1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0422NMNX4ENNDPX
MDN4083LEA0422NMNX4ENNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNX4ENNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122HKHGNNNNNAX
MDN4083LEA0122HKHGNNNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122HKHGNNNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 48Vdc shunt trip (ST), 32Vdc UVR & mechanical trip indicator, electrically operated with factory installed 48Vdc motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNANYNNNWX
MDN4083LEA0522NMNANYNNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNANYNNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC2NNNCAX
MDN4083LEA0122NMNC2NNNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2NNNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
TRPA36BG20
TRPA36BG20
General Electric - Molded Case
TRPA36BG20 General Electric R Frame, type , 3P, 3PH, 2000A, 600V, 100kA@480V, high interrupting capacity, Bolt-On, suitable for reverse fed applications, complete with MicroVersaTrip Plus trip, LSIGTZ - Long-Time, Short-Time, Instantaneous, Ground Fault, Targets and ZSI trip functions and interchangeable rating plug, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNENYNLMAX
MDN4083LEA0622NMNENYNLMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNENYNLMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
P1E18ML125ABS
P1E18ML125ABS
Siemens - Panel Board
P1E18ML125ABS, Siemens, Type P1 panel board, 3-phase, 4-wire, 125A, 277/480V, Main Lug Only, 18 1-pole circuits, 32" box height, bottom feed, surface mounted, Aluminum bus
From Get Price
Limited Stock
MDN4083LEA0822NMNN4YNKDCX
MDN4083LEA0822NMNN4YNKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN4YNKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
P1C18JX400ABS
P1C18JX400ABS
Siemens - Panel Board
P1C18JX400ABS, Siemens, Type P1 panel board, 3-phase, 4-wire, 400A, 120/208V, Main Breaker style, to be used with FXD circuit breaker, 18 1-pole circuits, 56" box height, bottom feed, surface mounted, Aluminum bus
From Get Price
Limited Stock
MDN4083LEA0722NMNR2EHNMPX
MDN4083LEA0722NMNR2EHNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR2EHNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNA4YNNMCX
MDN4083LEA0322NMNA4YNNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4YNNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHF1G3L9N
SHF1G3L9N
General Electric - Insulated Case
SHF1G3L9N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNA4ENHNAX
MDN4083LEA0322NMNA4ENHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4ENHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNGNYMKNSX
MDN4083LEA0622NMNGNYMKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNGNYMKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNC2YHNNSX
MDN4083LEA0822NMNC2YHNNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC2YHNNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNX4NNRCPX
MDN4083LEA0722NMNX4NNRCPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4NNRCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
P1C18QJ225CTS
P1C18QJ225CTS
Siemens - Panel Board
P1C18QJ225CTS, Siemens, Type P1 panel board, 3-phase, 4-wire, 225A, 120/208V, Main Breaker style, to be used with FXD circuit breaker, 18 1-pole circuits, 32" box height, top feed, surface mounted, Copper bus
From Get Price
Limited Stock
MPA31F0803414
MPA31F0803414
General Electric - Insulated Case
MPA31F0803414, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 110/130V dc/ac motor operator, 220/250V dc/ac closing coil, 24/30V dc shunt trip and 380/440V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
SHF2G5N2P
SHF2G5N2P
General Electric - Insulated Case
SHF2G5N2P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E6H-A40-4P-1200A-BO-MO-LI
E6H-A40-4P-1200A-BO-MO-LI
ABB - Insulated Case
E6H-A40-4P-1200A-BO-MO-LI, ABB, EMax, type , 4P, 3PH, 4000A frame, 1200A rating plug, 600V, 85kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SHD2G4X7N
SHD2G4X7N
General Electric - Insulated Case
SHD2G4X7N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNNNYNNCAX
MDN4083LEA0622NMNNNYNNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNNNYNNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
366A773G12
366A773G12
General Electric - Closing Coil
366A773G12, General Electric, AK Series, renewal closing coil, V, suitable for use with AK-2-15,AK-2A-15,AK-2-25,AK-2A-25,AKU-2-25,AKU-2A-25,AKR-2A-30S,AKRU-2A-30S low voltage power air circuit breakers
From Get Price
Limited Stock
SHB4G764U
SHB4G764U
General Electric - Insulated Case
SHB4G764U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price