1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0222NMNA4ENNNPX
MDN4083LEA0222NMNA4ENNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNA4ENNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, & load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNE2NNHCPX
MDN4083LEA0722NMNE2NNHCPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNE2NNHCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNA4NNACWX
MDN4083LEA0322NMNA4NNACWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA4NNACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SEHF36300LSIES6A8
SEHF36300LSIES6A8
Schneider Electric - Insulated Case
SEHF36300LSIES6A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 300A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNN2NNHMCX
MDN4083LEA0622NMNN2NNHMCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNN2NNHMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSB1G2N4C
SSB1G2N4C
General Electric - Insulated Case
SSB1G2N4C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNX4NNHCCX
MDN4083LEA0222NMNX4NNHCCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNX4NNHCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEHD362500LSIGES3C8
SEHD362500LSIGES3C8
Square D - Insulated Case
SEHD362500LSIGES3C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD363000LSIGES5D8
SEHD363000LSIGES5D8
Schneider Electric - Insulated Case
SEHD363000LSIGES5D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
E3H-A16-4P-1000A-DO-EO-LSI
E3H-A16-4P-1000A-DO-EO-LSI
ABB - Insulated Case
E3H-A16-4P-1000A-DO-EO-LSI, ABB, EMax, type , 4P, 3PH, 1600A frame, 1000A rating plug, 600V, 85kA@480V, Draw-Out, electrically operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
THSS6620E4
THSS6620E4
General Electric - Insulated Case
THSS6620E4, General Electric, Power Break I, VersaTrip type , 3P, 3PH, 600V, 2000A, electrically operated with 250Vdc electrical motor operator, 150kA@480V, high interrupting capacity, Feed-Thru, for use with VersaTrip programmers, LI - Long-Time and Instantaneous trip functions, supplied with line & load terminal studs, Thermal Magnetic insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
SSB1G1F7B
SSB1G1F7B
General Electric - Insulated Case
SSB1G1F7B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNK2ENADSX
MDN4083LEA0722NMNK2ENADSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK2ENADSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
AKS-6-50H
AKS-6-50H
General Electric - Air
AKS-6-50H, General Electric, AK Series, type , 1600A frame, 3PH, 3P, 635VAC, 300-1600A sensor rating, 65kA@508V, Draw-Out, AKD, available either mechanically or electrically operated, with MicroVersaTrip Solid State programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage air circuit breakers
From Get Price
Limited Stock
E2K3400MGWS32
E2K3400MGWS32
Westinghouse - Molded Case
E2K3400MGWS32, Westinghouse, Cutler Hammer, Eaton, Series C, E2 mining service breakers, type , 3P, 3PH, 400A, 600V, 250Vdc, 25kA@600V, standard interrupting capacity, Bolt-On, complete with mag only trip, right-pole mounted 110-240Vac 50/60Hz or 110-125Vdc, terminal block right side mount shunt trip, I - Instantaneous protection only, magnetic range 750-1500A lugs not included, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
SEF36200ES6A4
SEF36200ES6A4
Square D - Insulated Case
SEF36200ES6A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
K1600S-MO-DO-LS
K1600S-MO-DO-LS
ABB - Air
K1600S-MO-DO-LS, ABB, K-Line, type , 1600A frame size, manually operated/Draw-Out, 3P, 3PH, 1600A, 600V, 50kA@480V, originally supplied with SS solid state trip device but can also be retrofitted with a modern Solid State electronic trip unit with LS - Long-Time and Short-Time trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNFNNNRDSX
MDN4083LEA0822NMNFNNNRDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNFNNNRDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
NPJL36040U63AE1YP
NPJL36040U63AE1YP
Schneider Electric - Molded Case
NPJL36040U63AE1YP, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 400A, 600V, 65kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with fixed handle padlocking device, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNG4YCKNPX
MDN4083LEA0422NMNG4YCKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNG4YCKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Kirk keylock, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
WLL2D316ED
WLL2D316ED
Siemens - Insulated Case
WLL2D316ED, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 1600A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLLCD48 LCD display, LSI - Long-Time, Short-Time and Instantaneous trip functions and 315A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SSD3G6K7P
SSD3G6K7P
General Electric - Insulated Case
SSD3G6K7P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNJNNNRDWX
MDN4083LEA0822NMNJNNNRDWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJNNNRDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSD1G2F3C
SSD1G2F3C
General Electric - Insulated Case
SSD1G2F3C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price