Limited Stock
MDS6083WEA06CUNMNNNNNNNAX
MDS6083WEA06CUNMNNNNNNNAX
Eaton - Insulated Case
MDS6083WEA06CUNMNNNNNNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 600A rating plug, Non-DSL current limiter, 520MC LSI (120 Vac) trip unit, No shunt trip, Manual operated motor operator, No SRD, No, No auxiliary switch, No padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
MDS6083WEA081CAMNN4YNANAX
MDS6083WEA081CAMNN4YNANAX
Eaton - Insulated Case
MDS6083WEA081CAMNN4YNANAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 800A rating plug, Non-DSL current limiter, 1150 LSI (120 Vac) trip unit, 110-127 Vac/Vdc shunt trip, Manual operated motor operator, No SRD, No, 4A/4B auxiliary switch, No padlock, Counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
MDS6163WEA0652NMNN2NCANAX
MDS6163WEA0652NMNN2NCANAX
Eaton - Insulated Case
MDS6163WEA0652NMNN2NCANAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 1600A, 3-Pole, Drawout mounting, 600A rating plug, Non-DSL current limiter, 520 LSI trip unit, No shunt trip, Manual operated motor operator, No SRD, No, 2A/2B auxiliary switch, Metal (block close only) padlock, Counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
MWI8083LEA0852CMNN2NMNNAX
MWI8083LEA0852CMNN2NMNNAX
Eaton - Air
MWI8083LEA0852CMNN2NMNNAX, Cutler Hammer, Eaton, Magnum IEC Type , Standard frame, 85kV@690V interrupting rating, 800A, 3-Pole, Drawout Horizontal mounting, 800 rating plug, {current limiter} current limiter, 520 LSI trip unit, 24 Vdc shunt trip, Manual operated motor operator, No SRD, 2A/2B auxiliary switch, Metal (block close and open) padlock, No counter - no locks key lock, air circuit breaker
From Get Price
Limited Stock
AKRU-10D-50-MO-DO-LI
AKRU-10D-50-MO-DO-LI
General Electric - Air
AKRU-10D-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
21-B173LD6
21-B173LD6
Hardware Resource Company - Mounting Hardware
21-B173LD6, Hardware Resource Company, direct replacement mounting hardware strap kit for ITE/Siemens FC1,FCII,P5,S5,CDP5,CDP6,SB1,SB2,SB3,SPP,FPP,VB6 panel boards, rated for 600A 600V max, Copper, Single Branch mounting style, suitable for use with LD,LXD,HLD,HLXD,HHLD,HHLXD circuit breaker frames, complete with all associated hardware, screws and cover plates
From Get Price
Limited Stock
MDSC303WEA25CHCNAN6Y
MDSC303WEA25CHCNAN6Y
Eaton - Insulated Case
MDSC303WEA25CHCNAN6Y, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 3000A, 3-Pole, Drawout mounting, 2500A rating plug, Non-DSL current limiter, 520MC LSIG (24/48 Vdc) trip unit, 24 Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 6A/6B auxiliary switch, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
AKRU-8D-50-MO-DO-LI
AKRU-8D-50-MO-DO-LI
General Electric - Air
AKRU-8D-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
MDS6163WEA121ANMNN6NNNNAX
MDS6163WEA121ANMNN6NNNNAX
Eaton - Insulated Case
MDS6163WEA121ANMNN6NNNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 1600A, 3-Pole, Drawout mounting, 1200A rating plug, Non-DSL current limiter, 1150 LSI (24/48 Vdc) trip unit, No shunt trip, Manual operated motor operator, No SRD, No, 6A/6B auxiliary switch, No padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
MDS6323WEA3252NMNA2ENNNAX
MDS6323WEA3252NMNA2ENNNAX
Eaton - Insulated Case
MDS6323WEA3252NMNA2ENNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 2300A, 3-Pole, Drawout mounting, 3200A rating plug, Non-DSL current limiter, 520 LSI trip unit, No shunt trip, Manual operated motor operator, No SRD, UVR (110-127 Vac), 2A/2B auxiliary switch, No padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
In Stock
GTD-ZP1N0AE-400A-MO-3P
GTD-ZP1N0AE-400A-MO-3P
Cutler Hammer - Ground & Test Device
GTD-ZP1N0AE-400A-MO-3P, Cutler Hammer, ZP1N Series, , Manually Operated, 3PH, 3 Bushing Design, 5000 VAC, 400A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
AKRU-8A-50-MO-DO-LSG
AKRU-8A-50-MO-DO-LSG
General Electric - Air
AKRU-8A-50-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
MDSC163WEA1252NMNN6YPNNAX
MDSC163WEA1252NMNN6YPNNAX
Eaton - Insulated Case
MDSC163WEA1252NMNN6YPNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 1600A, 3-Pole, Drawout mounting, 1200A rating plug, Non-DSL current limiter, 520 LSI trip unit, No shunt trip, Manual operated motor operator, No SRD, No, 6A/6B auxiliary switch, Plastic (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
A72XM3EQ18FTCLP
A72XM3EQ18FTCLP
nVent Hoffman - Enclosure
A72XM3EQ18FTCLP, nVent Hoffman, Disconnect Enclosure, Mild Steel, Gray Powder Coat, NEMA Type 12. 72.12 inch H x 100.75 inch W x 18.12 inch D. Sequestr External Disconnect Enclosure Package. Shipped as one unit for new installations, the disconnect switch and fuse block/circuit breaker are mounted in the external enclosure, with terminal connections to bring power to the main enclosure.
From Get Price
Limited Stock
GTD-PV-M-1200A-MO-6P
GTD-PV-M-1200A-MO-6P
Powell - Ground & Test Device
GTD-PV-M-1200A-MO-6P, Powell, PowlVac Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
AKRU-8B-50-MO-DO-LSG
AKRU-8B-50-MO-DO-LSG
General Electric - Air
AKRU-8B-50-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
AKRU-8B-30-MO-DO-LSG
AKRU-8B-30-MO-DO-LSG
General Electric - Air
AKRU-8B-30-MO-DO-LSG, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
IVT-16-1200A-MO-6P
IVT-16-1200A-MO-6P
Siemens - Ground & Test Device
IVT-16-1200A-MO-6P, Siemens, VV Series, , Manually Operated, 3PH, 6 Bushing Design, 38000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In IV Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
AKRU-10A-50-MO-DO-LI
AKRU-10A-50-MO-DO-LI
General Electric - Air
AKRU-10A-50-MO-DO-LI, General Electric, Manually Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, with MicroVersa Trip Plus - Gen 2 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price
Limited Stock
MDSC4N3HEA405GNMNN4ENNNBX
MDSC4N3HEA405GNMNN4ENNNBX
Eaton - Insulated Case
MDSC4N3HEA405GNMNN4ENNNBX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 4000A, 3-Pole, Fixed horizonal mounting, 4000A rating plug, Non-DSL current limiter, 520 LSIG trip unit, No shunt trip, Manual operated motor operator, No SRD, No, 4A/4B auxiliary switch, No padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
MDS6323VEA305GNMNNNNMNNAX
MDS6323VEA305GNMNNNNMNNAX
Eaton - Insulated Case
MDS6323VEA305GNMNNNNMNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 2300A, 3-Pole, Fixed vertical mounting, 3000A rating plug, Non-DSL current limiter, 520 LSIG trip unit, No shunt trip, Manual operated motor operator, No SRD, No, No auxiliary switch, Metal (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
In Stock
JJA36250U33X
JJA36250U33X
Square D - Molded Case
JJA36250U33X, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 250A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, complete with micrologic standard 3.2S non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breaker
From $2,206.01
Limited Stock
LE3250U31X
LE3250U31X
Square D - Trip Units And Programmers
LE3250U31X, Square D, PowerPact, type , interchangeable micrologic standard 3.3 trip unit with LI, LI - Long-Time and Instantaneous trip functions, rated for 70A, suitable for L Frame 250A- LDA,LDF,LDL,LDM,LDP,LDN,LDD,LDS,LGA,LGF,LGL,LGM,LGP,LGN,LGD,LGS,LJA,LJF,LJM,LJP,LJN,LJS,LLA,LLF,LLL,LLM,LLP,LLN,LLD,LLS,LRA,LRL,LRM,LRP,LRF molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price
Limited Stock
LE4250U31X
LE4250U31X
Square D - Trip Units And Programmers
LE4250U31X, Square D, PowerPact, type , 4P interchangeable micrologic standard 3.3 trip unit with LI - Long-Time and Instantaneous trip functions, rated for 70A, suitable for L Frame 250A- LDA,LDF,LDL,LDM,LDP,LDN,LDD,LDS,LGA,LGF,LGL,LGM,LGP,LGN,LGD,LGS,LJA,LJF,LJM,LJP,LJN,LJS,LLA,LLF,LLL,LLM,LLP,LLN,LLD,LLS,LRA,LRL,LRM,LRP,LRF molded case circuit breaker frame types, Solid State electronic trip units and programmers & circuit breakers
From Get Price