1. Home / 
  2. breaker

SORT BY
Limited Stock
THS252LD20E6
THS252LD20E6
General Electric - Insulated Case
THS252LD20E6, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS6606FCG3
THSS6606FCG3
General Electric - Insulated Case
THSS6606FCG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 600A, front connected with ground fault protection, 3-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252L16E2
THS252L16E2
General Electric - Insulated Case
THS252L16E2, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 1600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 240Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 4800-12,800A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS9640BDG3
THSS9640BDG3
General Electric - Insulated Case
THSS9640BDG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 4000A, inverted construction, with ground fault protection, 3-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS6620BDG3
THSS6620BDG3
General Electric - Insulated Case
THSS6620BDG3, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2000A, inverted construction, with ground fault protection, 3-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203LD08E1
THS203LD08E1
General Electric - Insulated Case
THS203LD08E1, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 2400-8000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS253LD20E5
THS253LD20E5
General Electric - Insulated Case
THS253LD20E5, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 3P, 3PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 24Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203L10E6
THS203L10E6
General Electric - Insulated Case
THS203L10E6, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 3000-10,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203L08E3
THS203L08E3
General Electric - Insulated Case
THS203L08E3, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 125Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 2400-8000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS8630FCG
TPSS8630FCG
General Electric - Insulated Case
TPSS8630FCG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, Front Connected, with ground fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203LD18E1
THS203LD18E1
General Electric - Insulated Case
THS203LD18E1, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 1600A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 5400-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
TPSS9640BG
TPSS9640BG
General Electric - Insulated Case
TPSS9640BG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 4000A, inverted construction, with ground-fault protection, 1-phase, 3-wire, 100kA@480V, standard interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203L20E6
THS203L20E6
General Electric - Insulated Case
THS203L20E6, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252LD18E1
THS252LD18E1
General Electric - Insulated Case
THS252LD18E1, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 1800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 5400-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS303L25E5
THS303L25E5
General Electric - Insulated Case
THS303L25E5, General Electric, Power Break I, Dual Magnetic type , 3000A frame, 3P, 3PH, 600V, 2500A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 24Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 8000-15,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252LD20E1
THS252LD20E1
General Electric - Insulated Case
THS252LD20E1, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS252L23E1
THS252L23E1
General Electric - Insulated Case
THS252L23E1, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 2P, 1PH, 600V, 2300A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202LD18E1
THS202LD18E1
General Electric - Insulated Case
THS202LD18E1, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 1800A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 5400-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS6606BG
THSS6606BG
General Electric - Insulated Case
THSS6606BG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 600A, inverted construction, with ground fault protection, 1-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS202LD10E1
THS202LD10E1
General Electric - Insulated Case
THS202LD10E1, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 2P, 1PH, 600V, 1000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 3000-10,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS403L30E4
THS403L30E4
General Electric - Insulated Case
THS403L30E4, General Electric, Power Break I, Dual Magnetic type , 4000A frame, 3P, 3PH, 600V, 3000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 250Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 9000-16,000A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS203LD20E6
THS203LD20E6
General Electric - Insulated Case
THS203LD20E6, General Electric, Power Break I, Dual Magnetic type , 2000A frame, 3P, 3PH, 600V, 2000A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 48Vdc electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THS253L25E1
THS253L25E1
General Electric - Insulated Case
THS253L25E1, General Electric, Power Break I, Dual Magnetic type , 2500A frame, 3P, 3PH, 600V, 2500A, 150kA@480V, standard interrupting capacity, Feed-Thru, electrically operated with 120Vac electrical motor operator, includes bus connectors and dual magnetic trip unit with adjustable ampere setting, 6000-13,600A, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
THSS8630BG
THSS8630BG
General Electric - Insulated Case
THSS8630BG, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 3000A, inverted construction, with ground fault protection, 1-phase, 3-wire, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LIG - Long-Time, Instantaneous and Ground Fault trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price