1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MPA31F10N2420
MPA31F10N2420
General Electric - Insulated Case
MPA31F10N2420, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 48V dc motor operator, 220/250V dc/ac closing coil, 48V dc shunt trip, 3P, 3PH, 1000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNCNNCNMPX
MDN4083LEA0422NMNCNNCNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNNCNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHB1G261C
SHB1G261C
General Electric - Insulated Case
SHB1G261C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF2G5N7Q
SSF2G5N7Q
General Electric - Insulated Case
SSF2G5N7Q, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, modbus communication & ZSI features and 1100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
PEDB4ATGR0225
PEDB4ATGR0225
General Electric - Molded Case
PEDB4ATGR0225, General Electric, GuardEon, type , 3PH, 4P, 600V, 225A, 18kA@480V, front connection/Feed-Thru, toggle mechanism, complete with GTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MDN4083LEA0622NMNJ4YCNDSX
MDN4083LEA0622NMNJ4YCNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNJ4YCNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SKTT3410L5N2
SKTT3410L5N2
General Electric - Molded Case
SKTT3410L5N2, General Electric, Spectra Series, type , 3P, 3PH, 1000A, 480V, 65kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm + ZSI trip functions with extended instantaneous, basic metering + modbus features, Solid State with RELT and neutral protection, molded case circuit breakers
From Get Price
Limited Stock
WLH2F308LA
WLH2F308LA
Siemens - Insulated Case
WLH2F308LA, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 800A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU725 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 630A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MPA41F25W1350
MPA41F25W1350
General Electric - Insulated Case
MPA41F25W1350, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil and 380/400V ac shunt trip, 4P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNF4YCNMSX
MDN4083LEA0422NMNF4YCNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4YCNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SHF2G521P
SHF2G521P
General Electric - Insulated Case
SHF2G521P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNX2YNNDSX
MDN4083LEA0322NMNX2YNNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNX2YNNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
E3S-A25-3P-800A-DO-MO-LSI
E3S-A25-3P-800A-DO-MO-LSI
ABB - Insulated Case
E3S-A25-3P-800A-DO-MO-LSI, ABB, EMax, type , 3P, 3PH, 2500A frame, 800A rating plug, 600V, 65kA@480V, Draw-Out, manually operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SSB6G9J32
SSB6G9J32
General Electric - Insulated Case
SSB6G9J32, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSF2G4W8H
SSF2G4W8H
General Electric - Insulated Case
SSF2G4W8H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNE2NNADAX
MDN4083LEA0522NMNE2NNADAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE2NNADAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNX4ENCNCX
MDN4083LEA0722NMNX4ENCNCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNX4ENCNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNR4ENYDPX
MDN4083LEA0722NMNR4ENYDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR4ENYDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
E6V-A40-3P-3200A-BO-MO-LI
E6V-A40-3P-3200A-BO-MO-LI
ABB - Insulated Case
E6V-A40-3P-3200A-BO-MO-LI, ABB, EMax, type , 3P, 3PH, 4000A frame, 3200A rating plug, 600V, 125kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
THJ9V2603SGA3
THJ9V2603SGA3
General Electric - Molded Case
THJ9V2603SGA3 General Electric MicroVersaTrip, type , J600 frame type, 3P, 3PH, 300A, 600V, 35kA@480V, high interrupting capacity, Bolt-On, complete with 9-function MVT, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and trip indication targets, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNGNENLMSX
MDN4083LEA0822NMNGNENLMSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNGNENLMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & Castell key interock, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNX2ENYCPX
MDN4083LEA0622NMNX2ENYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX2ENYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNGNENYMAX
MDN4083LEA0522NMNGNENYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNGNENYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNNNNNYCWX
MDN4083LEA0822NMNNNNNYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNNNNNYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price