1. Home / 
  2. breaker

SORT BY
Limited Stock
NRLF46080U74AE1
NRLF46080U74AE1
Schneider Electric - Molded Case
NRLF46080U74AE1, Schneider Electric, Square D, PowerPact, type , 4P, 3PH, 800A, 600V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, complete with micrologic interchangeable harmonic 6.0H trip with Modbus communications, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, lugs not included, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNK4NHNDPX
MDN4083LEA0322NMNK4NHNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNK4NHNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SHB1G3C2J
SHB1G3C2J
General Electric - Insulated Case
SHB1G3C2J, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & modbus communication features and 500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SED364000LSIES9C4
SED364000LSIES9C4
Schneider Electric - Insulated Case
SED364000LSIES9C4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 4000A, 600V, 100kA@480V, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD364000LIGES1D8
SEHD364000LIGES1D8
Square D - Insulated Case
SEHD364000LIGES1D8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 4000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SPB100-3P-1600A-EO-BO-LSI
SPB100-3P-1600A-EO-BO-LSI
Cutler Hammer - Insulated Case
SPB100-3P-1600A-EO-BO-LSI, Cutler Hammer, Systems Pow-R, type , larger frame size/non-compact frame size, 3P, 3PH, 1600A, 600V, 100kA@480V, standard interrupting capacity, Bolt-On, electrically operated, available with Pow-R Trip, Pow-R Trip 7, Digitrip RMS 510, 610, 810, 910, Digitrip OPTIM 750 and 1050, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers; these breakers are obsolete, however we still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNK4ENCMCX
MDN4083LEA0522NMNK4ENCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNK4ENCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0122NMNJNNNHCCX
MDN4083LEA0122NMNJNNNHCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNJNNNHCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0222NMNC2ENYDPX
MDN4083LEA0222NMNC2ENYDPX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNC2ENYDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSD1G2J3E
SSD1G2J3E
General Electric - Insulated Case
SSD1G2J3E, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 250A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF361600LSES8B8
SEHF361600LSES8B8
Square D - Insulated Case
SEHF361600LSES8B8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1600A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNE4ENYCWX
MDN4083LEA0522NMNE4ENYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNE4ENYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0622NMNG2ENRNWX
MDN4083LEA0622NMNG2ENRNWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNG2ENRNWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 32Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0822NMNENENRMAX
MDN4083LEA0822NMNENENRMAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNENENRMAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PEBB2ATGR0150
PEBB2ATGR0150
General Electric - Molded Case
PEBB2ATGR0150, General Electric, GuardEon, type , 1PH, 2P in 3P construction, 600V, 150A, 18kA@480V, 100% rated, front connection/Feed-Thru, toggle mechanism, complete with GTM interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; meet UL, cUL, IEC, CE, CCC requirements
From Get Price
Limited Stock
MDN4083LEA0722NMNJ4EHNCAX
MDN4083LEA0722NMNJ4EHNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNJ4EHNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHF2G5J7P
SHF2G5J7P
General Electric - Insulated Case
SHF2G5J7P, General Electric, Power Break II, type , 3P, 3PH, 600V, 1600A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, modbus communication & relays features and 1000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHF36400LSIGES1
SEHF36400LSIGES1
Schneider Electric - Insulated Case
SEHF36400LSIGES1, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNR4ENYDAX
MDN4083LEA0622NMNR4ENYDAX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR4ENYDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHF4G734U
SHF4G734U
General Electric - Insulated Case
SHF4G734U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2500A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, front connected, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communication & ZSI features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0222NMNE2YNCDAX
MDN4083LEA0222NMNE2YNCDAX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNE2YNCDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
PLP34080CU31BBD
PLP34080CU31BBD
Schneider Electric - Molded Case
PLP34080CU31BBD, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 800A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B overcurrent trip switch, micrologic interchangeable standard 3.0 trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHD36350LSES7A4
SEHD36350LSES7A4
Schneider Electric - Insulated Case
SEHD36350LSES7A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0522NMNANYNNMCX
MDN4083LEA0522NMNANYNNMCX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNANYNNMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price