1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
LV431771ATS4
LV431771ATS4
Schneider Electric - Molded Case
LV431771ATS4, Schneider Electric, Compact NSX, type , 3P, 3PH, 250A, 690V, 36kA@415V, Bolt-On, complete with NSX250F frame, type UA, 380Vac controller, automatic transfer switch and 3 pole, 160A Micrologic 2.2 trip unit with LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122CMNKNNNNNAX
MDN4083LEA0122CMNKNNNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122CMNKNNNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 24Vdc shunt trip (ST), 600Vac UVR & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PDF54P0800D4DN
PDF54P0800D4DN
Cutler Hammer - Molded Case
PDF54P0800D4DN, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 800A, 100kA@480V, Bolt-On, no terminals, complete with PXR20D trip with LSI - Long-Time, Short-Time and Instantaneous trip with ARMS functions with relays, modbus & CAM option, Solid State electronic, molded case circuit breakers; globally rated with 100% UL rating
From Get Price
Limited Stock
PKP36025CU74BE1AA
PKP36025CU74BE1AA
Schneider Electric - Molded Case
PKP36025CU74BE1AA, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B auxiliary switch, micrologic interchangeable harmonic 6.0H trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
706749-T12
706749-T12
ABB - Shunt Trip
706749-T12, ABB, BBC, ITE, K-Line, Shunt Trip/Close Coil Assembly, 250VDC, 500/600VAC, suitable for All K-3000/K-4000
From Get Price
Limited Stock
QDM22100TN
QDM22100TN
Schneider Electric - Molded Case
QDM22100TN, Square D, Schneider Electric, PowerPact, type , 2P, 1PH, 100A, 240V, 25kA@240V, UL listed, standard interrupting capacity, Bolt-On, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNANYNRCAX
MDN4083LEA0622NMNANYNRCAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNANYNRCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNH2EHNMPX
MDN4083LEA0822NMNH2EHNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2EHNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
In Stock
HJL36050ABBEUS
HJL36050ABBEUS
Square D - Molded Case
HJL36050ABBEUS, Square D, PowerPact, type , 3P, 3PH, 50A, 600V, 65kA@480V, UL listed, current limiting, Feed-Thru, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch and overcurrent trip switch, 250 VDC under voltage release (UVR), molded case circuit breakers
From $1,447.32
Limited Stock
NT06L-3P-FIXED
NT06L-3P-FIXED
Square D - Insulated Case
NT06L-3P-FIXED, Square D, Schneider Electric, Masterpact, type , T-Frame, 3P, 3PH, 600A, 600V, 100kA@480V, very high interrupting capacity, Bolt-On, complete with Micrologic trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, Universal Power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNF4NNYCCX
MDN4083LEA0122NMNF4NNYCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNF4NNYCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
In Stock
HJL36080BESN
HJL36080BESN
Square D - Molded Case
HJL36080BESN, Square D, PowerPact, type , 3P, 3PH, 80A, 600V, 65kA@480V, UL listed, current limiting, Feed-Thru, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with alarm switch and overcurrent trip switch, 12 VDC shunt trip, molded case circuit breakers
From $1,464.12
Limited Stock
MDN4083LEA0222NMNN2NHNMPX
MDN4083LEA0222NMNN2NHNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNN2NHNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
In Stock
HLA36150U31XAEBKSD
HLA36150U31XAEBKSD
Square D - Molded Case
HLA36150U31XAEBKSD, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 100kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 208/277 VAC shunt trip, molded case circuit breakers
From $3,933.44
In Stock
HDA260601AEBESKYP
HDA260601AEBESKYP
Square D - Molded Case
HDA260601AEBESKYP, Square D, PowerPact, type , 2P, A & B phase connection, 1PH, 60A, 600V, 18kA@480V, UL listed, standard interrupting capacity, I-Line Style Plug-In, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, 24 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,624.66
Limited Stock
SED363000LSIGES7B8
SED363000LSIGES7B8
Schneider Electric - Insulated Case
SED363000LSIGES7B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
E3H-A08-4P-600A-BO-MO-LI
E3H-A08-4P-600A-BO-MO-LI
ABB - Insulated Case
E3H-A08-4P-600A-BO-MO-LI, ABB, EMax, type , 4P, 3PH, 800A frame, 600A rating plug, 600V, 85kA@480V, fixed mount/Bolt-On, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
E3S-A20-3P-600A-BO-MO-LSI
E3S-A20-3P-600A-BO-MO-LSI
ABB - Insulated Case
E3S-A20-3P-600A-BO-MO-LSI, ABB, EMax, type , 3P, 3PH, 2000A frame, 600A rating plug, 600V, 65kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0622NMNX4NNCNPX
MDN4083LEA0622NMNX4NNCNPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX4NNCNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
In Stock
SHND69800AG
SHND69800AG
Siemens - Molded Case
SHND69800AG Siemens Sentron Series, type , 3P, 3PH, 800A, 600V, 65kA@480V, high interrupting capacity, Bolt-On, complete with LIG, LIG - Long-Time, Instantaneous and Ground Fault trip functions, lugs not included, acceptable for reverse connection application, Digital Solid State Electronic molded case circuit breakers
From $7,857.61
Limited Stock
MDN4083LEA0222NMNGNEMNCWX
MDN4083LEA0222NMNGNEMNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNGNEMNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
PJF36100CU43ABC
PJF36100CU43ABC
Schneider Electric - Molded Case
PJF36100CU43ABC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B alarm switch, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNRNNNNMWX
MDN4083LEA0822NMNRNNNNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNRNNNNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNG4ENRDWX
MDN4083LEA0422NMNG4ENRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG4ENRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price