


- Home /
breaker
911,476 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0522NMNC2NNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC2NNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

SEHF36350LIES2A8
Schneider Electric - Insulated Case
SEHF36350LIES2A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

PGD36040U33AAA
Schneider Electric - Molded Case
PGD36040U33AAA, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with 1A/1B auxiliary switch, micrologic interchangeable standard 5.0 trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price

SSB3G668M
General Electric - Insulated Case
SSB3G668M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MPA41F1204120
General Electric - Insulated Case
MPA41F1204120, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 220/250V dc/ac motor operator, 24/30V dc closing coil and 48V dc shunt trip, 4P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price

MDN4083LEA0522NMNR2ENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR2ENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

SEHD363200LSIGES8
Schneider Electric - Insulated Case
SEHD363200LSIGES8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SHB4G6C2U
General Electric - Insulated Case
SHB4G6C2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SED36250LSIES3B4
Square D - Insulated Case
SED36250LSIES3B4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 250A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0722NMNANNNRDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNANNNRDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SED36600LIGET4
Square D - Insulated Case
SED36600LIGET4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0122HPR2NYNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122HPR2NYNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 48Vdc shunt trip (ST), 208-250Vac second shunt trip (STA), mechanical trip indicator & OTS switch, electrically operated with factory installed 220-240Vac motor operator & 208-250Vac spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price

MDN4083LEA0322NMNF2NNAMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNF2NNAMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0322NMNN2EHNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN2EHNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

MDN4083LEA0822NMNJNYNACWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNYNACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0522NMNXNYNKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNXNYNKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price

SHD1G3Z2F
General Electric - Insulated Case
SHD1G3Z2F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & ZSI features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MDN4083LEA0322NMNE2YNRDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNE2YNRDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

FCL340251433
Square D - Molded Case
FCL340251433, Square D, FCL Series, type , 3P, 3PH, 25A, 480V, 65kA@480V, extra high interrupting capacity, Feed-Thru, complete with 48Vdc shunt trip and 2A/2B aux switch, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers; these breakers are now obsolete, however we do still stock them
From Get Price

MDN4083LEA0222NMNX2NNCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX2NNCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price

DSL206-50A-MO-DO-LI
Cutler Hammer - Air
DSL206-50A-MO-DO-LI, Cutler Hammer, DSLII Series, type , 800A frame size, manually operated/Draw-Out, with current limiters, 3P, 3PH, 50A, 600V, 200kA@600V, available with solid state trip unit, Solid State electronic, air circuit breakers
From Get Price

MDN4083LEA0122NMNGNENNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNGNENNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassette, without shutters and unwired
From Get Price

MPA31F20V2030
General Electric - Insulated Case
MPA31F20V2030, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 48V dc motor operator and 110/130V dc/ac shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price

DSII-608-400A-MO-DO-LIG
Cutler Hammer - Air
DSII-608-400A-MO-DO-LIG, Cutler Hammer, DSII Series, type , 800A frame size, manually operated/Draw-Out, 3P, 3PH, 400A, 600V, 65kA@480V, available with Digitrip RMS solid state trip unit, Solid State electronic, low voltage power air circuit breakers
From Get Price