1. Home / 
  2. square d breaker

SORT BY
Limited Stock
PEEH3ATAL0250
PEEH3ATAL0250
General Electric - Molded Case
PEEH3ATAL0250, General Electric, GuardEon, type , 3PH, 3P, 600V, 45-250A, 100kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G interchangeable trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MDN4083LEA0622NMNJ4YNCCAX
MDN4083LEA0622NMNJ4YNCCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ4YNCCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSD3G6Y7M
SSD3G6Y7M
General Electric - Insulated Case
SSD3G6Y7M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
WLL3D350T
WLL3D350T
Siemens - Insulated Case
WLL3D350T, Siemens, WL Series, type , frame size III, drawout, 3P, 3PH, 5000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state programmer with LSI - Long-Time, Short-Time and Instantaneous trip functions and 1600A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MPA41F20N0022
MPA41F20N0022
General Electric - Insulated Case
MPA41F20N0022, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc shunt trip and 110/130V ac undervoltage trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNK2YNCDWX
MDN4083LEA0722NMNK2YNCDWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK2YNCDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNANYNYMSX
MDN4083LEA0222NMNANYNYMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNANYNYMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MPH42M16
MPH42M16
General Electric - Insulated Case
MPH42M16, General Electric, M-PACT, type , frame size 2, manually operated, without cassette, moving portion only, 5 N.O.-3 N.C. Auxiliary switch, 4P, 3PH, 1600A, 690V, 80kA@415V, Draw-Out, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
SKSS3408L3W8
SKSS3408L3W8
General Electric - Molded Case
SKSS3408L3W8, General Electric, Spectra Series, type , 3P, 3PH, 800A, 480V, 100kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIZ - Long-Time, Short-Time, Instantaneous and ZSI trip functions with extended instantaneous, advanced metering + modbus features + waveform capture + relay features, Solid State with RELT + neutral protection, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNG2ENRNWX
MDN4083LEA0422NMNG2ENRNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG2ENRNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNCNYNHNWX
MDN4083LEA0222NMNCNYNHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNCNYNHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MPA31F0801134
MPA31F0801134
General Electric - Insulated Case
MPA31F0801134, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 24/30V dc motor operator, 24/30V dc closing coil, 110/130V dc/ac shunt trip and 380/440V ac undervoltage trip with delay, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
EEKDC340125SB2
EEKDC340125SB2
Cutler Hammer - Mounting Hardware
EEKDC340125SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 125A, ABC phase connection, 480V max, Copper, Single Branch mounting style, suitable for use with KD,HKD,KDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNKNENANPX
MDN4083LEA0522NMNKNENANPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNKNENANPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNR2ENRMWX
MDN4083LEA0822NMNR2ENRMWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNR2ENRMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNE2YNYNWX
MDN4083LEA0422NMNE2YNYNWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNE2YNYNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNJNNNNMPX
MDN4083LEA0122NMNJNNNNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJNNNNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, ships in drawout narrow cassettes without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNRNNNRNCX
MDN4083LEA0622NMNRNNNRNCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNRNNNRNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
21.305.0253.0
21.305.0253.0
Wieland - Tools
21.305.0253.0, Wieland tools
From Get Price
Limited Stock
MDN4083LEA0222NMNA2NNRNSX
MDN4083LEA0222NMNA2NNRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA2NNRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
THS202L07E5
THS202L07E5
General Electric - Insulated Case
THS202L07E5, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 700A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 24Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 2100-7000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNHNENLNPX
MDN4083LEA0122NMNHNENLNPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNHNENLNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNE4YNRCSX
MDN4083LEA0822NMNE4YNRCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNE4YNRCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHB4G496H
SHB4G496H
General Electric - Insulated Case
SHB4G496H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price