
MPA31F0801315, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 24/30V dc motor operator, 110/130V dc/ac closing coil, 24/30V ac shunt trip and 30/48V dc undervoltage trip with delay, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNK4ENCCPX
MDN4083LEA0522NMNK4ENCCPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4ENCCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB3G6H1M
SSB3G6H1M
General Electric - Insulated Case
SSB3G6H1M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication & relays features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
150DH150E
150DH150E
Westinghouse - Air
150DH150E, Westinghouse, Type 150DH, type , electrically operated, horizontal Draw-Out, 3P, 3PH, 1200A, 13800V, 150MVA, medium voltage power air circuit breakers for metal-clad switchgear
From Get Price
Limited Stock
MDN4083LEA0322NMNE4NNRCCX
MDN4083LEA0322NMNE4NNRCCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE4NNRCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
JM3250TK5M
JM3250TK5M
Cutler Hammer - Trip Units And Programmers
JM3250TK5M, Cutler Hammer, Series C mining, type , 3P, interchangeable trip, I - Instantaneous trip function, rated for 250A, magnetic trip range 1000-2000A, suitable for 250A- JDM,JDCM mining service Magnetic Only molded case circuit breaker frame types, Magnetic Only trip units & circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNX4ENYDCX
MDN4083LEA0622NMNX4ENYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4ENYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MP40-3P-2000A-EO-DO-LIG
MP40-3P-2000A-EO-DO-LIG
Merlin Gerin - Insulated Case
MP40-3P-2000A-EO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 2000A, 2500A, 3000A, 3200A or 4000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNN4NNLCWX
MDN4083LEA0322NMNN4NNLCWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN4NNLCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNF4NCNMAX
MDN4083LEA0722NMNF4NCNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF4NCNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price