1. Home / 
  2. square d breaker

SORT BY
Limited Stock
DSII-616-1000A-MO-DO-LI
DSII-616-1000A-MO-DO-LI
Cutler Hammer - Air
DSII-616-1000A-MO-DO-LI, Cutler Hammer, DSII Series, type , 1600A frame size, manually operated/Draw-Out, 3P, 3PH, 1000A, 600V, 65kA@480V, available with Digitrip RMS solid state trip unit, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
SHB4G628R
SHB4G628R
General Electric - Insulated Case
SHB4G628R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communcation & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNG2ENCMSX
MDN4083LEA0222NMNG2ENCMSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNG2ENCMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNN4ENCDCX
MDN4083LEA0722NMNN4ENCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4ENCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MPA31F12W3010
MPA31F12W3010
General Electric - Insulated Case
MPA31F12W3010, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 110/130V dc/ac motor operator and 24/30V dc shunt trip, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNJ4ENLNPX
MDN4083LEA0322NMNJ4ENLNPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJ4ENLNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
EELCL520300SB2
EELCL520300SB2
Cutler Hammer - Mounting Hardware
EELCL520300SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 300A, BCL or ABR phase connection, 240V max, Copper, Single Branch mounting style, suitable for use with LCL circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNENYNKMPX
MDN4083LEA0722NMNENYNKMPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNENYNKMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNG2ENADAX
MDN4083LEA0322NMNG2ENADAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNG2ENADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNG2NNACWX
MDN4083LEA0422NMNG2NNACWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG2NNACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MPA31F12W0440
MPA31F12W0440
General Electric - Insulated Case
MPA31F12W0440, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac closing coil and 220/250V dc/ac shunt trip, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SHD2G4N6H
SHD2G4N6H
General Electric - Insulated Case
SHD2G4N6H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, modbus communication & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SPD277Y20SE01
SPD277Y20SE01
General Electric - Part And Accessory
SPD277Y20SE01, General Electric, EntellEon, type , Surge Protection device kit, 277Y, 200kA max single impulse surge current, SE disconnect device, SPD Type 1, suitable for use with EntellEon panelboards and can be mounted on the offset side of a 40 or 45 wide enclosure and interior frame
From Get Price
Limited Stock
SSD2G5A1Q
SSD2G5A1Q
General Electric - Insulated Case
SSD2G5A1Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering & RELT features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNF4NNLCSX
MDN4083LEA0322NMNF4NNLCSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNF4NNLCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHF2G4Y8K
SHF2G4Y8K
General Electric - Insulated Case
SHF2G4Y8K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication, relays & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PDG32M0400P3MJ
PDG32M0400P3MJ
Cutler Hammer - Molded Case
PDG32M0400P3MJ, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 400A, 65kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR25 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
MDN4083LEA0222NMNANNNLNCX
MDN4083LEA0222NMNANNNLNCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNANNNLNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNCNENKNCX
MDN4083LEA0522NMNCNENKNCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNCNENKNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHF1G3J3L
SHF1G3J3L
General Electric - Insulated Case
SHF1G3J3L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication and relays features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
WLL1D308AA
WLL1D308AA
Siemens - Insulated Case
WLL1D308AA, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 800A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU725 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SHD6G9X81
SHD6G9X81
General Electric - Insulated Case
SHD6G9X81, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
JGX410032GVH09
JGX410032GVH09
Cutler Hammer - Molded Case
JGX410032GVH09, Cutler Hammer, Series G, type , 4P, 3PH, 100A, 600V, 200kA@480V, current limiting, for Naval applications 50°C, not UL listed, Feed-Thru, complete breaker with 310+ electronic, non-interchangeable trip unit and line & load side lug terminals, Solid State, molded case circuit breakers
From Get Price
Limited Stock
SHF2G5W4T
SHF2G5W4T
General Electric - Insulated Case
SHF2G5W4T, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication, relays & ZSI features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price