1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MPA41F16W0027
MPA41F16W0027
General Electric - Insulated Case
MPA41F16W0027, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 48V dc shunt trip and 380/440V ac undervoltage trip with delay, 4P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
B216LSIGZ2PMR
B216LSIGZ2PMR
General Electric - Trip Units And Programmers
B216LSIGZ2PMR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 1600A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, short-time selective interlock, protective relays, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
SHF3G6B7U
SHF3G6B7U
General Electric - Insulated Case
SHF3G6B7U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
WLS1F312QH
WLS1F312QH
Siemens - Insulated Case
WLS1F312QH, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1200A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLLCD48 LCD display + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 1200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SPB150-3P-800A-EO-DO-LI
SPB150-3P-800A-EO-DO-LI
Cutler Hammer - Insulated Case
SPB150-3P-800A-EO-DO-LI, Cutler Hammer, Systems Pow-R, type , 800A frame size, 3P, 3PH, 800A, 600V, 150kA@480V, standard interrupting capacity, Draw-Out, electrically operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LI - Long-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
SSB4G6H6N
SSB4G6H6N
General Electric - Insulated Case
SSB4G6H6N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering, RELT, modbus communication & relays features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNJ2ENNNPX
MDN4083LEA0222NMNJ2ENNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNJ2ENNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHD1G237E
SHD1G237E
General Electric - Insulated Case
SHD1G237E, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 250A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
WLH1F308FQ
WLH1F308FQ
Siemens - Insulated Case
WLH1F308FQ, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 800A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU748 programmer+ WLLCD48 LCD display + WLGFM48 ground fault module, LSG - Long-Time, Short-Time and Ground Fault trip functions and 350A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SSF2G5L3N
SSF2G5L3N
General Electric - Insulated Case
SSF2G5L3N, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNH4YNCDPX
MDN4083LEA0222NMNH4YNCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4YNCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNF4YNRNAX
MDN4083LEA0122NMNF4YNRNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF4YNRNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNG2YNYMPX
MDN4083LEA0722NMNG2YNYMPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG2YNYMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNN4NNKMPX
MDN4083LEA0322NMNN4NNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN4NNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
WLS2F320NL
WLS2F320NL
Siemens - Insulated Case
WLS2F320NL, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 2000A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLGFA48 ground fault module, LSGA - Long-Time, Short-Time and Ground Fault Alarm trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNR2YNHMSX
MDN4083LEA0522NMNR2YNHMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2YNHMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
AQB-A51-50
AQB-A51-50
Eaton - Molded Case
AQB-A51-50, Eaton, Naval, type , 3P, 3PH, 50A, 500Vac, 5kA@500V, 50°C, Plug-In, enhanced overcurrent protection features, non-interchangeable trip, Thermal Magnetic, molded case circuit breakers for naval shipboard use
From Get Price
Limited Stock
K600-EO-DO-LSIG
K600-EO-DO-LSIG
ABB - Air
K600-EO-DO-LSIG, ABB, K-Line, type , 600A frame size, electrically operated/Draw-Out, 3P, 3PH, 600A, 600V, 30kA@480V, originally supplied with OD electro-mechanical overcurrent trip device, SS, MPS or MPS-C trip device but can also be retrofitted with a modern Solid State electronic trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
EEEHD240015SB2
EEEHD240015SB2
Cutler Hammer - Mounting Hardware
EEEHD240015SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 15A, AC phase connection, 480V max, Copper, Single Branch mounting style, suitable for use with EHD,FDB,FD,HFD,FDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
SSF4G7Q41
SSF4G7Q41
General Electric - Insulated Case
SSF4G7Q41, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNXNENCCCX
MDN4083LEA0622NMNXNENCCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNXNENCCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PEBC4ATEJ0025
PEBC4ATEJ0025
General Electric - Molded Case
PEBC4ATEJ0025, General Electric, GuardEon, type , 3PH, 4P, 600V, 8-25A, 25kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MPA31F1600120
MPA31F1600120
General Electric - Insulated Case
MPA31F1600120, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 24/30V dc closing coil and 48V dc shunt trip, 3P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNHNNCNCPX
MDN4083LEA0722NMNHNNCNCPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNHNNCNCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price