Limited Stock
MDN4083LEA0822NMNC4YNLCWX
MDN4083LEA0822NMNC4YNLCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4YNLCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
B204LSIGDMR
B204LSIGDMR
General Electric - Trip Units And Programmers
B204LSIGDMR, General Electric, MicroVersaTrip PM, type , replacement trip units and programmers, 400A current sensor rating, Solid State electronic, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, ground fault defeatable, trip functions, metering & communications, suitable for use with Power Break II SSD,SHD,SSF,SHF frame insulated case circuit breakers
From Get Price
Limited Stock
SSB1G3Q4L
SSB1G3Q4L
General Electric - Insulated Case
SSB1G3Q4L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNH2YHNDSX
MDN4083LEA0722NMNH2YHNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNH2YHNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
DS206-600A-EO-DO-LSG
DS206-600A-EO-DO-LSG
Cutler Hammer - Air
DS206-600A-EO-DO-LSG, Cutler Hammer, DS Series, type , 800A frame size, 300-600A trip range, electrically operated/Draw-Out, 3P, 3PH, 600A, 600V, 30kA@480V, available with solid state trip unit, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
MPA32F32V0052
MPA32F32V0052
General Electric - Insulated Case
MPA32F32V0052, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50L trip unit, 380/400V ac shunt trip and 110/130V ac undervoltage trip, 3P, 3PH, 3200A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
TJS2AB1UV6
TJS2AB1UV6
General Electric - Under Voltage Release
TJS2AB1UV6, General Electric, TJS Series, type , under voltage release, UVR with 1 auxiliary switch rated for 250V, 600V, suitable for use with TJS,THJS,THJSS frame molded case circuit breakers
From Get Price
Limited Stock
NEG1C020
NEG1C020
Siemens - Molded Case
NEG1C020, Siemens, VL Series, type , 1P, 1PH, 20A, 600V, 35kA@480V, standard interrupting capacity, suitable for reverse feed applications, Bolt-On, 50ºC calibrated, complete with LI - Long-Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
LA-600A-EO-DO-LIG
LA-600A-EO-DO-LIG
Siemens-Allis - Air
LA-600A-EO-DO-LIG, Siemens-Allis, LA Series, type , 600A frame size, electrically operated/Draw-Out, 3P, 3PH, 80-600A current sensor ratings available, 600V, 30kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LIG - Long-Time, Instantaneous and Ground Fault trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNE4YNCCAX
MDN4083LEA0222NMNE4YNCCAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4YNCCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
WLH2F308CC
WLH2F308CC
Siemens - Insulated Case
WLH2F308CC, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 800A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 250A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SSD3G6B8M
SSD3G6B8M
General Electric - Insulated Case
SSD3G6B8M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & modbus communication features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNG2NNANAX
MDN4083LEA0822NMNG2NNANAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG2NNANAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & operations counter, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F16W3000
MPA31F16W3000
General Electric - Insulated Case
MPA31F16W3000, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit and 110/130V dc/ac motor operator, 3P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SHB1G1M8B
SHB1G1M8B
General Electric - Insulated Case
SHB1G1M8B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT, modbus communication & ZSI features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NPRKNNNNNAX
MDN4083LEA0122NPRKNNNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NPRKNNNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, electrically operated with 220-240Vac motor operator and 208-250Vac/dc spring release device (SRD), factory installed 600Vac UVR & mechanical trip indicator, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNH2YNYDWX
MDN4083LEA0622NMNH2YNYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNH2YNYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNH4YNHCAX
MDN4083LEA0322NMNH4YNHCAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH4YNHCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA41F20N0002
MPA41F20N0002
General Electric - Air
MPA41F20N0002, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit and 110/130V dc/ac undervoltage trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNG2ENYMAX
MDN4083LEA0522NMNG2ENYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG2ENYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHB5G8X3W
SHB5G8X3W
General Electric - Insulated Case
SHB5G8X3W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNR4ENAMPX
MDN4083LEA0622NMNR4ENAMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR4ENAMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHB4G6E3R
SHB4G6E3R
General Electric - Insulated Case
SHB4G6E3R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, RELT & modbus communication features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0122NMNK2YHNNCX
MDN4083LEA0122NMNK2YHNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNK2YHNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price