1. Home / 
  2. square d breaker

SORT BY
Limited Stock
431871
431871
General Electric - Trip Units And Programmers
431871, General Electric, Record Plus, Selective electronic interchangeable trip (SMR1) with switchable rating plug, LS - Long-Time and Short-Time trip functions, rated for 125A, 690V, 3P, suitable for 4 pole, 3.5 trip FE160 frame- FEL molded case circuit breaker frame types, Solid State trip units & circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNANYNHMAX
MDN4083LEA0622NMNANYNHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNANYNHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNG2ENAMWX
MDN4083LEA0422NMNG2ENAMWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG2ENAMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
JGH4250NNH08
JGH4250NNH08
Cutler Hammer - Molded Case
JGH4250NNH08, FRAME ONLY, Cutler Hammer, Series G, Type , without trip unit, 4P, 3PH, 250A, 600V, 65kA@480V, high interrupting capacity, UL listed for Marine applications 40°C, Bolt-On, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
Q145H00S01
Q145H00S01
Siemens - Molded Case
Q145H00S01 Siemens Q Series, type , 1P, 1PH, 45A, 120V, with factory installed 120V shunt trip, 22kA@120V, high interrupting capacity, Plug-In, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SHD3G6R8M
SHD3G6R8M
General Electric - Insulated Case
SHD3G6R8M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & ZSI features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNNNNNNCWX
MDN4083LEA0722NMNNNNNNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNNNNNNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNC4NNHMAX
MDN4083LEA0722NMNC4NNHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC4NNHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNKNNMNCAX
MDN4083LEA0222NMNKNNMNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNKNNMNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
140MT-C3E-C10-MT
140MT-C3E-C10-MT
Allen-Bradley - Molded Case
From Get Price
Limited Stock
2610D40G20A
2610D40G20A
Westinghouse - Trip Units And Programmers
2610D40G20A, Westinghouse, Pow-R trip, aftermarket direct replacement retrofit Pow-R Trip 7 trip units and programmers, programmable to any amperage requirement, 400 - 5000A, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, suitable for use with Systems Pow-R/SPB insulated case circuit breakers
From Get Price
Limited Stock
TP84SSE7
TP84SSE7
General Electric - Insulated Case
TP84SSE7, General Electric, Power Break I, type , 3P, 3PH, 600V, 400A current sensor rating, 800A frame rating, 65kA@480V, 100% equipment rated, stationary, UL listed, standard interrupting capacity, Bolt-On, includes 72V electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNK4NNRCCX
MDN4083LEA0422NMNK4NNRCCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNK4NNRCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHF2G419H
SHF2G419H
General Electric - Insulated Case
SHF2G419H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNK4ENACPX
MDN4083LEA0622NMNK4ENACPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNK4ENACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNK4ENANCX
MDN4083LEA0322NMNK4ENANCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK4ENANCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
E4L-A32-3P-2000A-DO-EO-LSI
E4L-A32-3P-2000A-DO-EO-LSI
ABB - Insulated Case
E4L-A32-3P-2000A-DO-EO-LSI, ABB, EMax, type , 3P, 3PH, 3200A frame, 2000A rating plug, 600V, 125kA@480V, Draw-Out, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0422NMNCNNNHMAX
MDN4083LEA0422NMNCNNNHMAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNNNHMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNENNNNCSX
MDN4083LEA0822NMNENNNNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNENNNNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MPA31F20V0036
MPA31F20V0036
General Electric - Insulated Case
MPA31F20V0036, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 110/130V dc/ac shunt trip and 220/250V ac undervoltage trip with delay, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNK4NCNDSX
MDN4083LEA0822NMNK4NCNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK4NCNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
WLC2D316QB
WLC2D316QB
Siemens - Insulated Case
WLC2D316QB, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1600A, 600V, 150kA@480V, UL listed, very high interrupting capacity, Draw-Out, complete with solid state ETU727 programmer with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 1200A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MPA41F16W1300
MPA41F16W1300
General Electric - Insulated Case
MPA41F16W1300, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator and 110/130V dc/ac closing coil, 4P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNA2ENNDSX
MDN4083LEA0822NMNA2ENNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA2ENNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, with shutters, unwired
From Get Price