1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0122NMNRNENLNWX
MDN4083LEA0122NMNRNENLNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNENLNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
E6X-A40-4P-2000A-BO-EO-LSIG
E6X-A40-4P-2000A-BO-EO-LSIG
ABB - Insulated Case
E6X-A40-4P-2000A-BO-EO-LSIG, ABB, EMax, type , 4P, 3PH, 4000A frame, 2000A rating plug, 600V, 200kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0422NMNN4ENHNAX
MDN4083LEA0422NMNN4ENHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN4ENHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHD3G624T
SHD3G624T
General Electric - Insulated Case
SHD3G624T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communication & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122CNA2NYNNNAX
MDN4083LEA0122CNA2NYNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122CNA2NYNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 24Vdc shunt trip, 208-250Vac second shunt trip (ST), mechanical trip indicator & OTS switch, electrically operated with factory installed 110-120Vac motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNANYCNCCX
MDN4083LEA0422NMNANYCNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNANYCNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNG4NHKDPX
MDN4083LEA0122NMNG4NHKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNG4NHKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, latch check switch for external wiring, load side lug terminals, 4A/4B auxiliary switch, Kirk keylock, & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PDG33NH350TFAJ
PDG33NH350TFAJ
Cutler Hammer - Molded Case
PDG33NH350TFAJ, Eaton, Cutler Hammer, Power Defense, type , 600A frame, 3PH, 3P, 600V, 350A high override, 85kA@480V, Feed-Thru, line & load side lug terminals, complete with LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0622NMNF2NHNCSX
MDN4083LEA0622NMNF2NHNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF2NHNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNKNNNHDAX
MDN4083LEA0622NMNKNNNHDAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNKNNNHDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA32F32N2430
MPA32F32N2430
General Electric - Insulated Case
MPA32F32N2430, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc motor operator, 220/250V dc/ac closing coil, 110/130V dc/ac shunt trip, 3P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
FNT407216HSG5CT
FNT407216HSG5CT
General Electric - Part And Accessory
FNT407216HSG5CT, General Electric, EntellEon, type , panelboard front, Type 1 non-vented, top, 40 enclosure width
From Get Price
Limited Stock
SHF2G4L1N
SHF2G4L1N
General Electric - Insulated Case
SHF2G4L1N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNANNNADAX
MDN4083LEA0322NMNANNNADAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANNNADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
EGB4090AFGVH09
EGB4090AFGVH09
Cutler Hammer - Molded Case
EGB4090AFGVH09, Cutler Hammer, Series G, type , 4P, 3PH, 90A, 480V, 18kA@480V, standard interrupting capacity, for Naval applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SHD4G7M8U
SHD4G7M8U
General Electric - Insulated Case
SHD4G7M8U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
TRLL36BF16
TRLL36BF16
General Electric - Molded Case
TRLL36BF16 General Electric R Frame, type , 3P, 3PH, 1600A, 600V, 65kA@480V, standard interrupting capacity, Bolt-On, 100% rated, suitable for reverse fed applications, complete with MicroVersaTrip Plus trip, LSIGTZ - Long-Time, Short-Time, Instantaneous, Ground Fault, Targets and ZSI trip functions and interchangeable rating plug, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
SHB4G4J4N
SHB4G4J4N
General Electric - Insulated Case
SHB4G4J4N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication & relays features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
60A9355G13
60A9355G13
Cutler Hammer - Under Voltage Release
60A9355G13, Cutler Hammer, LA Series, under voltage release, 1 undervoltage release mechanism for field mounting, 480V, left side mounted, suitable for use with LA,LAB,HLA molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNN2ENACWX
MDN4083LEA0822NMNN2ENACWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN2ENACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNFNENADPX
MDN4083LEA0122NMNFNENADPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNFNENADPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSB4G6Y1U
SSB4G6Y1U
General Electric - Insulated Case
SSB4G6Y1U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communcation, relays & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNH2YNHNAX
MDN4083LEA0722NMNH2YNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2YNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHD5G8R32
SHD5G8R32
General Electric - Insulated Case
SHD5G8R32, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price