1. Home / 
  2. breaker

SORT BY
Limited Stock
PKD46040U63AE1YP
PKD46040U63AE1YP
Schneider Electric - Molded Case
PKD46040U63AE1YP, Square D, Schneider Electric, PowerPact, type , 4P, 3PH, 400A, 600V, 50kA@480V, UL listed, high interrupting capacity, Draw-Out, complete with fixed handle padlocking device, micrologic interchangeable power 5.0P trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNK2YNYNPX
MDN4083LEA0722NMNK2YNYNPX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK2YNYNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0322NMNNNNNYMCX
MDN4083LEA0322NMNNNNNYMCX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNNNNNYMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PDG32K0125D5DN
PDG32K0125D5DN
Cutler Hammer - Molded Case
PDG32K0125D5DN, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 125A, 50kA@480V, Bolt-On, no lug terminals, complete with PXR20D ARMS trip with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and Modbus RTU, CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SSF4G4L9P
SSF4G4L9P
General Electric - Insulated Case
SSF4G4L9P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, RELT & ZSI features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF36600LSIES8F4
SEHF36600LSIES8F4
Square D - Insulated Case
SEHF36600LSIES8F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHB4G662R
SHB4G662R
General Electric - Insulated Case
SHB4G662R, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering, modbus communcation & ZSI features and 1200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0622NMNX2NNNNPX
MDN4083LEA0622NMNX2NNNNPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNX2NNNNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNA4YCNMSX
MDN4083LEA0622NMNA4YCNMSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNA4YCNMSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHD36800ES7D4
SEHD36800ES7D4
Square D - Insulated Case
SEHD36800ES7D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 800A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MPA31F16N4450
MPA31F16N4450
General Electric - Insulated Case
MPA31F16N4450, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 220/250V dc/ac motor operator, 220/250V dc/ac closing coil, 380/400V ac shunt trip, 3P, 3PH, 1600A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNRNENADPX
MDN4083LEA0322NMNRNENADPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNRNENADPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
EGS1063FFGVH08
EGS1063FFGVH08
Cutler Hammer - Molded Case
EGS1063FFGVH08, Cutler Hammer, Series G, type , 1P, 1PH, 63A, 240V, 85kA@240V, standard interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
PJP36100CU43AAB
PJP36100CU43AAB
Schneider Electric - Molded Case
PJP36100CU43AAB, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 1000A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, 100% rated, complete with 2A/2B auxiliary switch, micrologic interchangeable ammeter 5.0A trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MPA32F40W1020
MPA32F40W1020
General Electric - Insulated Case
MPA32F40W1020, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 24/30V dc motor operator and 48V dc shunt trip, 3P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNR4ENLDPX
MDN4083LEA0522NMNR4ENLDPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNR4ENLDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
LA-4000F-MO-DO-LI
LA-4000F-MO-DO-LI
Siemens-Allis - Air
LA-4000F-MO-DO-LI, Siemens-Allis, LA Series, type , 4000A frame size, NEMA class J or L integrally-mounted current limiting fuses, manually operated/Draw-Out, 3P, 3PH, 4000A current sensor rating, 600V, 200kA@480V, originally supplied with StaticTrip II or LimiTrip overcurrent trip devices but can also be retrofitted with a modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
E4V-A36-3P-1000A-DO-MO-LI
E4V-A36-3P-1000A-DO-MO-LI
ABB - Insulated Case
E4V-A36-3P-1000A-DO-MO-LI, ABB, EMax, type , 3P, 3PH, 3600A frame, 1000A rating plug, 600V, 100kA@480V, Draw-Out, manually operated, Solid State electronic with LI - Long-Time and Instantaneous trip functions, low voltage power insulated case circuit breakers; if accessories are needed, please call our Sales Team for assistance
From Get Price
Limited Stock
MDN4083LEA0222NMNANNNKDAX
MDN4083LEA0222NMNANNNKDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNANNNKDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MGA266002AA
MGA266002AA
Square D - Molded Case
MGA266002AA, Schneider Electric, Square D, PowerPact, type , 2P, A & C phase connection, 1PH, 600A, 600V, 35kA@480V, UL listed, high interrupting capacity, I-Line Style Plug-In, complete with 1A/1B aux switch, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State, molded case circuit breakers
From Get Price
Limited Stock
SKSS3408L3N6
SKSS3408L3N6
General Electric - Molded Case
SKSS3408L3N6, General Electric, Spectra Series, type , 3P, 3PH, 800A, 480V, 100kA@480V, standard interrupting capacity, 100% rated, UL listed, suitable for reverse fed applications, complete with microEntelliGuard trip unit with LSIZ - Long-Time, Short-Time, Instantaneous and ZSI trip functions with extended instantaneous, advanced metering + modbus + waveform capture advanced features, Solid State with RELT and neutral protection, molded case circuit breakers
From Get Price
Limited Stock
PGD46040CU73AE1RE10
PGD46040CU73AE1RE10
Square D - Molded Case
PGD46040CU73AE1RE10, Schneider Electric, Square D, PowerPact, type , 4P, 3PH, 400A, 600V, 35kA@480V, UL listed, standard interrupting capacity, Draw-Out, 100% rated, complete with door mounted standard black handle, micrologic interchangeable harmonic 5.0H trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNG2NHNDSX
MDN4083LEA0522NMNG2NHNDSX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNG2NHNDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 2A/2B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0822NMNG4YNRCWX
MDN4083LEA0822NMNG4YNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNG4YNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price