1. Home / 
  2. breaker

SORT BY
Limited Stock
THS203LD07E5
THS203LD07E5
General Electric - Insulated Case
THS203LD07E5, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 700A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 24Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 2100-7000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS7625FCG
TPSS7625FCG
General Electric - Insulated Case
TPSS7625FCG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2500A, Front Connected, with ground fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252L23E4
THS252L23E4
General Electric - Insulated Case
THS252L23E4, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2300A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 250Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202LD20E5
THS202LD20E5
General Electric - Insulated Case
THS202LD20E5, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 24Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS403L35E6
THS403L35E6
General Electric - Insulated Case
THS403L35E6, General Electric, Power Break I, Dual Magnetic type , 4000A frame, 3P, 3PH, 600V, 3500A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 9000-16,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252L25E6
THS252L25E6
General Electric - Insulated Case
THS252L25E6, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2500A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS253L18E2
THS253L18E2
General Electric - Insulated Case
THS253L18E2, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 3P, 3PH, 600V, 1800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 5400-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202LD06E5
THS202LD06E5
General Electric - Insulated Case
THS202LD06E5, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 24Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 1800-6000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS7625BG
THSS7625BG
General Electric - Insulated Case
THSS7625BG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2500A, inverted construction, with ground fault protection, 1-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS6610BG
TPSS6610BG
General Electric - Insulated Case
TPSS6610BG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 1000A, inverted construction, with ground-fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS8630BDG
TPSS8630BDG
General Electric - Insulated Case
TPSS8630BDG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, inverted construction, with ground-fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203LD12E3
THS203LD12E3
General Electric - Insulated Case
THS203LD12E3, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1200A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 125Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 3600-10,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203L10E1
THS203L10E1
General Electric - Insulated Case
THS203L10E1, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 3000-10,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS403L35E3
THS403L35E3
General Electric - Insulated Case
THS403L35E3, General Electric, Power Break I, Dual Magnetic type , 4000A frame, 3P, 3PH, 600V, 3500A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 125Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 9000-16,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS6606BDG
THSS6606BDG
General Electric - Insulated Case
THSS6606BDG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 600A, inverted construction, with ground fault protection, 1-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202L07E2
THS202L07E2
General Electric - Insulated Case
THS202L07E2, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 700A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 2100-7000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252L16E1
THS252L16E1
General Electric - Insulated Case
THS252L16E1, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 1600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4800-12,800A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202L06E3
THS202L06E3
General Electric - Insulated Case
THS202L06E3, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 125Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 1800-6000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202L12E2
THS202L12E2
General Electric - Insulated Case
THS202L12E2, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 1200A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 3600-10,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS253L16E6
THS253L16E6
General Electric - Insulated Case
THS253L16E6, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 3P, 3PH, 600V, 1600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4800-12,800A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202LD18E4
THS202LD18E4
General Electric - Insulated Case
THS202LD18E4, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 1800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 250Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 5400-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252LD20E2
THS252LD20E2
General Electric - Insulated Case
THS252LD20E2, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203L14E2
THS203L14E2
General Electric - Insulated Case
THS203L14E2, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1400A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4200-11,200A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203LD14E2
THS203LD14E2
General Electric - Insulated Case
THS203LD14E2, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1400A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4200-11,200A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price