1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
WLL2F330BD
WLL2F330BD
Siemens - Insulated Case
WLL2F330BD, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 3000A, 600V, 100kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLLCD48 LCD display, LSI - Long-Time, Short-Time and Instantaneous trip functions and 225A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SED36350ES3
SED36350ES3
Square D - Insulated Case
SED36350ES3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 350A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD364000ES4D4
SEHD364000ES4D4
Square D - Insulated Case
SEHD364000ES4D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEF361600ES7B8
SEF361600ES7B8
Schneider Electric - Insulated Case
SEF361600ES7B8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNJNYNLNPX
MDN4083LEA0422NMNJNYNLNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNJNYNLNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch, & Castell key interlock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
NPGP36040CU33B
NPGP36040CU33B
Schneider Electric - Molded Case
NPGP36040CU33B, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, 100% rated, complete with micrologic interchangeable standard 5.0 trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SSD4G6E3P
SSD4G6E3P
General Electric - Insulated Case
SSD4G6E3P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT & modbus communication features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED364000ES9A4
SED364000ES9A4
Square D - Insulated Case
SED364000ES9A4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNA2ENNMWX
MDN4083LEA0422NMNA2ENNMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2ENNMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNH4ENADAX
MDN4083LEA0722NMNH4ENADAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH4ENADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNGNNNHMCX
MDN4083LEA0422NMNGNNNHMCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNGNNNHMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEF363200LSGES2E5
SEF363200LSGES2E5
Schneider Electric - Insulated Case
SEF363200LSGES2E5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNKNEMNDPX
MDN4083LEA0122NMNKNEMNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNKNEMNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SEHF361400LSES3B8
SEHF361400LSES3B8
Square D - Insulated Case
SEHF361400LSES3B8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MJF36500UC
MJF36500UC
Schneider Electric - Molded Case
MJF36500UC, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 500A, 600V, 65kA@480V, UL listed, current limiting, Bolt-On, complete with 220/240Vac UVR, basic non-interchangeable ET 1.0 trip, LI - Long-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
PJM36100CU44AAA
PJM36100CU44AAA
Square D - Molded Case
PJM36100CU44AAA, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B auxiliary switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
E3V-A32-3P-1000A-BO-EO-LSI
E3V-A32-3P-1000A-BO-EO-LSI
ABB - Insulated Case
E3V-A32-3P-1000A-BO-EO-LSI, ABB, EMax, type , 3P, 3PH, 3200A frame, 1000A rating plug, 600V, 125kA@480V, fixed mount/Bolt-On, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
LA-4000A-MO-DO-LI
LA-4000A-MO-DO-LI
Siemens-Allis - Air
LA-4000A-MO-DO-LI, Siemens-Allis, LA Series, type , 4000A frame size, manually operated/Draw-Out, 3P, 3PH, 4000A current sensor rating, 600V, 85kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNF4ECNNWX
MDN4083LEA0622NMNF4ECNNWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF4ECNNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & 4A/4B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNKNENADPX
MDN4083LEA0722NMNKNENADPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNKNENADPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PDG32N0600D5DK
PDG32N0600D5DK
Cutler Hammer - Molded Case
PDG32N0600D5DK, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 600A, 85kA@480V, Bolt-On, line side lug terminals, complete with PXR20D ARMS trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU, CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0622NMNENENHMWX
MDN4083LEA0622NMNENENHMWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNENENHMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNA4YNHMWX
MDN4083LEA0822NMNA4YNHMWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA4YNHMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
PJP36100CU64AE1BC
PJP36100CU64AE1BC
Square D - Molded Case
PJP36100CU64AE1BC, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B alarm switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price