1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MDN4083LEA0522NMNH4YNHMCX
MDN4083LEA0522NMNH4YNHMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNH4YNHMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PKP46120U43AYP
PKP46120U43AYP
Square D - Molded Case
PKP46120U43AYP, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 1200A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with fixed handle padlocking device, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SSD1G1Q4A
SSD1G1Q4A
General Electric - Insulated Case
SSD1G1Q4A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHB6G987W
SHB6G987W
General Electric - Insulated Case
SHB6G987W, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication, relays & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E4H-A36-3P-3000A-DO-MO-LSI
E4H-A36-3P-3000A-DO-MO-LSI
ABB - Insulated Case
E4H-A36-3P-3000A-DO-MO-LSI, ABB, EMax, type , 3P, 3PH, 3600A frame, 3000A rating plug, 600V, 85kA@480V, Draw-Out, manually operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
E4V-A36-4P-3600A-DO-MO-LSI
E4V-A36-4P-3600A-DO-MO-LSI
ABB - Insulated Case
E4V-A36-4P-3600A-DO-MO-LSI, ABB, EMax, type , 4P, 3PH, 3600A frame, 3600A rating plug, 600V, 100kA@480V, Draw-Out, manually operated, Solid State electronic with LSI - Long-Time, Short-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0522NMNG4YNCNSX
MDN4083LEA0522NMNG4YNCNSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG4YNCNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
184L701UVG17
184L701UVG17
General Electric - Under Voltage Release
184L701UVG17, General Electric, AKR Series, replacement under voltage release UVR with time delay, 480Vac, 50Hz, suitable for use with AK-2-15,AK-2A-15,AK-25,AKU-25,AKR-30S,AKRU-30S low voltage air circuit breakers
From Get Price
Limited Stock
SSF4G6X4W
SSF4G6X4W
General Electric - Insulated Case
SSF4G6X4W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED36200LSIES4B4
SED36200LSIES4B4
Square D - Insulated Case
SED36200LSIES4B4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SED363200LSES5D8
SED363200LSES5D8
Square D - Insulated Case
SED363200LSES5D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHF1G317L
SHF1G317L
General Electric - Insulated Case
SHF1G317L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED361400LSIES2
SED361400LSIES2
Schneider Electric - Insulated Case
SED361400LSIES2, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1400A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHF1G3Z2J
SHF1G3Z2J
General Electric - Insulated Case
SHF1G3Z2J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & ZSI features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0722NMNFNENACPX
MDN4083LEA0722NMNFNENACPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNFNENACPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN6084LEA
MDN6084LEA
Cutler Hammer - Insulated Case
MDN6084LEA, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 4P with neutral, 3PH, NABC phase, 800A, 600V, 65kA@600V, 40°C, Bolt-On, complete with interchangeable Digitrip, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEHD361000LSIGES9D8
SEHD361000LSIGES9D8
Square D - Insulated Case
SEHD361000LSIGES9D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNN4ECNDSX
MDN4083LEA0822NMNN4ECNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN4ECNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHD36800LSGES2E8
SEHD36800LSGES2E8
Square D - Insulated Case
SEHD36800LSGES2E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0222NMNE4NNCNPX
MDN4083LEA0222NMNE4NNCNPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4NNCNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNJ2YNYDAX
MDN4083LEA0322NMNJ2YNYDAX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNJ2YNYDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEHD361200LSES1D8
SEHD361200LSES1D8
Square D - Insulated Case
SEHD361200LSES1D8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1200A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHF36250LIEV1
SEHF36250LIEV1
Square D - Insulated Case
SEHF36250LIEV1, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 250A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & undervoltage trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
TJ9V2601D
TJ9V2601D
General Electric - Molded Case
TJ9V2601D General Electric MicroVersaTrip, type , J600 frame type, 3P, 3PH, 150A, 600V, 30kA@480V, standard interrupting capacity, Bolt-On, complete with 9-function MVT, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price