


- Home /
square d breaker
449,252 Results
Refine Results
In Stock
Subcategory
SORT BY

AK-2A-50C-1600A-EO-DO
General Electric - Air
AK-2A-50C-1600A-EO-DO, General Electric, AK Series, , 3PH, 3P, 600 VAC, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKRU-8A-50-EO-DO-LSG
General Electric - Air
AKRU-8A-50-EO-DO-LSG, General Electric, Electrically Operated, Draw-out, Low Voltage Fused air circuit breaker, AKR Series, Type , 1600A Frame, 3PH, 3P, 600Vac, {Aic Rating@480VAC}@480VAC, Standard Electric Operator, Control Voltage and Wiring to be determined before ordering, with Epic MicroVersa Trip Solid State Overcurrent Protection, LSG - Long-Time, Short-Time and Ground Fault trip functions, Optional Trip Functions, Current Sensor, Rating Plug and Fuse Amperages available
From Get Price

K-2000-2000A-EO-DO
ITE - Air
K-2000-2000A-EO-DO, ITE, K-Line Series, , 3PH, 3P, 600 VAC, 2000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-2000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In K-Line Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

75H-2-3000A-EO-DO
Federal Pioneer - Air
75H-2-3000A-EO-DO, Federal Pioneer, H-2 Series, , 3PH, 3P, 600 VAC, 3000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKF-2C-2000A-EO-DO
General Electric - Air
AKF-2C-2000A-EO-DO, General Electric, AKF Series, , 2PH, 2P, 480 VDC, 2000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-2000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-6A-50-1600A-EO-DO
General Electric - Air
AK-6A-50-1600A-EO-DO, General Electric, AK Series, , 3PH, 3P, 600 600, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-6AE-30-800A-EO-DO
General Electric - Air
AKR-6AE-30-800A-EO-DO, General Electric, AKR Series, , 2PH, 2P, 300 VDC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-6 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-8D-30H-800A-EO-DO
General Electric - Air
AKR-8D-30H-800A-EO-DO, General Electric, AKR Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-8 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-6A-30-800A-EO-DO
General Electric - Air
AKR-6A-30-800A-EO-DO, General Electric, AKR Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-6 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-7D-30S-600A-MO-DO
Westinghouse - Air
AKR-7D-30S-600A-MO-DO, Westinghouse, AKR Series, , 3PH, 3P, 600 VAC, 600 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-8 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKRU-5A-50-1600A-MO-DO
General Electric - Air
AKRU-5A-50-1600A-MO-DO, General Electric, AKRU Series, , 3PH, 3P, 600 VAC, 1600 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-6 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-2-100-4000A-EO-DO
General Electric - Air
AK-2-100-4000A-EO-DO, General Electric, AK Series, , 3PH, 3P, 600 VAC, 4000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-4000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKSU-6A-50-1600A-MO-DO
General Electric - Air
AKSU-6A-50-1600A-MO-DO, General Electric, AKSU Series, , 3PH, 3P, 600 VAC, 1600 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

DB-15-225A-EO-DO
Westinghouse - Air
DB-15-225A-EO-DO, Westinghouse, DB Series, , 3PH, 3P, 600 VAC, 225 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-225 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In De-ion DB Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-7S-30-800A-EO-BO
General Electric - Air
AKR-7S-30-800A-EO-BO, General Electric, AKR Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Bolt-On, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Stationary Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From $33,400.00

AKR-4C-75-3200A-EO-DO
General Electric - Air
AKR-4C-75-3200A-EO-DO, General Electric, AKR Series, , 3PH, 3P, 600 VAC, 3200 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3200 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-6 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

DB-25-600A-MO-BO
Westinghouse - Air
DB-25-600A-MO-BO, Westinghouse, DB Series, , 3PH, 3P, 600 VAC, 600 Frame, Manually Operated, Bolt-On, Low Voltage air circuit breaker, 15A-600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In De-ion DB Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-4A-50-1600A-EO-DO
General Electric - Air
AK-4A-50-1600A-EO-DO, General Electric, AK Series, , 3PH, 3P, 600 600, 1600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-1600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AKR-9D-30H-800A-EO-DO
General Electric - Air
AKR-9D-30H-800A-EO-DO, General Electric, AKR Series, , 3PH, 3P, 600 VAC, 800 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD-8 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

FMS-5-30-800A-MO-DO
Federal Pacific - Air
FMS-5-30-800A-MO-DO, Federal Pacific, FMS Series, , 3PH, 3P, 600 VAC, 800 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-800 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-2A-75-3000A-EO-DO
General Electric - Air
AK-2A-75-3000A-EO-DO, General Electric, AK Series, , 3PH, 3P, 600 VAC, 3000 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

MDSC164WEA161GRNAN6YHANAX
Eaton - Insulated Case
MDSC164WEA161GRNAN6YHANAX, Cutler Hammer, Eaton, Magnum DS Type , Standard frame, 100kA@635V interrupting rating, 1600A, 4-Pole, Drawout mounting, 1600A rating plug, Non-DSL current limiter, 1150 LSIG (120 Vac) trip unit, 208-240 Vac/Vdc shunt trip, 110-125 Vac (5-sec) motor operator, 110-127 Vac/Vdc SRD, No, 6A/6B auxiliary switch, Plastic (block close only) padlock, Counter - no lock key lock, low voltage power insulated case circuit breaker
From Get Price

AKF-1B-600A-EO-DO
General Electric - Air
AKF-1B-600A-EO-DO, General Electric, AKF Series, , 2PH, 2P, 250 VDC, 600 Frame, Electrically Operated, Draw-Out, Low Voltage air circuit breaker, 15A-600 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models, For Use In AKD Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price

AK-5A-75-3000A-MO-DO
General Electric - Air
AK-5A-75-3000A-MO-DO, General Electric, AK Series, , 3PH, 3P, 600 VAC, 3000 Frame, Manually Operated, Draw-Out, Low Voltage air circuit breaker, 15A-3000 A sensor rating, Available in LS, LI, LG, LSI, LIG, LSG, or LSIG Trip Functions in multiple Trip Unit Models For Use In AKD-5 Switchgear. Operating Voltage, Control Voltages, Wiring, Trip Functions, Current Sensor, Rating Plug, and Additional Accessories to be determined before ordering.
From Get Price