HMCP250C5S03
HMCP250C5S03
Eaton - Molded Case
HMCP250C5S03, Westinghouse, Cutler Hammer, Eaton, Series C, type , J Frame, 3P, 3PH, 250A, 600V, 35kA@480V, Feed-Thru, complete with left-pole mounted 12-24Vac/dc right side shunt trip, I - Instantaneous Protection Only and standard line & load side lug terminals, magnetic range 450-900A, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
FWCF4125L
FWCF4125L
Westinghouse - Molded Case
FWCF4125L, Cutler Hammer, Eaton, Westinghouse, Series C, type , 4P with neutral, 3PH, 125A, 690V, 100kA@415V, ultra high interrupting capacity, Feed-Thru, complete with non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
436017
436017
General Electric - Molded Case
436017 General Electric Record Plus, type , FE250 frame, FEN436TG160KF, 4P, 3PH, 160A, 690V, 50kA@415V, Feed-Thru, complete with 3-pole interchangeable GTM trip, LI - Long-Time and Instantaneous trip functions, generator Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
SPB100-3P-400A-EO-DO-LS
SPB100-3P-400A-EO-DO-LS
Cutler Hammer - Insulated Case
SPB100-3P-400A-EO-DO-LS, Cutler Hammer, Systems Pow-R, type , 800A frame size, 3P, 3PH, 400A, 600V, 100kA@480V, standard interrupting capacity, Draw-Out, electrically operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LS - Long-Time and Short-Time trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
SHD6G9L2U
SHD6G9L2U
General Electric - Insulated Case
SHD6G9L2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering, RELT & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
In Stock
XT7LQ380CEFF000XXX
XT7LQ380CEFF000XXX
ABB - Molded Case
XT7LQ380CEFF000XXX, ABB, SACE Tmax XT, type , UL 100% rated, 3PH, 3P, 600V, 800A, 100kA@480V, , front terminals, complete with Ekip Dip LS/I trip, Ekip LS/I (Electronic, LS/I protection), molded case circuit breakers; 1SDA102995R1 + 1SDA107723R1 global reference
From $5,986.80
Limited Stock
SE2C080
SE2C080
Sylvania - Molded Case
SE2C080, Challenger, Sylvania, SE Series, type SE, 2P, 1PH, 80A, 240V, 14kA@240V, standard interrupting capacity, 40ºC, Bolt-On, complete with trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers; this breaker is now obsolete; however, we still stock them
From Get Price
Limited Stock
FDE45TC080GF
FDE45TC080GF
General Electric - Molded Case
FDE45TC080GF General Electric Record Plus, type , FDE160 frame, 430299, 4P, 3PH, 80A, 690V, 25kA@415V, Feed-Thru, complete with interchangeable LTM trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MP63H-3P-6300A-MO-DO-LI
MP63H-3P-6300A-MO-DO-LI
Merlin Gerin - Insulated Case
MP63H-3P-6300A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
In Stock
BQD33000S01
BQD33000S01
Siemens - Molded Case
BQD33000S01, Siemens, BQD Series, type , 3P, 3PH, 30A, 277/480V, 14kA@480V, standard interrupting capacity, 40°C, Bolt-On, 120Vac shunt trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers
From $496.88
In Stock
JS360125A
JS360125A
Thomas & Betts - Molded Case
JS360125A, Thomas & Betts, J Frame, type , 3P, 3PH, 600V, 125A, 35kA@480V, standard interrupting capacity, line & load side lug terminals, Feed-Thru, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers
From $753.20
Limited Stock
MDN4083LEA0222NMNE2YNCNAX
MDN4083LEA0222NMNE2YNCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE2YNCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
EGE4035FFGVH09
EGE4035FFGVH09
Cutler Hammer - Molded Case
EGE4035FFGVH09, Cutler Hammer, Series G, type , 4P, 3PH, 35A, 600V, 25kA@480V, standard interrupting capacity, for Naval applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
In Stock
QBGFEP1015W1
QBGFEP1015W1
Eaton - Molded Case
QBGFEP1015W1, Cutler Hammer, Eaton, Quicklag, type , 1P, 1PH, 15A, 120V, 10kA@120V, standard interrupting capacity, 40°C, Bolt-On, 30 mA sensitivity, complete with ground fault equipment protection and bell alarm, LI - Long-Time and Instantaneous trip functions & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From $620.76
Limited Stock
SSB1G159C
SSB1G159C
General Electric - Insulated Case
SSB1G159C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, full metering, RELT, modbus communication & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
S07F60
S07F60
ITE - Shunt Trip
S07F60, ITE, Siemens, shunt trip, VDC, suitable for F6,HF6,FJ6 circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNN2YNHDWX
MDN4083LEA0122NMNN2YNHDWX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2YNHDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0222NMNH4NNHDCX
MDN4083LEA0222NMNH4NNHDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH4NNHDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNC4ENKCCX
MDN4083LEA0622NMNC4ENKCCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4ENKCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNK4NNCMCX
MDN4083LEA0822NMNK4NNCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK4NNCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0422NMNCNYNYCSX
MDN4083LEA0422NMNCNYNYCSX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNCNYNYCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
S06HP2R0
S06HP2R0
ITE - Shunt Trip
S06HP2R0, ITE, K Frame, shunt trip, 600V, suitable for use with KP,HP,CP,HR,HK circuit breakers; these shunts are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0722NMNR2NNNDPX
MDN4083LEA0722NMNR2NNNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNR2NNNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
E3S-A25-3P-400A-DO-MO-LI
E3S-A25-3P-400A-DO-MO-LI
ABB - Insulated Case
E3S-A25-3P-400A-DO-MO-LI, ABB, EMax, type , 3P, 3PH, 2500A frame, 400A rating plug, 600V, 65kA@480V, Draw-Out, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price