1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0822NMNANNNNCPX
MDN4083LEA0822NMNANNNNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNANNNNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHB5G8B6U
SHB5G8B6U
General Electric - Insulated Case
SHB5G8B6U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E6V-A50-3P-5000A-DO-EO-LSIG
E6V-A50-3P-5000A-DO-EO-LSIG
ABB - Insulated Case
E6V-A50-3P-5000A-DO-EO-LSIG, ABB, EMax, type , 3P, 3PH, 5000A frame, 5000A rating plug, 600V, 125kA@480V, Draw-Out, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
AKRU-7B-30
AKRU-7B-30
General Electric - Air
AKRU-7B-30, General Electric, AKR Series, type , fused 800A frame, accepts NEMA fuse class L fuses, 3PH, 3P, 600V, 150A, 400A, or 800A sensor rating available, 200kA@600V, Draw-Out with substructure, available either mechanically operated or electrically operated, with MicroVersaTrip RMS-9 Solid State programmer, LI - Long-Time and Instantaneous trip functions, optional functions available, low voltage power air circuit breakers
From Get Price
Limited Stock
CJ2A225
CJ2A225
ITE - Molded Case
CJ2A225, ITE, Cordon, type , 2P, 1PH, 225A, 600V, 200kA@480V, Magnetic Only, I - Instantaneous protection only, 960-2000A magnetic range, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNR4YNYDAX
MDN4083LEA0422NMNR4YNYDAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNR4YNYDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNK2YHNNAX
MDN4083LEA0222NMNK2YHNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK2YHNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNK2NNKCWX
MDN4083LEA0222NMNK2NNKCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK2NNKCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNXNYNKMWX
MDN4083LEA0222NMNXNYNKMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNXNYNKMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNA2YHNCCX
MDN4083LEA0522NMNA2YHNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA2YHNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNF4ENRMAX
MDN4083LEA0822NMNF4ENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF4ENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNJ4YNNNAX
MDN4083LEA0422NMNJ4YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNJ4YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNC4NNHNAX
MDN4083LEA0522NMNC4NNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC4NNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNC2YNANAX
MDN4083LEA0222NMNC2YNANAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNC2YNANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNJ2YNHDPX
MDN4083LEA0422NMNJ2YNHDPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNJ2YNHDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHF5G8J8W
SHF5G8J8W
General Electric - Insulated Case
SHF5G8J8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MP2110KMAS
MP2110KMAS
Murray Corporation - Molded Case
MP2110KMAS, Murray Corporation, MP Series, type , 2P, 1PH, 110A, 120/240V, 65kA@240V, high interrupting capacity, 40°C, Plug-In, common trip, complete with 1A/1B 120V auxiliary switch, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNK4YNYCAX
MDN4083LEA0822NMNK4YNYCAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK4YNYCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNRNENADAX
MDN4083LEA0622NMNRNENADAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNRNENADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNC4YCNCCX
MDN4083LEA0822NMNC4YCNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4YCNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSB2G5N4U
SSB2G5N4U
General Electric - Insulated Case
SSB2G5N4U, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
WLH1D316FN
WLH1D316FN
Siemens - Insulated Case
WLH1D316FN, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 1600A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU748 programmer + WLLCD48 LCD display + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 350A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNGNNNKDSX
MDN4083LEA0722NMNGNNNKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNGNNNKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
EEEDH360125SB2
EEEDH360125SB2
Cutler Hammer - Mounting Hardware
EEEDH360125SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 125A, ABC phase connection, 600V max, Copper, Single Branch mounting style, suitable for use with ED,EDH,EDC,JD,HJD,JDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price