1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
SEHD362500LIES1D4
SEHD362500LIES1D4
Square D - Insulated Case
SEHD362500LIES1D4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNHNNNYNAX
MDN4083LEA0122NMNHNNNYNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNHNNNYNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122AKHH4ENNNAX
MDN4083LEA0122AKHH4ENNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0122AKHH4ENNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, factory installed 110-127Vac shunt trip (ST), 48Vdc UVR & 4A/4B auxiliary switch, electrically operated with factory installed 48Vdc motor operator & spring release device (SRD), Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNA2YNCDSX
MDN4083LEA0322NMNA2YNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNA2YNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
SEHF36400ES3F8
SEHF36400ES3F8
Square D - Insulated Case
SEHF36400ES3F8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 48VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHB6G9K31
SHB6G9K31
General Electric - Insulated Case
SHB6G9K31, General Electric, Power Break II, type , 3P, 3PH, 600V, 4000A current sensor rating, 150kA@480V, high interrupting capacity, Bolt-On, back connected, 3000A frame rating, complete with Entelliguard trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 2500A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MDN4083LEA0822NMNH2ENRNCX
MDN4083LEA0822NMNH2ENRNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH2ENRNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNC2YNHCPX
MDN4083LEA0522NMNC2YNHCPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNC2YNHCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PLP34120U64AE1YP
PLP34120U64AE1YP
Schneider Electric - Molded Case
PLP34120U64AE1YP, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 1200A, 480V, 100kA@480V, UL listed, very high interrupting capacity, Bolt-On, complete with fixed handle padlocking device, micrologic interchangeable power 6.0P trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MGL26600UL
MGL26600UL
Square D - Molded Case
MGL26600UL, Square D, Schneider Electric, PowerPact, type , 2P, 1PH, 600A, 600V, 35kA@480V, UL listed, high interrupting capacity, Feed-Thru, complete with 48Vac UVR, basic non-interchangeable 1.0 trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0422NMNA2NNCMCX
MDN4083LEA0422NMNA2NNCMCX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNA2NNCMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
LGB2K070
LGB2K070
Siemens - Molded Case
LGB2K070, Siemens, GB2 Series, type , 2P, 1PH, 70A, 600Y/347V, 65kA@480V, panelboard mounting, Bolt-On, complete with LI - Long Time and Instantaneous trip functions, lugs not included, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNX4YNNDPX
MDN4083LEA0122NMNX4YNNDPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNX4YNNDPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
PDG32M0600P2DJ
PDG32M0600P2DJ
Cutler Hammer - Molded Case
PDG32M0600P2DJ, Eaton, Cutler Hammer, Power Defense, type , 1PH, 2P, 600V, 600A, 65kA@480V, Feed-Thru, line & load side lug terminals, complete with PXR25 trip with LSI - Long-Time, Short-Time and Instantaneous trip functions with MODBUS RTU, CAM link & relays, Solid State electronic, molded case circuit breakers; CSA, IEC, UL, CCC certifications
From Get Price
Limited Stock
SEHF363000LSIES2A8
SEHF363000LSIES2A8
Square D - Insulated Case
SEHF363000LSIES2A8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNC4YNNNAX
MDN4083LEA0822NMNC4YNNNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNC4YNNNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, mechanical trip indicator, & OTS switch, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
SHF1G2F2B
SHF1G2F2B
General Electric - Insulated Case
SHF1G2F2B, General Electric, Power Break II, type , 3P, 3PH, 600V, 400A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, full metering & modbus communication features and 150A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SHF2G4L1H
SHF2G4L1H
General Electric - Insulated Case
SHF2G4L1H, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 1600A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT & ZSI features and 400A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHD36600LSES4C8
SEHD36600LSES4C8
Square D - Insulated Case
SEHD36600LSES4C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SHF1G1F4C
SHF1G1F4C
General Electric - Insulated Case
SHF1G1F4C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, front connected, 800A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, full metering & modbus communication features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
MA363501212
MA363501212
Square D - Molded Case
MA363501212, Square D, I-Line, type , 3P, ABC phase connection, 3PH, 350A, 600V, 30kA@480V, standard interrupting capacity, I-Line Style Plug-In, complete with 1A/1B auxiliary switch, non-interchangeable trip LI - Long-Time and Instantaneous trip functions, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
SEHF362500LIGES5A4
SEHF362500LIGES5A4
Square D - Insulated Case
SEHF362500LIGES5A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 2500A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LIG - Long-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0422NMNC2ENKDWX
MDN4083LEA0422NMNC2ENKDWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNC2ENKDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
SSD4G4M1K
SSD4G4M1K
General Electric - Insulated Case
SSD4G4M1K, General Electric, Power Break II, type , 3P, 3PH, 600V, 1000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LI - Long-Time and Instantaneous trip functions, current metering, RELT, modbus communication & ZSI features and 600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price