1. Home / 
  2. breaker

SORT BY
Limited Stock
SHD1G1E2B
SHD1G1E2B
General Electric - Insulated Case
SHD1G1E2B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, RELT & modbus communication features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD5G8K8W
SHD5G8K8W
General Electric - Insulated Case
SHD5G8K8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF1G3K1I
SHF1G3K1I
General Electric - Insulated Case
SHF1G3K1I, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering & ZSI features and 450A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD5G8F81
SHD5G8F81
General Electric - Insulated Case
SHD5G8F81, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 150kA@480V, high interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G3M1H
SHD1G3M1H
General Electric - Insulated Case
SHD1G3M1H, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD3G6F2U
SHD3G6F2U
General Electric - Insulated Case
SHD3G6F2U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G7C81
SSD4G7C81
General Electric - Insulated Case
SSD4G7C81, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & modbus communication features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD3G6B1T
SHD3G6B1T
General Electric - Insulated Case
SHD3G6B1T, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD2G5B1T
SHD2G5B1T
General Electric - Insulated Case
SHD2G5B1T, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 1500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD2G591R
SSD2G591R
General Electric - Insulated Case
SSD2G591R, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G7F1U
SSD4G7F1U
General Electric - Insulated Case
SSD4G7F1U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G2L8D
SHD1G2L8D
General Electric - Insulated Case
SHD1G2L8D, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 225A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD5G8K8W
SSD5G8K8W
General Electric - Insulated Case
SSD5G8K8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Draw-Out, 3000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G3L8J
SSD1G3L8J
General Electric - Insulated Case
SSD1G3L8J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & ZSI features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD3G6X6M
SSD3G6X6M
General Electric - Insulated Case
SSD3G6X6M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G1L1A
SSD1G1L1A
General Electric - Insulated Case
SSD1G1L1A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & ZSI features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G1B1A
SHD1G1B1A
General Electric - Insulated Case
SHD1G1B1A, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & modbus communication features and 100A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G3F8F
SSD1G3F8F
General Electric - Insulated Case
SSD1G3F8F, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, full metering & modbus communication features and 300A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G2Y1C
SSD1G2Y1C
General Electric - Insulated Case
SSD1G2Y1C, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication, relays & ZSI features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD4G7J11
SSD4G7J11
General Electric - Insulated Case
SSD4G7J11, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, full metering, modbus communication & relays features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD3G6X6W
SSD3G6X6W
General Electric - Insulated Case
SSD3G6X6W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSB1G2Z1N
SSB1G2Z1N
General Electric - Insulated Case
SSB1G2Z1N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SSD1G3A2H
SSD1G3A2H
General Electric - Insulated Case
SSD1G3A2H, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & RELT features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHD1G3X6N
SHD1G3X6N
General Electric - Insulated Case
SHD1G3X6N, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, current metering features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price