Limited Stock
MPA31F25N0000
MPA31F25N0000
General Electric - Insulated Case
MPA31F25N0000, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches and Mpro-27 trip unit, 3P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HDK261253
HDK261253
Schneider Electric - Molded Case
HDK261253, Schneider Electric, Square D, PowerPact, type , 2P, B & A phase connection, 1PH, 125A, 600V, 18kA@480V, UL listed, standard interrupting capacity, reverse I-Line Style Plug-In, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
EEHFD220080SB2
EEHFD220080SB2
Cutler Hammer - Mounting Hardware
EEHFD220080SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 80A, AC phase connection, 240V max, Copper, Single Branch mounting style, suitable for use with EHD,FDB,FD,HFD,FDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
WLH1F312JE
WLH1F312JE
Siemens - Insulated Case
WLH1F312JE, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 500A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
PKA36040CU43AE1BD
PKA36040CU43AE1BD
Schneider Electric - Molded Case
PKA36040CU43AE1BD, Square D, Schneider Electric, PowerPact, type , 3P, ABC phase connection, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, 100% rated, complete with 1A/1B overcurrent trip switch, modbus communications, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
E3V-A20-4P-800A-BO-EO-LSIG
E3V-A20-4P-800A-BO-EO-LSIG
ABB - Insulated Case
E3V-A20-4P-800A-BO-EO-LSIG, ABB, EMax, type , 4P, 3PH, 2000A frame, 800A rating plug, 600V, 125kA@480V, fixed mount/Bolt-On, electrically operated, Solid State electronic with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SEHF36800LSES3F4
SEHF36800LSES3F4
Square D - Insulated Case
SEHF36800LSES3F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0222NMNR4ENHNSX
MDN4083LEA0222NMNR4ENHNSX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNR4ENHNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
LGX463032WVH08
LGX463032WVH08
Cutler Hammer - Molded Case
LGX463032WVH08, Cutler Hammer, Series G, type , 4P, 3PH, 630A, 600V, 200kA@480V, current limiting, for Marine applications 50°C, not UL listed, Bolt-On, complete with interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
PLF34100CU64AE1AA
PLF34100CU64AE1AA
Square D - Molded Case
PLF34100CU64AE1AA, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1000A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B auxiliary switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
5925-00-064-7834
5925-00-064-7834
Eaton - Trip Units And Programmers
5925-00-064-7834, Eaton, Naval, Thermal Magnetic trip units and programmers, type -A250, 2P, 225A, 500Vac/250Vdc, 650-1300 instantaneous trip setting, LI - Long-Time and Instantaneous trip functions, suitable for use with AQB-A250 circuit breakers for naval shipboard use
From Get Price
Limited Stock
PJF36025CU63BE1AB
PJF36025CU63BE1AB
Schneider Electric - Molded Case
PJF36025CU63BE1AB, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 250A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
PDG32K0400E2ML
PDG32K0400E2ML
Cutler Hammer - Molded Case
PDG32K0400E2ML, Cutler Hammer, Eaton, Power Defense, type , 1PH, 2P, 600V, 400A, 50kA@480V, Bolt-On, load side lug terminals, complete with PXR20 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions and Modbus RTU & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
IZMB2-4-A1600
IZMB2-4-A1600
Klockner Moeller - Insulated Case
IZMB2-4-A1600, Klockner Moeller, IZM Series, type , 4P, 3PH, 1600A, 690V, 55kA@415V, basic switching capacity, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers for distribution circuit protection
From Get Price
Limited Stock
MDN4083LEA0122NMNNNYNAMAX
MDN4083LEA0122NMNNNYNAMAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNYNAMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNE4NNANWX
MDN4083LEA0222NMNE4NNANWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE4NNANWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SED36800E8
SED36800E8
Square D - Insulated Case
SED36800E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MPA41F16V4420
MPA41F16V4420
General Electric - Insulated Case
MPA41F16V4420, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 220/250V dc/ac motor operator, 220/250V dc/ac closing coil and 48V dc shunt trip, 4P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
LLP34400WU44X
LLP34400WU44X
Square D - Molded Case
LLP34400WU44X, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 400A, 480V, 100kA@480V, UL listed, Bolt-On, suitable for reverse connection, complete with non-interchangeable mission critical ammeter 6.3A-W trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
PDG32G0250E4RN
PDG32G0250E4RN
Cutler Hammer - Molded Case
PDG32G0250E4RN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 250A, 35kA@480V, Bolt-On, no lug terminals, complete with PXR20 trip with ARMS LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
WLH1F312EV
WLH1F312EV
Siemens - Insulated Case
WLH1F312EV, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 1200A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU776 programmer, LSI - Long-Time, Short-Time and Instantaneous trip functions and 315A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SEHF362000LIES6A4
SEHF362000LIES6A4
Schneider Electric - Insulated Case
SEHF362000LIES6A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNN4YNYMSX
MDN4083LEA0622NMNN4YNYMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNN4YNYMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNN2YNNCAX
MDN4083LEA0822NMNN2YNNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNN2YNNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price