1. Home / 
  2. square d breaker

SORT BY
Limited Stock
MDN4083LEA0122NMNENENHNWX
MDN4083LEA0122NMNENENHNWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNENENHNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSF3G6E2M
SSF3G6E2M
General Electric - Insulated Case
SSF3G6E2M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNXNYMNMPX
MDN4083LEA0222NMNXNYMNMPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNXNYMNMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0122NMNC4ENKDWX
MDN4083LEA0122NMNC4ENKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC4ENKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
WLL2D325NW
WLL2D325NW
Siemens - Insulated Case
WLL2D325NW, Siemens, WL Series, type , frame size II, drawout, 3P, 3PH, 2500A, 600V, 100kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with solid state ETU755 programmer + WLGFA76 ground fault module, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 800A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SHF1G334N
SHF1G334N
General Electric - Insulated Case
SHF1G334N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNG2ENACWX
MDN4083LEA0722NMNG2ENACWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG2ENACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNG2EHKMSX
MDN4083LEA0522NMNG2EHKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG2EHKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & 2A/2B auxiliary switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MPA31F12W2100
MPA31F12W2100
General Electric - Insulated Case
MPA31F12W2100, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50H trip unit, 48V dc motor operator and 24/30V dc closing coil, 3P, 3PH, 1250A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SHB3G626W
SHB3G626W
General Electric - Insulated Case
SHB3G626W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNRNENYNAX
MDN4083LEA0822NMNRNENYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNRNENYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNNNECNDAX
MDN4083LEA0722NMNNNECNDAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNNNECNDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNG4NCKDWX
MDN4083LEA0722NMNG4NCKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNG4NCKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, latch check switch for external wiring, load side lug terminals, Kirk keylock, 4A/4B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
WLS2F316BG
WLS2F316BG
Siemens - Insulated Case
WLS2F316BG, Siemens, WL Series, type , frame size II, fixed mount, 3P, 3PH, 1600A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFM48 ground fault module, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and 225A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
E6V-A40-3P-3600A-BO-MO-LI
E6V-A40-3P-3600A-BO-MO-LI
ABB - Insulated Case
E6V-A40-3P-3600A-BO-MO-LI, ABB, EMax, type , 3P, 3PH, 4000A frame, 3600A rating plug, 600V, 125kA@480V, fixed/Bolt-On, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
HMCP400R5S09
HMCP400R5S09
Westinghouse - Molded Case
HMCP400R5S09, Westinghouse, Cutler Hammer, Eaton, Series C, type , K Frame, 3P, 3PH, 400A, 600V, 35kA@480V, Feed-Thru, complete with left-pole mounted 110-240Vac left side shunt trip, I - Instantaneous Protection Only and standard line & load side lug terminals, magnetic range 1750-3500A, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
PCALK415
PCALK415
General Electric - Lug Terminal Kit
PCALK415, General Electric, GuardEon, lug terminal kit, 4 pole, 2.08-13.3mm conductors, Al/Cu, suitable for use with 4P, 25-150A PE150 frame type
From Get Price
Limited Stock
MDN4083LEA0822NMNN4YNHDAX
MDN4083LEA0822NMNN4YNHDAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN4YNHDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHD1G194A
SHD1G194A
General Electric - Insulated Case
SHD1G194A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, modbus communication, relays & ZSI features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNR2ENKDPX
MDN4083LEA0822NMNR2ENKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNR2ENKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SB16TP01
SB16TP01
Siemens - Trip Units And Programmers
SB16TP01, Siemens, SB Series, type , Solid State digital electronic interchangeable programmer / trip unit device, complete with LSI - Long-Time, Short-Time and Instantaneous trip functions, rated for 1600A, standard model including real-time voltage and current waveform displays, overcurrent protection, metering and communications, suitable for use with SBA,SBH,SBS insulated case circuit breaker frame types, these trip unit devices are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SSF1G3Z8I
SSF1G3Z8I
General Electric - Insulated Case
SSF1G3Z8I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0322NMNHNYNANWX
MDN4083LEA0322NMNHNYNANWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNHNYNANWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SHB4G7Y2W
SHB4G7Y2W
General Electric - Insulated Case
SHB4G7Y2W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price