1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
MPA31F20V0140
MPA31F20V0140
General Electric - Insulated Case
MPA31F20V0140, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-50L trip unit, 24/30V dc closing coil and 220/250V dc/ac shunt trip, 3P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
SSD3G629W
SSD3G629W
General Electric - Insulated Case
SSD3G629W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT, modbus communication & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF362500LSGES5D5
SEHF362500LSGES5D5
Square D - Insulated Case
SEHF362500LSGES5D5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
436356
436356
General Electric - Molded Case
436356, General Electric, Record Plus Mag Break, type , FE160 frame, 4P, 3PH, 125A, 690V, 50kA@415V, UL listed, standard interrupting capacity, Feed-Thru, complete with I - Instantaneous protection only, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNC2NNRDAX
MDN4083LEA0122NMNC2NNRDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2NNRDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNN4NNAMCX
MDN4083LEA0322NMNN4NNAMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNN4NNAMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0622NMNCNENNNAX
MDN4083LEA0622NMNCNENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNCNENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
KT6M3
KT6M3
ABB - Motor Operator
KT6M3, ABB, SACE Tmax, type , stored energy motor operator, 380-380VAC, suitable for use with T6N,T6S,T6H,T6L molded case circuit breaker frame types
From Get Price
Limited Stock
E6X-A40-4P-3000A-DO-EO-LI
E6X-A40-4P-3000A-DO-EO-LI
ABB - Insulated Case
E6X-A40-4P-3000A-DO-EO-LI, ABB, EMax, type , 4P, 3PH, 4000A frame, 3000A rating plug, 600V, 200kA@480V, Draw-Out, electrically operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
SPB100-3P-2500A-MO-BO-LS
SPB100-3P-2500A-MO-BO-LS
Cutler Hammer - Insulated Case
SPB100-3P-2500A-MO-BO-LS, Cutler Hammer, Systems Pow-R, type , 3000A frame size, 3P, 3PH, 2500A, 600V, 100kA@480V, standard interrupting capacity, Bolt-On, manually operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LS - Long-Time and Short-Time trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
LGC425032WVH08
LGC425032WVH08
Cutler Hammer - Molded Case
LGC425032WVH08, Cutler Hammer, Series G, type , 4P, 3PH, 250A, 600V, 100kA@480V, current limiting, for Marine applications 50°C, not UL listed, Bolt-On, complete with interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, lugs not included, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
WLH1F320LK
WLH1F320LK
Siemens - Insulated Case
WLH1F320LK, Siemens, WL Series, type , frame size I, fixed mount, 3P, 3PH, 2000A, 600V, 85kA@480V, UL listed, standard interrupting capacity, Bolt-On, complete with solid state ETU748 programmer + WLLCD48 LCD display, LS - Long-Time and Short-Time trip functions and 630A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
J108LIT2
J108LIT2
General Electric - Trip Units And Programmers
J108LIT2, General Electric, Power Plus, trip units/trip units and programmers, 800A current sensor rating, Solid State electronic, complete with LI - Long-Time and Instantaneous trip functions and target module feature with ground fault, suitable for use with 1600A frame WavePro WPS,WPH,WPF,WPX low voltage power circuit breakers
From Get Price
Limited Stock
SEF361600LSIGES5A8
SEF361600LSIGES5A8
Schneider Electric - Insulated Case
SEF361600LSIGES5A8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNC2ENRDPX
MDN4083LEA0122NMNC2ENRDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC2ENRDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNRNENKMCX
MDN4083LEA0522NMNRNENKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNRNENKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SHD1G1J3B
SHD1G1J3B
General Electric - Insulated Case
SHD1G1J3B, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MPA41F2504200
MPA41F2504200
General Electric - Insulated Case
MPA41F2504200, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 220/250V dc/ac motor operator and 48V dc closing coil, 4P, 3PH, 2500A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, insulated case circuit breakers
From Get Price
Limited Stock
PGL36100CU41AE1BD
PGL36100CU41AE1BD
Schneider Electric - Molded Case
PGL36100CU41AE1BD, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1000A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Feed-Thru, 100% rated, complete with 1A/1B overcurrent trip switch, modbus communications, micrologic interchangeable ammeter 3.0A trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHD362000LSGES4A8
SEHD362000LSGES4A8
Square D - Insulated Case
SEHD362000LSGES4A8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
PLM34000S80BD
PLM34000S80BD
Square D - Molded Case
PLM34000S80BD, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 800A, 480V, 100kA@480V, very UL listed, high interrupting capacity, Bolt-On, complete with 1A/1B overcurrent trip switch, NA - No Overcurrent Protection, Non-Automatic switch, line side lug terminals, molded case circuit breakers
From Get Price
Limited Stock
SHB6G9392
SHB6G9392
General Electric - Insulated Case
SHB6G9392, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0522NMNFNNNHCSX
MDN4083LEA0522NMNFNNNHCSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNFNNNHCSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEF361600LSIGES1B8
SEF361600LSIGES1B8
Square D - Insulated Case
SEF361600LSIGES1B8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price