


- Home /
breaker
962,938 Results
Refine Results
In Stock
Subcategory
SORT BY

THP3030SSE5
General Electric - Insulated Case
THP3030SSE5, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 3000A current sensor rating, 3000A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 24Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP1610SSE5
General Electric - Insulated Case
THP1610SSE5, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 1000A current sensor rating, 1600A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 24Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2525SSE5
General Electric - Insulated Case
THP2525SSE5, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2500A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 24Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP82TTR
General Electric - Insulated Case
THP82TTR, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 200A current sensor rating, 800A frame rating, 150kA@480V, 100% rated, stationary, UL listed, standard interrupting capacity, suitable for reverse feed, Bolt-On, for use with MicroVersaTrip PM or Plus trip units, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2525SSE6
General Electric - Insulated Case
THP2525SSE6, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2500A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 48Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THCVVF3602E1
General Electric - Insulated Case
THCVVF3602E1, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 200A current sensor rating, 800A frame rating, 100kA@480V, 100% rated, UL listed, high interrupting capacity, suitable for reverse feed, Draw-Out, with 120V electrical motor operator, for use with MicroVersaTrip trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP3030SSE7
General Electric - Insulated Case
THP3030SSE7, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 3000A current sensor rating, 3000A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 72Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THPVF6620
General Electric - Insulated Case
THPVF6620, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2000A frame rating, 100kA@480V, 100% rated, stationary/fixed mount, high interrupting capacity, suitable for reverse feed, Bolt-On, for use with MicroVersaTrip Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THC84TTR
General Electric - Insulated Case
THC84TTR, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 400A current sensor rating, 800A frame rating, 150kA@480V, 100% rated, UL listed, high interrupting capacity, suitable for reverse feed, Draw-Out, for use with MicroVersaTrip PM or Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP4040SSE3
General Electric - Insulated Case
THP4040SSE3, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 4000A current sensor rating, 4000A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 125Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THC2510TTR
General Electric - Insulated Case
THC2510TTR, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 1000A current sensor rating, 2500A frame rating, 150kA@480V, 100% rated, UL listed, high interrupting capacity, suitable for reverse feed, Draw-Out, for use with MicroVersaTrip PM or Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP4040SSE1
General Electric - Insulated Case
THP4040SSE1, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 4000A current sensor rating, 4000A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 120Vac electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2520SSE3
General Electric - Insulated Case
THP2520SSE3, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 125Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2520SSE5
General Electric - Insulated Case
THP2520SSE5, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 24Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THPVV6620E3CK
General Electric - Insulated Case
THPVV6620E3CK, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2000A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, for use with MicroVersaTrip trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, electrically operated with 125VDC electrical motor operator, Solid State electrical, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2520SSE7
General Electric - Insulated Case
THP2520SSE7, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 72Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THC3030TTR
General Electric - Insulated Case
THC3030TTR, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 3000A current sensor rating, 3000A frame rating, 150kA@480V, 100% rated, UL listed, high interrupting capacity, suitable for reverse feed, Draw-Out, for use with MicroVersaTrip PM or Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2520SSE6
General Electric - Insulated Case
THP2520SSE6, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 48Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THPVVF3608R
General Electric - Insulated Case
THPVVF3608R, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 800A current sensor rating, 800A frame rating, 100kA@480V, 100% rated, stationary, UL listed, high interrupting capacity, suitable for reverse feed, Bolt-On, for use with MicroVersaTrip Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP84SSE1
General Electric - Insulated Case
THP84SSE1, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 400A current sensor rating, 800A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 120Vac electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2520TTR
General Electric - Insulated Case
THP2520TTR, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2000A current sensor rating, 2500A frame rating, 150kA@480V, 100% rated, stationary, UL listed, high interrupting capacity, suitable for reverse feed, Bolt-On, for use with MicroVersaTrip PM or Plus trip units, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THP2525SSE3
General Electric - Insulated Case
THP2525SSE3, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 2500A current sensor rating, 2500A frame rating, 150kA@480V, 100% equipment rated, stationary, UL listed, high interrupting capacity, Bolt-On, electrically operated with 125Vdc electrical motor operator, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THC1616TTR
General Electric - Insulated Case
THC1616TTR, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 1600A current sensor rating, 1600A frame rating, 150kA@480V, 100% rated, UL listed, high interrupting capacity, suitable for reverse feed, Draw-Out, for use with MicroVersaTrip PM or Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

THPVF5612
General Electric - Insulated Case
THPVF5612, General Electric, Power Break I, type , Hi-Break, 3P, 3PH, 600V, 1200A current sensor rating, 1600A frame rating, 100kA@480V, 100% rated, stationary/fixed mount, high interrupting capacity, suitable for reverse feed, Bolt-On, for use with MicroVersaTrip Plus trip units only, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price