- Home /
square d breaker
449,252 Results
Refine Results
In Stock
Subcategory
SORT BY

TP1616SS
General Electric - Insulated Case
<p>Insulated Case Breakers are highly customizable items. In order to provide an accurate price we need as many details as possible about the project including: current breaker status, photos of the existing breaker, and any known accessories that youll need. Please email [email protected] or submit a quote request. We have a team of industry experts standing by to assist with your needs.</p><br> TP1616SS, General Electric, Power Break I, type , 3P, 3PH, 600V, 1600A current sensor rating, 1600A frame rating, 65kA@480V, 100% equipment rated, stationary, UL listed, standard interrupting capacity, Bolt-On, for use with MicroVersaTrip RMS-9 trip programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price

MP63H2-3P-3000A-MO-DO-LS
Merlin Gerin - Insulated Case
MP63H2-3P-3000A-MO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 3000A, 3200A, 4000A, 5000A or 6300A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

CR306EXK104
General Electric - Motor Starter
CR306EXK104, General Electric, 300 Line, type , 3P, 3PH, 90A, 600V, 50 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 3, includes NEMA type 1 surface mount enclosure, equipped with overload rely to provide 17.0-35.0A with 125 max fuse rating, 125 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

MP40-3P-2500A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP40-3P-2500A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 2500A, 3000A, 3200A or 4000A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP16H2-3P-1200A-MO-DO-LS
Merlin Gerin - Insulated Case
MP16H2-3P-1200A-MO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame, includes 1200A or 1600A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP50-3P-3000A-EO-BO-LI
Merlin Gerin - Insulated Case
MP50-3P-3000A-EO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame includes 3000A, 3200A, 4000A or 5000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP40-3P-2000A-MO-BO-LI
Merlin Gerin - Insulated Case
MP40-3P-2000A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 2000A, 2500A, 3000A, 3200A or 4000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP25-3P-1200A-MO-BO-LS
Merlin Gerin - Insulated Case
MP25-3P-1200A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 1200A, 1600A, 2000A or 2500A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP40-3P-2000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP40-3P-2000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 2000A, 2500A, 3000A, 3200A or 4000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP32H-3P-1600A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP32H-3P-1600A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 1600A, 2000A, 2500A, 3000A or 3200A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP40-3P-2500A-MO-DO-LS
Merlin Gerin - Insulated Case
MP40-3P-2500A-MO-DO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame includes 2500A, 3000A, 3200A or 4000A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

CR306DXK203
General Electric - Motor Starter
CR306DXK203, General Electric, 300 Line, type , 3P, 3PH, 45A, 600V, 15 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 2-4, includes NEMA type 12 surface mount enclosure, equipped with overload rely to provide 17.0-35.0A with 125 max fuse rating, 125 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

CR306CXD605
General Electric - Motor Starter
CR306CXD605, General Electric, 300 Line, type , 3P, 3PH, 27A, 600V, 10 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 00-1, includes NEMA type 3R surface mount enclosure, equipped with overload rely to provide 0.8-1.7A with 6 max fuse rating, 15 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

CR306DXH604
General Electric - Motor Starter
CR306DXH604, General Electric, 300 Line, type , 3P, 3PH, 45A, 600V, 25 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 2, includes NEMA type 3R surface mount enclosure, equipped with overload rely to provide 13.0-27.0A with 100 max fuse rating, 100 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

MP12H-3P-1200A-EO-DO-LI
Merlin Gerin - Insulated Case
MP12H-3P-1200A-EO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

MP08H-3P-400A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP08H-3P-400A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame, includes 400A, 600A or 800A sensor rating with 400A rating plug, 3P, 3PH, 600V, 65kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price

MP32H-3P-2000A-MO-DO-LSI
Merlin Gerin - Insulated Case
MP32H-3P-2000A-MO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 2000A, 2500A, 3000A or 3200A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP40H2-3P-2000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP40H2-3P-2000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 2000A, 2500A, 3000A, 3200A or 4000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP30-3P-2000A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP30-3P-2000A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame includes 2000A, 2500A or 3000A sensor rating with 2000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

LB3225TV
Westinghouse - Trip Units And Programmers
LB3225TV, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, 50°C, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

MP25-3P-1600A-EO-BO-LSIG
Merlin Gerin - Insulated Case
MP25-3P-1600A-EO-BO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame includes 1600A, 2000A or 2500A sensor rating with 1600A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP30-3P-2500A-MO-DO-LIG
Merlin Gerin - Insulated Case
MP30-3P-2500A-MO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame includes 2500A or 3000A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

MP20H2-3P-1200A-MO-DO-LSIG
Merlin Gerin - Insulated Case
MP20H2-3P-1200A-MO-DO-LSIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2000A frame, includes 1200A, 1600A or 2000A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price

CR306DXJ604
General Electric - Motor Starter
CR306DXJ604, General Electric, 300 Line, type , 3P, 3PH, 45A, 600V, 25 hp, complete with 460V-480V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 2, includes NEMA type 3R surface mount enclosure, equipped with overload rely to provide 25-50A with 200 max fuse rating, 200 max breaker rating, suitable for use with CR306 motor control systems
From Get Price