Limited Stock
SSB3G651N
SSB3G651N
General Electric - Insulated Case
SSB3G651N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, RELT, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG32K0600D4YN
PDG32K0600D4YN
Eaton - Molded Case
PDG32K0600D4YN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 600A, 50kA@480V, Bolt-On, no lug terminals, complete with PXR20D ARMS trip with LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU, CAM Link, ZSI & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SHD4G6F9N
SHD4G6F9N
General Electric - Insulated Case
SHD4G6F9N, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PEAN4ATAL0150
PEAN4ATAL0150
General Electric - Molded Case
PEAN4ATAL0150, General Electric, GuardEon, type , 3PH, 4P, 600V, 45-150A, 65kA@480V, front connection/Feed-Thru, toggle mechanism, complete with PremEon G interchangeable trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
11115L
11115L
Bulldog - Molded Case
11115L, Bulldog, 1P, 1PH, 15A, 120V, 10kA@120V, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNJNENANSX
MDN4083LEA0122NMNJNENANSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJNENANSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNG4ECNMSX
MDN4083LEA0422NMNG4ECNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG4ECNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MP50-3P-5000A-MO-BO-LSI
MP50-3P-5000A-MO-BO-LSI
Merlin Gerin - Insulated Case
MP50-3P-5000A-MO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
PDG32N0400D4MK
PDG32N0400D4MK
Eaton - Molded Case
PDG32N0400D4MK, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 400A, 85kA@480V, Bolt-On, line side lug terminals, complete with PXR20D ARMS trip with LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0122NMNNNNNANSX
MDN4083LEA0122NMNNNNNANSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNNNANSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNC2YHNNWX
MDN4083LEA0122NMNC2YHNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2YHNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNKNENAMPX
MDN4083LEA0722NMNKNENAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNKNENAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNA2ENYCWX
MDN4083LEA0222NMNA2ENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA2ENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNC2YNYMSX
MDN4083LEA0722NMNC2YNYMSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC2YNYMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PEEN2ATEL0125
PEEN2ATEL0125
General Electric - Molded Case
PEEN2ATEL0125, General Electric, GuardEon, type , 1PH, 2P in 3P construction, 600V, 38-125A, 65kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MDN4083LEA0722NMNANNNNNWX
MDN4083LEA0722NMNANNNNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNANNNNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNN4ENCCWX
MDN4083LEA0222NMNN4ENCCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN4ENCCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNG4EHNMPX
MDN4083LEA0622NMNG4EHNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG4EHNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNHNNNAMCX
MDN4083LEA0622NMNHNNNAMCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNHNNNAMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
AK-3A-100
AK-3A-100
General Electric - Air
AK-3A-100, General Electric, AK Series, type , 3P, 3PH, 4000A sensor rating, 600V, 100kA@480V, electrically or manually operated, AKD-5 Draw-Out, with Power Sensor trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNK2ENYDWX
MDN4083LEA0422NMNK2ENYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK2ENYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHD1G1C6A
SHD1G1C6A
General Electric - Insulated Case
SHD1G1C6A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering & modbus communication features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNENYNHNAX
MDN4083LEA0322NMNENYNHNAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNENYNHNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNJ4ENNCAX
MDN4083LEA0122NMNJ4ENNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJ4ENNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price