1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0422NMNN2YNKCSX
MDN4083LEA0422NMNN2YNKCSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNN2YNKCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNXNYNCCCX
MDN4083LEA0122NMNXNYNCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNXNYNCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNK2ENKMSX
MDN4083LEA0122NMNK2ENKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK2ENKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHF36350LSET5
SEHF36350LSET5
Square D - Insulated Case
SEHF36350LSET5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHD1G2M2C
SHD1G2M2C
General Electric - Insulated Case
SHD1G2M2C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNG4NHKNSX
MDN4083LEA0222NMNG4NHKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG4NHKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SSF2G561Q
SSF2G561Q
General Electric - Insulated Case
SSF2G561Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNG4NNKNSX
MDN4083LEA0222NMNG4NNKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG4NNKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PLP34040U43AYP
PLP34040U43AYP
Schneider Electric - Molded Case
PLP34040U43AYP, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 400A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, complete with fixed handle padlocking device, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
WLL1F320KA
WLL1F320KA
Siemens - Insulated Case
WLL1F320KA, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 2000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU725 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 600A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SEHF363200LSIGES3D5
SEHF363200LSIGES3D5
Square D - Insulated Case
SEHF363200LSIGES3D5, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0322NMNANENRMCX
MDN4083LEA0322NMNANENRMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNANENRMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSB1G232B
SSB1G232B
General Electric - Insulated Case
SSB1G232B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, modbus communication & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNC4YNRNSX
MDN4083LEA0822NMNC4YNRNSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4YNRNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEF361400LSA8
SEF361400LSA8
Schneider Electric - Insulated Case
SEF361400LSA8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1400A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, complete with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SSF1G367I
SSF1G367I
General Electric - Insulated Case
SSF1G367I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB4G699W
SSB4G699W
General Electric - Insulated Case
SSB4G699W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communcation, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNJNENANPX
MDN4083LEA0622NMNJNENANPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJNENANPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
NZMH3-4-VE630/400-AVE
NZMH3-4-VE630/400-AVE
Klockner Moeller - Molded Case
NZMH3-4-VE630/400-AVE, Eaton, Klockner Moeller, NZM3 Series, type , 4P, 3PH, 690V, 630A, 150kA@415V, high switching capacity, Draw-Out/withdrawable unit, Thermal Magnetic, molded case circuit breakers, IEC rated/UL listed
From Get Price
Limited Stock
SEF36200LIGES6E5
SEF36200LIGES6E5
Square D - Insulated Case
SEF36200LIGES6E5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
E3N-A20-4P-1000A-DO-MO-LSI
E3N-A20-4P-1000A-DO-MO-LSI
ABB - Insulated Case
E3N-A20-4P-1000A-DO-MO-LSI, ABB, EMax, type , 4P, 3PH, 2000A frame, 1000A rating plug, 600V, 50kA@480V, Draw-Out, manually operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SEHD36400LSGT1
SEHD36400LSGT1
Square D - Insulated Case
SEHD36400LSGT1, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 120VAC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHF36400LIGES7D8
SEHF36400LIGES7D8
Square D - Insulated Case
SEHF36400LIGES7D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
B1A1D0.5R
B1A1D0.5R
Noark Electric - Molded Case
B1A1D0.5R, Noark Electric, UL 489, type , PH, 1P, 240VDC, 0.5A, 10kA@60V, Feed-Thru ring tongue terminals, D trip curve, Thermal Magnetic, din rail mounted molded case circuit breakers
From Get Price