1. Home / 
  2. breaker

SORT BY
Limited Stock
LGU425035GVH09
LGU425035GVH09
Cutler Hammer - Molded Case
LGU425035GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 250A, 600V, 150kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip, LSG - Long-Time, Short-Time and Ground Fault trip functions and line & load side lug terminals, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
WLH1F312AG
WLH1F312AG
Siemens - Insulated Case
WLH1F312AG, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SED361800LSIT1
SED361800LSIT1
Schneider Electric - Insulated Case
SED361800LSIT1, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1800A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, complete with 120VAC shunt trip & 120VAC undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PGM36040U63AE1AC
PGM36040U63AE1AC
Square D - Molded Case
PGM36040U63AE1AC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with 3A/3B auxiliary switch, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and line side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNK2NNRCWX
MDN4083LEA0522NMNK2NNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK2NNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNE2ENKDWX
MDN4083LEA0322NMNE2ENKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE2ENKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SEHF36200LSIGES6F8
SEHF36200LSIGES6F8
Square D - Insulated Case
SEHF36200LSIGES6F8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 200A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NLCX4NNNNAX
MDN4083LEA0122NLCX4NNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NLCX4NNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, electrically operated with 24Vdc motor operator and 24Vdc spring release device (SRD), complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch & mechanical trip indicator, interchangeable Digitrip 220, LI - Long Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNNNENLCSX
MDN4083LEA0622NMNNNENLCSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNNNENLCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
E1X1RA
E1X1RA
Cutler Hammer - Auxiliary
E1X1RA, Cutler Hammer, Series C, auxiliary, 1A/1B, 125V, 50/60 switch for use in electronic circuit of 100 micro-amp and 15 Vdc minimum, right side mounted, 18-inch pigtail leads on same side, suitable for use with FDB,FD,HFD,FDC,FG,E2F,E2FM frame and F-frame HMCP molded case circuit breakers
From Get Price
Limited Stock
SED362000LSES6D4
SED362000LSES6D4
Square D - Insulated Case
SED362000LSES6D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
FNT408416HSF2ANFT
FNT408416HSF2ANFT
General Electric - Part And Accessory
FNT408416HSF2ANFT, General Electric, EntellEon, type , panelboard front, Type 1 non-vented, bottom, 40 enclosure width
From Get Price
Limited Stock
MDN4083LEA0122NMNK4ENRMAX
MDN4083LEA0122NMNK4ENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK4ENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
LGC360033WVH08
LGC360033WVH08
Cutler Hammer - Molded Case
LGC360033WVH08, Cutler Hammer, Series G, type , 3P, 3PH, 600A, 600V, 100kA@480V, current limiting, for Marine applications 50°C, not UL listed, Bolt-On, complete with interchangeable trip, LS - Long-Time and Short-Time trip functions, lugs not included, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNX4YNYCPX
MDN4083LEA0722NMNX4YNYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4YNYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
B216LSHGDMR
B216LSHGDMR
General Electric - Trip Units And Programmers
B216LSHGDMR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 1600A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, high range instantaneous, ground fault defeatable, trip functions, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
SED363200ES1E4
SED363200ES1E4
Square D - Insulated Case
SED363200ES1E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SSD1G3H3N
SSD1G3H3N
General Electric - Insulated Case
SSD1G3H3N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & relays features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF2G5H7Q
SSF2G5H7Q
General Electric - Insulated Case
SSF2G5H7Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & relays features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNNNENCNSX
MDN4083LEA0322NMNNNENCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNNNENCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, upper terminal voltage connection, Castell keylock, Solid State, low voltage power insulated case circuit breakers, shipped as drawout ACB in narrow cassette, with shutters, unwired
From Get Price
Limited Stock
SED361200LSIES2D5
SED361200LSIES2D5
Square D - Insulated Case
SED361200LSIES2D5, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHB5G8X42
SHB5G8X42
General Electric - Insulated Case
SHB5G8X42, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122CNAF4YNNNAX
MDN4083LEA0122CNAF4YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122CNAF4YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 24Vdc shunt trip (ST), 220-250Vdc UVR, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, electrically operated with factory installed 110-120Vac motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSF1G3M1L
SSF1G3M1L
General Electric - Insulated Case
SSF1G3M1L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price