MDN4083LEA0122HNAHNYNNNAX
MDN4083LEA0122HNAHNYNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122HNAHNYNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 48Vdc shunt trip (ST), 48Vdc UVR, mechanical trip indicator & OTS switch, electrically operated with factory installed 110-120Vac motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNHNENHCWX
MDN4083LEA0522NMNHNENHCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNHNENHCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC4YNHNPX
MDN4083LEA0122NMNC4YNHNPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC4YNHNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNNNENADCX
MDN4083LEA0522NMNNNENADCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNNNENADCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, latch check switch for external wiring, operations counter, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, without shutters and unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNH4NNKMPX
MDN4083LEA0822NMNH4NNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH4NNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNA2NNKDCX
MDN4083LEA0422NMNA2NNKDCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2NNKDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
EELCL510175SB2
EELCL510175SB2
Cutler Hammer - Mounting Hardware
EELCL510175SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 175A, BCL or ABR phase connection, 120V max, Copper, Single Branch mounting style, suitable for use with LCL circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
PEDL4ATEJ0125
PEDL4ATEJ0125
General Electric - Molded Case
PEDL4ATEJ0125, General Electric, GuardEon, type , 3PH, 4P, 600V, 38-125A, 150kA@480V, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
PB31800V
PB31800V
Westinghouse - Insulated Case
PB31800V, Eaton, Cutler Hammer, Westinghouse, PB Series, type , 3P, 3PH, 1800A, 600V, 100kA@480V, Bolt-On, complete with interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNRNNNRNPX
MDN4083LEA0722NMNRNNNRNPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNRNNNRNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
WLL2F325TG
WLL2F325TG
Siemens - Insulated Case
WLL2F325TG, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 2500A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 1600A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SHF6G9N72
SHF6G9N72
General Electric - Insulated Case
SHF6G9N72, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNRNYNHMWX
MDN4083LEA0122NMNRNYNHMWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNRNYNHMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNFNNNKNWX
MDN4083LEA0622NMNFNNNKNWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNFNNNKNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
432321
432321
General Electric - Rating Plug
432321, General Electric, Record Plus, type , switchable rating plug element, rated for 160A, suitable for use with FE160- FEN,FEH,FEL molded case circuit breaker frame types, for use with SMR1 Selective solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNX2YNCDPX
MDN4083LEA0322NMNX2YNCDPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNX2YNCDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNH2ENACAX
MDN4083LEA0322NMNH2ENACAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH2ENACAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNCNENKCAX
MDN4083LEA0322NMNCNENKCAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNCNENKCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SSB3G6J3U
SSB3G6J3U
General Electric - Insulated Case
SSB3G6J3U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
THP1616SSE3
THP1616SSE3
General Electric - Insulated Case
THP1616SSE3, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 1600A current sensor rating, 1600A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 125Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, electrically operated with 120VAC electrical motor operator, Solid State electrical, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNR4ENCMWX
MDN4083LEA0122NMNR4ENCMWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNR4ENCMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0422NMNK2NNCDAX
MDN4083LEA0422NMNK2NNCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK2NNCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
LGH360033GVH09
LGH360033GVH09
Cutler Hammer - Molded Case
LGH360033GVH09, Cutler Hammer, Series G, type , 3P, 3PH, 600A, 600V, 65kA@480V, high interrupting capacity, for Naval applications 50°C, not UL listed, Feed-Thru, complete with interchangeable trip, LS - Long-Time and Short-Time trip functions and line & load side lug terminals, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNFNEMNNPX
MDN4083LEA0522NMNFNEMNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNFNEMNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired