TPSS7625BSG3
TPSS7625BSG3
General Electric - Insulated Case
TPSS7625BSG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2500A, inverted construction, with ground-fault protection, 3-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPMM7606
TPMM7606
General Electric - Insulated Case
TPMM7606, General Electric, Power Break I, type , 3P, 3PH, 600V, 600A current sensor rating, 2500A frame rating, 65kA@480V, UL listed, 100% equipment rated, stationary, standard interrupting capacity, Bolt-On, for use with MagneTrip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
TPSS7625E5
TPSS7625E5
General Electric - Insulated Case
TPSS7625E5, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2500A, electrically operated with 24Vdc electrical motor operator, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS9640SG3
THSS9640SG3
General Electric - Insulated Case
THSS9640SG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 4000A, 150kA@480V, high interrupting capacity, with ground-fault protection, 3-phase, 3-wire, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS8630FCG3
TPSS8630FCG3
General Electric - Insulated Case
TPSS8630FCG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, Front Connected, with ground fault protection, 3-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS8630BSG
TPSS8630BSG
General Electric - Insulated Case
TPSS8630BSG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, inverted construction, with ground-fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252LD23
THS252LD23
General Electric - Insulated Case
THS252LD23, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2300A, 150kA@480V, standard interrupting capacity, Feed-Thru, manually operated, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS8630BG3
THSS8630BG3
General Electric - Insulated Case
THSS8630BG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, inverted construction, with ground fault protection, 3-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS20307E4
THS20307E4
General Electric - Insulated Case
THS20307E4, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 700A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 250Vdc electrical motor operator, includes bus connectors and standard dual magnetic trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203LD16
THS203LD16
General Electric - Insulated Case
THS203LD16, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1600A, 150kA@480V, standard interrupting capacity, Feed-Thru, manually operated, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4800-12,800A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TCMM7608
TCMM7608
General Electric - Insulated Case
TCMM7608, General Electric, Power Break I, type , 3P, 3PH, 600V, 800A current sensor rating, 2500A frame size, 65kA@480V, 100% equipment rated, UL listed, standard interrupting capacity, Draw-Out, for use with TPDT08, interchangeable MagneTrip trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS7625E4
TPSS7625E4
General Electric - Insulated Case
TPSS7625E4, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2500A, electrically operated with 250Vdc electrical motor operator, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS30325E4
THS30325E4
General Electric - Insulated Case
THS30325E4, General Electric, Power Break I, Dual Magnetic type , 3000A frame, 3P, 3PH, 600V, 2500A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 250Vdc electrical motor operator, includes bus connectors and standard dual magnetic trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS303L20
THS303L20
General Electric - Insulated Case
THS303L20, General Electric, Power Break I, Dual Magnetic type , 3000A frame, 3P, 3PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, manually operated, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS8630FCSG3
THSS8630FCSG3
General Electric - Insulated Case
THSS8630FCSG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, front connected with ground fault protection, 3-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS403LD30
THS403LD30
General Electric - Insulated Case
THS403LD30, General Electric, Power Break I, Dual Magnetic type , 4000A frame, 3P, 3PH, 600V, 3000A, 150kA@480V, standard interrupting capacity, Feed-Thru, manually operated, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 9000-16,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS6610BSG
TPSS6610BSG
General Electric - Insulated Case
TPSS6610BSG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 1000A, inverted construction, with ground-fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS25220E6
THS25220E6
General Electric - Insulated Case
THS25220E6, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and standard dual magnetic trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS20308E3
THS20308E3
General Electric - Insulated Case
THS20308E3, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 125Vdc electrical motor operator, includes bus connectors and standard dual magnetic trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS8630E3
THSS8630E3
General Electric - Insulated Case
THSS8630E3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, electrically operated with 125Vdc electrical motor operator, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS20312E2
THS20312E2
General Electric - Insulated Case
THS20312E2, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1200A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and standard dual magnetic trip unit, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TCMM5606
TCMM5606
General Electric - Insulated Case
TCMM5606, General Electric, Power Break I, type , 3P, 3PH, 600V, 600A current sensor rating, 1600A frame size, 65kA@480V, 100% equipment rated, UL listed, standard interrupting capacity, Draw-Out, for use with non-interchangeable MagneTrip trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
TCMM5616
TCMM5616
General Electric - Insulated Case
TCMM5616, General Electric, Power Break I, type , 3P, 3PH, 600V, 1600A current sensor rating, 1600A frame size, 65kA@480V, 100% equipment rated, UL listed, standard interrupting capacity, Draw-Out, for use with non-interchangeable MagneTrip trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
THS203L18
THS203L18
General Electric - Insulated Case
THS203L18, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1800A, 150kA@480V, standard interrupting capacity, Feed-Thru, manually operated, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 5400-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price