


- Home /
breaker
911,476 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0322NMNG2YNKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG2YNKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SEHD36600LSGF4
Schneider Electric - Insulated Case
SEHD36600LSGF4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, complete with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

B440LIGDM
General Electric - Trip Units And Programmers
B440LIGDM, General Electric, MicroVersaTrip PM, type , trip units and programmers, 4000A current sensor rating, Solid State electronic, LIG - Long-Time, Instantaneous and Ground Fault, ground fault defeatable, trip functions, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price

PLP34000S12AB
Square D - Molded Case
PLP34000S12AB, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1200A, 480V, 100kA@480V, very UL listed, high interrupting capacity, Bolt-On, complete with 2A/2B auxiliary switch, NA - No Overcurrent Protection, Non-Automatic switch, load side lug terminals, molded case circuit breakers
From Get Price

MDN4083LEA0422NMNC2NNHCPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC2NNHCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0222NMNE2ENRCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE2ENRCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

WLL2F308NE
Siemens - Insulated Case
WLL2F308NE, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 800A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MN32M32
General Electric - Insulated Case
MN32M32, General Electric, M-PACT Plus, type , frame size 2, manually operated, without cassette, moving portion only, 5 N.O.-3 N.C. Auxiliary switch, 3P, 3PH, 3200A, 690V, 65kA@415V, Draw-Out, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price

SSF5G837U
General Electric - Insulated Case
SSF5G837U, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

PEBB3ATTN0040
General Electric - Molded Case
PEBB3ATTN0040, General Electric, GuardEon, type , 3PH, 3P, 600V, 40A, 18kA@480V, 100% rated, front connection/Feed-Thru, toggle mechanism, complete with LTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price

SSF6G9941
General Electric - Insulated Case
SSF6G9941, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication, relays & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SED36250ES3D4
Square D - Insulated Case
SED36250ES3D4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0822NMNA2NNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2NNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

PKL36120U44BAB
Schneider Electric - Molded Case
PKL36120U44BAB, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 600V, 50kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with 2A/2B auxiliary switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

THS203LD14
General Electric - Insulated Case
THS203LD14, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1400A, 150kA@480V, standard interrupting capacity, Feed-Thru, manually operated, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4200-11,200A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

SED36300LSGES1E4
Square D - Insulated Case
SED36300LSGES1E4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

E6H-A40-4P-3000A-BO-MO-LSIG
ABB - Insulated Case
E6H-A40-4P-3000A-BO-MO-LSIG, ABB, EMax, type , 4P, 3PH, 4000A frame, 3000A rating plug, 600V, 85kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price

KHL360701212
Square D - Molded Case
KHL360701212, Square D, KHL Series, type , 3P, 3PH, 70A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, complete with 1A/1B aux switch, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price

MDN4083LEA0322NMNR4YCNMAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNR4YCNMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0622NMNF4YNCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF4YNCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price

SSD1G354H
General Electric - Insulated Case
SSD1G354H, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

WLL1D308DU
Siemens - Insulated Case
WLL1D308DU, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 800A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFM76 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 300A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price

MDN4083LEA0222NMNX2NNLNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX2NNLNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

FHL360502100
Square D - Molded Case
FHL360502100, Square D, FHL Series, type , 3P, 3PH, 50A, 600V, 25kA@480V, standard interrupting capacity, Feed-Thru, complete with 1A 250Vac/28Vdc alarm switch, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price