1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHF361000LIES8E8
SEHF361000LIES8E8
Square D - Insulated Case
SEHF361000LIES8E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHF36350LSGES8E8
SEHF36350LSGES8E8
Square D - Insulated Case
SEHF36350LSGES8E8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
E6V-A50-3P-5000A-BO-EO-LI
E6V-A50-3P-5000A-BO-EO-LI
ABB - Insulated Case
E6V-A50-3P-5000A-BO-EO-LI, ABB, EMax, type , 3P, 3PH, 5000A frame, 5000A rating plug, 600V, 125kA@480V, fixed/Bolt-On, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
EEFDC420150SB2
EEFDC420150SB2
Cutler Hammer - Mounting Hardware
EEFDC420150SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 150A, ABL or BCR phase connection, 240V max, Copper, Single Branch mounting style, suitable for use with FDB,FD,HFD,FDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNJNNNKDPX
MDN4083LEA0122NMNJNNNKDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJNNNKDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNN2NNKMSX
MDN4083LEA0622NMNN2NNKMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNN2NNKMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PCC32000FM
PCC32000FM
Westinghouse - Insulated Case
PCC32000FM, FRAME ONLY, Westinghouse, SELTRONIC, type , 3P, 3PH, 2000A, 600V, 100kA@480V, UL listed, Bolt-On, rear connected, 100% rated, frame only, complete with I - Instantaneous trip functions, rating plug not included, Magnetic Only electronic, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNN2EHNDPX
MDN4083LEA0122NMNN2EHNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2EHNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNG4ENCDCX
MDN4083LEA0522NMNG4ENCDCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG4ENCDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEHF36350LSES3B4
SEHF36350LSES3B4
Schneider Electric - Insulated Case
SEHF36350LSES3B4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
TC2525SSE1
TC2525SSE1
General Electric - Insulated Case
TC2525SSE1, General Electric, Power Break I, type , 3P, 3PH, 600V, 2500A current sensor rating, 2500A frame rating, 100kA@480V, 100% equipment rated, UL listed, standard interrupting capacity, suitable for reverse feed, Draw-Out, for use with MicroVersaTrip RMS-9 programmer, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, electrically operated with 120VAC electrical motor operator, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
SED361000LSIGES4
SED361000LSIGES4
Schneider Electric - Insulated Case
SED361000LSIGES4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD362000LSIES7C8
SEHD362000LSIES7C8
Schneider Electric - Insulated Case
SEHD362000LSIES7C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PKP36025U33ARD10
PKP36025U33ARD10
Schneider Electric - Molded Case
PKP36025U33ARD10, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 600V, 50kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with direct mounted standard black handle, micrologic interchangeable standard 5.0 trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNH2YNNDPX
MDN4083LEA0322NMNH2YNNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNH2YNNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0722NMNF2NNCMAX
MDN4083LEA0722NMNF2NNCMAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNF2NNCMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SEHD362000LIGES7C4
SEHD362000LIGES7C4
Schneider Electric - Insulated Case
SEHD362000LIGES7C4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNC2YNRCSX
MDN4083LEA0722NMNC2YNRCSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNC2YNRCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
50H-3-3000A-EO-BO-LS
50H-3-3000A-EO-BO-LS
Federal Pioneer - Air
50H-3-3000A-EO-BO-LS, Federal Pioneer, H-3 Series, type , 3000A frame size, electrically operated/Bolt-On, 3P, 3PH, 3000A, 600V, 50kA@480V, available with multiple trip unit options, LS - Long-Time and Short-Time trip functions, Solid State electronic, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNN4YNHMCX
MDN4083LEA0722NMNN4YNHMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4YNHMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNN4YNKNSX
MDN4083LEA0722NMNN4YNKNSX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNN4YNKNSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
PEEN4ATEM0250
PEEN4ATEM0250
General Electric - Molded Case
PEEN4ATEM0250, General Electric, GuardEon, type , 3PH, 4P, 600V, 45-250A, 65kA@480V, 100% UL rated, front connection/Feed-Thru, toggle mechanism, complete with PremEon G advanced metering interchangeable trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with switchable GF, Solid State electronic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MPA41F20V1310
MPA41F20V1310
General Electric - Insulated Case
MPA41F20V1310, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc motor operator, 110/130V dc/ac closing coil and 24/30V dc shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNA4YNRCWX
MDN4083LEA0822NMNA4YNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNA4YNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price