- Home /
square d breaker
449,252 Results
Refine Results
In Stock
Subcategory
SORT BY

MP16H2-3P-1600A-EO-DO-LI
Merlin Gerin - Insulated Case
MP16H2-3P-1600A-EO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1600A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

KB2100T
Westinghouse - Trip Units And Programmers
KB2100T, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $290.66

449D701G03
Westinghouse - Metering
449D701G03 / <strong>3A73103G03</strong>, Westinghouse, Cutler Hammer, Eaton, Westinghouse, Cutler Hammer, Eaton, DS Series, Metering Current Transformer 200/5, RCT-1600, DSM-16, qty 3 required per breaker, suitable for use with DS-206, DSL-206, DS-206S, DS-206E, DS-416, DSL-416, DS-416H, DS-416S, DS-420, DSII-308, DSII-516, DSII-620 low voltage power air breakers
From Get Price

MP32H-3P-3200A-EO-DO-LSG
Merlin Gerin - Insulated Case
MP32H-3P-3200A-EO-DO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

ECN2428BAW
Cutler Hammer - Motor Starter
ECN2428BAW, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 15 HP @ 230V, 600V, complete with 240V coil, NEMA size 2, 70A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price

ECN2458BAK
Cutler Hammer - Motor Starter
ECN2458BAK, Cutler Hammer, Freedom Series, combination, non-reversing motor starter with HMCP and CPT (control power transformers), type , 3P, 3PH, 100 HP @ 230V, 600V, complete with 240V coil, NEMA size 5, 400A HMCP circuit breaker enclosed in NEMA Type 12 dust-tight industrial enclosure with external reset, suitable for use with Freedom Series motor control systems
From Get Price

CR306EXK004
General Electric - Motor Starter
CR306EXK004, General Electric, 300 Line, type , 3P, 3PH, 90A, 600V, 50 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 3, equipped with overload rely to provide 17.0-35.0A with 125 max fuse rating, 125 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

JT3100TS41
Cutler Hammer - Trip Units And Programmers
JT3100TS41, Cutler Hammer, Series C, type , trip units and programmers, interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for HJDDC,JD,HJD,JDC molded case circuit breaker frame types, left pole mounted 12-24Vac/dc shunt trip, 18-inch pigtail leads same side, Thermal Magnetic trip units & circuit breakers
From Get Price

CR306FXP003
General Electric - Motor Starter
CR306FXP003, General Electric, 300 Line, type , 3P, 3PH, 135A, 600V, 50 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination open type magnetic starter, NEMA size 4-5, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

HKA2175TA
Westinghouse - Trip Units And Programmers
HKA2175TA, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 175A, 50°C, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HKA32250TM
Cutler Hammer - Trip Units And Programmers
HKA32250TM, Cutler Hammer, MARK 75, type , interchangeable trip unit with I - Instantaneous only trip function, rated for 225A, magnetic trip range 1125-2250A, suitable for 225A- KA,HKA Magnetic Only front adjustable molded case circuit breaker frame types, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $1,907.11

THQL21W20
General Electric - Molded Case
THQL21W20, General Electric, Q-Line, type , 2P, 1PH, 120/240V, 20A, 10kA@240V, common trip, UL listed, high interrupting capacity, Plug-In, LI - Long-Time and Instantaneous trip functions, load side lug terminals, for use with PowerMark circuit breaker load centers, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price

MP63H-3P-6000A-MO-BO-LI
Merlin Gerin - Insulated Case
MP63H-3P-6000A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP20-3P-2000A-EO-DO-LSIG
Merlin Gerin - Insulated Case
MP20-3P-2000A-EO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

HKB2200TV
Westinghouse - Trip Units And Programmers
HKB2200TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 250A- KB,HKB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

MP32-3P-3000A-MO-DO-LSIG
Merlin Gerin - Insulated Case
MP32-3P-3000A-MO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3000A, 3200A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

PAF28000TM
Westinghouse - Trip Units And Programmers
PAF28000TM, Westinghouse, PAF Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, front connected, rated for 2000A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, magnetic trip range 3500-8000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HNB212000TMV
Westinghouse - Trip Units And Programmers
HNB212000TMV, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rated for 1200A, 50°C, suitable for NB,HNB,NBY 1200A molded case circuit breaker frame types, magnetic trip range 6000-12000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

MA2350T
Westinghouse - Trip Units And Programmers
MA2350T, Westinghouse, MA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 350A, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $1,279.63

MP20-3P-2000A-EO-DO-LI
Merlin Gerin - Insulated Case
MP20-3P-2000A-EO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame includes 2000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP12H2-3P-1000A-EO-BO-LSG
Merlin Gerin - Insulated Case
MP12H2-3P-1000A-EO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

M4RRG2000
Cutler Hammer - Rating Plug
M4RRG2000, Cutler Hammer, Magnum DS, rating plug, field installable kit for changing the sensor/rating plug rating on fixed or drawout circuit breakers, includes 1 rating plug plus 8 sensors for 4 pole breakers, rated for 2000A, suitable for use with double frame MDS air circuit breaker frame types, for use with Digitrip 220,520,520M,520MC,1150 solid state programmers
From Get Price

449D701G08
Eaton - Metering
449D701G08 / <strong>3A73103G11</strong>, Cutler Hammer, Eaton, Westinghouse, Cutler Hammer, Eaton, Westinghouse, DS Series, Metering Current Transformer 1200/5, RCT-1600, DSM-16, qty 3 required per breaker, suitable for use with DS-206, DSL-206, DS-206S, DS-206E, DS-416, DSL-416, DS-416H, DS-416S, DS-420, DSII-308, DSII-516, DSII-620 low voltage power air breakers
From Get Price

KA2090T
Westinghouse - Trip Units And Programmers
KA2090T, Westinghouse, KA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 90A, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From $393.22