AKR-11A-30-EO-DO-LI
AKR-11A-30-EO-DO-LI
General Electric - Air
AKR-11A-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MDSC163WEA1652NMNH6NHNNAX
MDSC163WEA1652NMNH6NHNNAX
Eaton - Insulated Case
MDSC163WEA1652NMNH6NHNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 1600A, 3-Pole, Drawout mounting, 1600A rating plug, Non-DSL current limiter, 520 LSI trip unit, No shunt trip, Manual operated motor operator, No SRD, UVR (48 Vdc), 6A/6B auxiliary switch, Plastic (block close only) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
MDSC4N3WEA405GAMNN2ECNNAX
MDSC4N3WEA405GAMNN2ECNNAX
Eaton - Insulated Case
MDSC4N3WEA405GAMNN2ECNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 4000A, 3-Pole, Drawout mounting, 4000A rating plug, Non-DSL current limiter, 520 LSIG trip unit, 110-127 Vac/Vdc shunt trip, Manual operated motor operator, No SRD, No, 2A/2B auxiliary switch, Metal (block close only) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
AKR-11S-30H-EO-BI-LI
AKR-11S-30H-EO-BI-LI
General Electric - Air
AKR-11S-30H-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MDS6083WEA085GCNAN2YNNNAX
MDS6083WEA085GCNAN2YNNNAX
Eaton - Insulated Case
MDS6083WEA085GCNAN2YNNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 800A rating plug, Non-DSL current limiter, 520 LSIG trip unit, 24 Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 2A/2B auxiliary switch, No padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
AKR-4S-30-EO-BI-LI
AKR-4S-30-EO-BI-LI
General Electric - Air
AKR-4S-30-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
AKR-4S-50H-EO-BI-LI
AKR-4S-50H-EO-BI-LI
General Electric - Air
AKR-4S-50H-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
AKR-5AE-30-EO-DO-LI
AKR-5AE-30-EO-DO-LI
General Electric - Air
AKR-5AE-30-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
AKRT-5B-50H-EO-DO-LI
AKRT-5B-50H-EO-DO-LI
General Electric - Air
AKRT-5B-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
Limited Stock
MDS6083WEA08MMNMNNNNMNNAX
MDS6083WEA08MMNMNNNNMNNAX
Eaton - Insulated Case
MDS6083WEA08MMNMNNNNMNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 65kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 800A rating plug, Non-DSL current limiter, 520M LSIG (120 Vac) trip unit, No shunt trip, Manual operated motor operator, No SRD, No, No auxiliary switch, Metal (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price
Limited Stock
AKR-4A-50-EO-DO-LI
AKR-4A-50-EO-DO-LI
General Electric - Air
AKR-4A-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price
In Stock
GTD-VCP-T-67A3056G02-2000A-MO-6P
GTD-VCP-T-67A3056G02-2000A-MO-6P
Eaton - Ground & Test Device
GTD-VCP-T-67A3056G02-2000A-MO-6P, Eaton, VCP-T Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 2000A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-5-HK-1200A-MO-6P
GTD-5-HK-1200A-MO-6P
ITE - Ground & Test Device
GTD-5-HK-1200A-MO-6P, ITE, HK Series, , Manually Operated, 3PH, 6 Bushing Design, 5000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In HK Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-15-HK-1200A-MO-6P
GTD-15-HK-1200A-MO-6P
ITE - Ground & Test Device
GTD-15-HK-1200A-MO-6P, ITE, HK Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In HK Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-15-HK-1200A-MO-3P
GTD-15-HK-1200A-MO-3P
ITE - Ground & Test Device
GTD-15-HK-1200A-MO-3P, ITE, HK Series, , Manually Operated, 3PH, 3 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In HK Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-AM-150D-1200A-MO-6P
GTD-AM-150D-1200A-MO-6P
Allis Chalmers - Ground & Test Device
GTD-AM-150D-1200A-MO-6P, Allis Chalmers, Ruptair Series, , Manually Operated, 3PH, 6 Bushing Design, 5000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In Ruptair Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-5-HK-1200A-EO-6P
GTD-5-HK-1200A-EO-6P
ITE - Ground & Test Device
GTD-5-HK-1200A-EO-6P, ITE, HK Series, , Electrically Operated, 3PH, 6 Bushing Design, 5000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In HK Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-5-HK-1200A-MO-3P
GTD-5-HK-1200A-MO-3P
ITE - Ground & Test Device
GTD-5-HK-1200A-MO-3P, ITE, HK Series, , Manually Operated, 3PH, 3 Bushing Design, 5000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In HK Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-ADVAC-1200-2000A-MO-6P
GTD-ADVAC-1200-2000A-MO-6P
ABB - Ground & Test Device
GTD-ADVAC-1200-2000A-MO-6P, ABB, ADVAC Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, A Frame, circuit breaker ground & test device, For Use In ADVANCE Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-38-HKV-1200A-EO-6P
GTD-38-HKV-1200A-EO-6P
ITE - Ground & Test Device
GTD-38-HKV-1200A-EO-6P, ITE, HKV Series, , Electrically Operated, 3PH, 6 Bushing Design, 34500 VAC, 1200A Frame, circuit breaker ground & test device, For Use In 38HKV Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-DZ-60A-600A-MO-3P
GTD-DZ-60A-600A-MO-3P
Allis Chalmers - Ground & Test Device
GTD-DZ-60A-600A-MO-3P, Allis Chalmers, DZ Series, , Manually Operated, 3PH, 3 Bushing Design, 15000 VAC, 600A Frame, circuit breaker ground & test device, For Use In Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
PVV-1200-2000-10-1200-2000A-MO-6P
PVV-1200-2000-10-1200-2000A-MO-6P
General Electric - Ground & Test Device
PVV-1200-2000-10-1200-2000A-MO-6P, General Electric, PowerVac, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, A Frame, circuit breaker ground & test device, For Use In PowerVac Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
PVV-3000-3000A-EO-6P
PVV-3000-3000A-EO-6P
General Electric - Ground & Test Device
PVV-3000-3000A-EO-6P, General Electric, PowerVac, , Electrically Operated, 3PH, 6 Bushing Design, 15000 VAC, 3000A Frame, circuit breaker ground & test device, For Use In PowerVac Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price
Limited Stock
GTD-K-600-600A-MO-6P
GTD-K-600-600A-MO-6P
ABB - Ground & Test Device
GTD-K-600-600A-MO-6P, ABB, K-Line Series, , Manually Operated, 3PH, 6 Bushing Design, 600 VAC, 600A Frame, circuit breaker ground & test device, For Use In K-Line Series Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price