MDN4083LEA0722NMNJ2YNACWX
MDN4083LEA0722NMNJ2YNACWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ2YNACWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
FEV36TA125KF
FEV36TA125KF
General Electric - Molded Case
FEV36TA125KF General Electric Record Plus, type , FE250 frame, 3P, 3PH, 125A, 690V, 36kA@415V, Feed-Thru, complete with interchangeable LTM trip, LI - Long-Time and Instantaneous trip functions, line Thermal Magnetic, molded case circuit breakers
From Get Price
In Stock
HLA36150ABURYP
HLA36150ABURYP
Square D - Molded Case
HLA36150ABURYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 150A, 600V, 100kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, 125 VDC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $3,769.92
Limited Stock
MDN4083LEA0722NMNKNYMNCWX
MDN4083LEA0722NMNKNYMNCWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNKNYMNCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed metal padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
PJP36080U64BE1BD
PJP36080U64BE1BD
Square D - Molded Case
PJP36080U64BE1BD, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 800A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with 1A/1B overcurrent trip switch, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
In Stock
HGA36150U33XABBHSR
HGA36150U33XABBHSR
Square D - Molded Case
HGA36150U33XABBHSR, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 150A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2S non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B aux switch, alarm switch low-level, 125 VDC shunt trip, molded case circuit breakers
From $3,564.75
Limited Stock
REF3L005
REF3L005
Miami Breaker - Molded Case
REF3L005, Miami Breaker, REF Series, type , 3P, 3PH, 5A, 600V, 14kA@480V, standard interrupting capacity, Bolt-On, complete with I - Instantaneous protection only and load side lug terminals, low magnetic range, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
PGP46100CU44AAB
PGP46100CU44AAB
Square D - Molded Case
PGP46100CU44AAB, Schneider Electric, Square D, PowerPact, type , 4P, 3PH, 1000A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNX2NHNNCX
MDN4083LEA0822NMNX2NHNNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNX2NHNNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0722NMNNNYNYNWX
MDN4083LEA0722NMNNNYNYNWX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNNNYNYNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SED363200LIS3
SED363200LIS3
Schneider Electric - Insulated Case
SED363200LIS3, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, complete with 48VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SGHB36CB6300C
SGHB36CB6300C
General Electric - Molded Case
SGHB36CB6300C, General Electric, Spectra Series, type , 3P, 3PH, 300A, 600V, 35kA@480V, standard interrupting capacity, Bolt-On, complete with SRPG600B300 rating plug, suitable for reverse fed applications, UL listed, complete with interchangeable MVT, MicroVersaTrip, PM trip unit with LSIT - Long-Time, Short-Time, Instantaneous and Targets trip functions, lugs not included, Solid State Electronic, molded case circuit breakers
From Get Price
In Stock
HDL36060U44XAEBKUJYP
HDL36060U44XAEBKUJYP
Square D - Molded Case
HDL36060U44XAEBKUJYP, Square D, PowerPact, type , 3P, 3PH, 60A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, micrologic ammeter non-interchangeable trip with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, complete with 1A/1B low-level aux switch, alarm switch and overcurrent trip switch, low-level, 525/600 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,476.62
Limited Stock
MDN4083LEA0822NMNXNNNHDPX
MDN4083LEA0822NMNXNNNHDPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNXNNNHDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
In Stock
HRA36100U31XAAUR
HRA36100U31XAAUR
Square D - Molded Case
HRA36100U31XAAUR, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 200kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse connection, can be used for 2P applications, micrologic standard 3.2 non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Solid State electronic, complete with 1A/1B aux switch, 125 VDC under voltage release (UVR), molded case circuit breakers
From $3,990.00
Limited Stock
FAR26030BC
FAR26030BC
Square D - Molded Case
FAR26030BC, Square D, I-Line, type , 2P, 1PH, 30A, 600V, 18kA@480V, standard interrupting rating, 40ºC, I-Line Style Plug-In, B & C phase circuit configuration, with I-Line drawout connectors and plug-on connector blocks sold separately, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0222NMNR2NNKMWX
MDN4083LEA0222NMNR2NNKMWX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNR2NNKMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SED361800LIGES3C8
SED361800LIGES3C8
Square D - Insulated Case
SED361800LIGES3C8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1800A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
In Stock
HDA260402ABBHUAYP
HDA260402ABBHUAYP
Square D - Molded Case
HDA260402ABBHUAYP, Square D, PowerPact, type , 1PH, 2P, A & C phase connection, 40A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch low-level, 120 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $1,615.32
Limited Stock
PDF54K0800E3WN
PDF54K0800E3WN
Cutler Hammer - Molded Case
PDF54K0800E3WN, Cutler Hammer, Eaton, Power Defense, type , 3PH, 4P, 600V, 800A, 50kA@480V, Bolt-On, no terminals, complete with PXR20 trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with relays, modbus & ZSI option, Solid State electronic, molded case circuit breakers; globally rated with 100% UL rating
From Get Price
Limited Stock
SEF363200LSB8
SEF363200LSB8
Schneider Electric - Insulated Case
SEF363200LSB8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, complete with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
In Stock
HJA36060AEBCUDYP
HJA36060AEBCUDYP
Square D - Molded Case
HJA36060AEBCUDYP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 60A, 600V, 65kA@480V, current limiting, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B low-level aux switch, alarm switch, 208/277 VAC under voltage release (UVR), "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,050.02
In Stock
HDL26040ABBCSP
HDL26040ABBCSP
Square D - Molded Case
HDL26040ABBCSP, Square D, PowerPact, type , 2P, 1PH, 40A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 2A/2B aux switch, alarm switch, 48 VDC shunt trip, molded case circuit breakers
From $1,134.00
Limited Stock
LJL46600CU54X
LJL46600CU54X
Square D - Molded Case
LJL46600CU54X, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 600A, 600V, 65kA@480V, UL listed, current limiting, Feed-Thru, 100% rated, complete with non-interchangeable micrologic energy 6.3E trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price