1. Home / 
  2. square d breaker

SORT BY
Limited Stock
FG3045S12
FG3045S12
Eaton - Molded Case
FG3045S12, Cutler Hammer, Westinghouse, Eaton, Series C, type , 3P, 3PH, 45A, 600V, 14kA@480V, standard interrupting capacity, Feed-Thru, suitable for reverse feed applications, fixed magnetic pickup range, complete with left-pole mounted 208-380Vac or 110-127Vdc, 50/60Hz terminal block left side mount shunt trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, engine generator molded case circuit breakers
From Get Price
Limited Stock
SKLL3612L5M6
SKLL3612L5M6
General Electric - Molded Case
SKLL3612L5M6 General Electric Spectra Series, type , 3P, 3PH, 1200A, 600V, 65kA@480V, extra high interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIA, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm and ZSI, zone selective interlocking & neutral protection trip functions and basic metering, modbus & waveform capture communication features, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
WLS2F320MW
WLS2F320MW
Siemens - Insulated Case
WLS2F320MW, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 2000A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU755 programmer + WLGFA76 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 700A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNFNYNNCCX
MDN4083LEA0222NMNFNYNNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNFNYNNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PDF54N0800P2WM
PDF54N0800P2WM
Eaton - Molded Case
PDF54N0800P2WM, Eaton, Cutler Hammer, Power Defense, type , 3PH, 4P, 600V, 800A, 85kA@480V, Bolt-On, no terminals with metric tapped conductors, complete with PXR25 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with relays, modbus & ZSI option, Solid State electronic, molded case circuit breakers; globally rated with 100% UL rating
From Get Price
Limited Stock
SSB1G357K
SSB1G357K
General Electric - Insulated Case
SSB1G357K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
TC2520SS
TC2520SS
General Electric - Insulated Case
TC2520SS, General Electric, Power Break I, type , 3P, 3PH, 600V, 2000A current sensor rating, 2500A frame rating, 100kA@480V, 100% equipment rated, UL listed, standard interrupting capacity, suitable for reverse feed, Draw-Out, for use with MicroVersaTrip RMS-9 programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNF4YHNCCX
MDN4083LEA0422NMNF4YHNCCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4YHNCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHD1G3L7K
SHD1G3L7K
General Electric - Insulated Case
SHD1G3L7K, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNXNNMNDWX
MDN4083LEA0522NMNXNNMNDWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNXNNMNDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNH2ENNCSX
MDN4083LEA0122NMNH2ENNCSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNH2ENNCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNH2ENNCAX
MDN4083LEA0422NMNH2ENNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2ENNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNE4NNNDCX
MDN4083LEA0222NMNE4NNNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4NNNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNC4ENYCWX
MDN4083LEA0222NMNC4ENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNC4ENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNX4YNCCWX
MDN4083LEA0222NMNX4YNCCWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX4YNCCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNK4YNCMPX
MDN4083LEA0222NMNK4YNCMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNK4YNCMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNJ4ENYMAX
MDN4083LEA0722NMNJ4ENYMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ4ENYMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MPA31F25W0100
MPA31F25W0100
General Electric - Insulated Case
MPA31F25W0100, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit and 24/30V dc closing coil, 3P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNF4YNACPX
MDN4083LEA0422NMNF4YNACPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNF4YNACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNC4ENCCSX
MDN4083LEA0622NMNC4ENCCSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4ENCCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNN4YNACCX
MDN4083LEA0522NMNN4YNACCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN4YNACCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNCNENKDSX
MDN4083LEA0622NMNCNENKDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNCNENKDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
GB500L8XXXRXXXX
GB500L8XXXRXXXX
General Electric - Trip Units And Programmers
GB500L8XXXRXXXX, General Electric, EntelliGuard, replacement trip units and programmers for 3000A Power Break II breakers; Solid State electronic, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions; universal sensor rating
From Get Price
Limited Stock
FNT309632TSK5ANCT
FNT309632TSK5ANCT
General Electric - Part And Accessory
FNT309632TSK5ANCT, General Electric, EntellEon, type , panelboard front, Type 1 non-vented, top, 30 enclosure width
From Get Price