


- Home /
square d breaker
449,252 Results
Refine Results
In Stock
Subcategory
SORT BY

AKRU-11D-30H-EO-DO-LI
General Electric - Air
AKRU-11D-30H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price

AKRT-6AE-50-EO-DO-LI
General Electric - Air
AKRT-6AE-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAV}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

GMV-1000-1-1200A-EO-6P
General Electric - Ground & Test Device
GMV-1000-1-1200A-EO-6P, General Electric, PowerVac, , Electrically Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In PowerVac Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

AKR-6S-30H-EO-BI-LI
General Electric - Air
AKR-6S-30H-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

AKR-4B-30H-EO-DO-LI
General Electric - Air
AKR-4B-30H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

UVH4LP26K
Cutler Hammer - Under Voltage Release
UVH4LP26K, Westinghouse, Cutler Hammer, Series C, type , under voltage release, 110 - 127Vdc, left side mounted, pigtail style leads, 1 undervoltage release mechanism, when installed in a circuit breaker the part number suffix is -T14, suitable for use with LDB,LD,HLD,HLDDC,LDC,CLD,CHLD,CLDC,MDL,HMDL,HMDLDC,MDLB,HMDLB,E2L,E2LM,E2M,E2MM and L-frame HMCP molded case circuit breakers
From $350.76

AKR-5A-30H-EO-DO-LI
General Electric - Air
AKR-5A-30H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 800A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with ECS Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

GTD-7.5-HK-1200A-MO-6P
ITE - Ground & Test Device
GTD-7.5-HK-1200A-MO-6P, ITE, HK Series, , Manually Operated, 3PH, 6 Bushing Design, 15000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In HK Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

AKR-11B-50-EO-DO-LI
General Electric - Air
AKR-11B-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

BQ215250RT
Cutler Hammer - Molded Case
BQ215250RT, Cutler Hammer, BQ Series, type quadplex independent trip, 2P, 1PH, 15A/50A, 120/240V, 10kA@240V, standard interrupting capacity, Feed-Thru, HACR rated, UL type BRD, install breaker only in panel positions that have notched bus stabs, complete with non-rejection tab feature, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price

AKR-4A-50H-EO-DO-LI
General Electric - Air
AKR-4A-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

SBAC5G
General Electric - Conversion Kit
SBAC5G, General Electric, Armor Clad Series, conversion kit, type , 600V max, with ground, for use with 300A-800A rated bus plugs; will convert SPECTRA or SPECTRA LOW-AMP style bus plugs into ARMOR CLAD style bus plugs; good for use with both fusible and circuit breaker style bus plugs; this equipment is suitable for use with Armor-Clad bus duct and busway systems.
From $2,137.31

AKRT-7D-50H-EO-DO-LI
General Electric - Air
AKRT-7D-50H-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 2000A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with MicroVersa Trip RMS-9 Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

CR306CXE403
General Electric - Motor Starter
CR306CXE403, General Electric, 300 Line, type , 3P, 3PH, 27A, 600V, 7.5 hp, complete with 230V-240V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 00-1, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 1.6-3.4A with 12 max fuse rating, 15 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

AKR-11D-50-EO-DO-LI
General Electric - Air
AKR-11D-50-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with EntelliGuard Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

CR306GXS423
General Electric - Motor Starter
CR306GXS423, General Electric, 300 Line, type , 3P, 3PH, 270A, 600V, 75 hp, complete with 200V-208V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 5-6, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 130.0-270.0A with 1200 max fuse rating, 800 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

MDSC163WEA081CAMNN4YPANAX
Eaton - Insulated Case
MDSC163WEA081CAMNN4YPANAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 1600A, 3-Pole, Drawout mounting, 800A rating plug, Non-DSL current limiter, 1150 LSI (120 Vac) trip unit, 110-127 Vac/Vdc shunt trip, Manual operated motor operator, No SRD, No, 4A/4B auxiliary switch, Plastic (block close and open) padlock, Counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

CR306FXP405
General Electric - Motor Starter
CR306FXP405, General Electric, 300 Line, type , 3P, 3PH, 135A, 600V, 100 hp, complete with 575V-600V 50/60Hz, AC coil, non-reversing, non-combination magnetic starter, NEMA size 4-5, includes NEMA type 4/4X surface mount enclosure, equipped with overload rely to provide 65.0-135.0A with 500 max fuse rating, 400 max breaker rating, suitable for use with CR306 motor control systems
From Get Price

QCR2010P
Cutler Hammer - Molded Case
QCR2010P, Cutler Hammer, Quicklag, type , 2P, 1PH, 10A, 120/240V, 10kA@240V, standard interrupting capacity, Bolt-On, rear-mounted, UL listed for use as branch circuit protectors, suitable for terminating two 10 AWG Quick-Connect type terminals per phase on breaker load side, complete with trip, LI - Long-Time and Instantaneous trip functions, and load side lug terminals, Thermal Magnetic, molded case miniature industrial circuit breakers
From Get Price

0209B8104G007
General Electric - Control Part
0209B8104G007 / <strong>0282A7015G011</strong>, General Electric, General Electric, PowerVac, Trip Coil *Single & Dual*, 250VDC (3 Cycle) & 125 VDC (1st Coil 5 Cycle), VB-1 0,1,2,3, ML-18, qty 1 needed per breaker, suitable for VB1 4.16-250 (1200 & 2000A), VB1 4.16-350 (1200, 2000, 3000A), VB1 7.2-500 (1200 & 2000A), VB1 13.8-500 (1200 & 2000A), VB1 13.8-750 (1200 & 2000A), VB1 13.8-1000 (1200, 2000, 3000A) breakers
From Get Price

MDSC083WEA0852NNNN2EPNNAX
Eaton - Insulated Case
MDSC083WEA0852NNNN2EPNNAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 800A, 3-Pole, Drawout mounting, 800A rating plug, Non-DSL current limiter, 520 LSI trip unit, No shunt trip, 110-125 Vac (5-sec) motor operator, No SRD, No, 2A/2B auxiliary switch, Plastic (block close and open) padlock, No counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

AKR-4S-50-EO-BI-LI
General Electric - Air
AKR-4S-50-EO-BI-LI, General Electric, Electrically Operated, Bolt-In, Low Voltage air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price

GTD-AM-150D-1200A-MO-6P
Allis Chalmers - Ground & Test Device
GTD-AM-150D-1200A-MO-6P, Allis Chalmers, Ruptair Series, , Manually Operated, 3PH, 6 Bushing Design, 5000 VAC, 1200A Frame, circuit breaker ground & test device, For Use In Ruptair Switchgear. Available in 3 or 6 pole bushing design, multiple cable connection styles, combination amperages (1200/2000/3000), electrically operated or manually operated, upon request. Additional Accessories including Grounding Cable Sets to be determined before ordering.
From Get Price

AKR-4B-75-EO-DO-LI
General Electric - Air
AKR-4B-75-EO-DO-LI, General Electric, Electrically Operated, Draw-out, Low Voltage air circuit breaker, AKR Series, Type , 3200A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with SST Solid State Overcurrent Protection, LI - Long-Time and Instantaneous trip functions, Optional Trip Functions, Current Sensor and Rating Plug Amperages available
From Get Price