1. Home / 
  2. 15 amp breaker

SORT BY
Limited Stock
WLS1D320LE
WLS1D320LE
Siemens - Insulated Case
WLS1D320LE, Siemens, WL Series, type , frame size I, drawout, 3P, 3PH, 2000A, 600V, 65kA@480V, UL listed, standard interrupting capacity, Draw-Out, complete with solid state ETU745 programmer + WLGFA48, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and 630A rating plug, Solid State electronic, low voltage insulated case circuit breakers
From Get Price
Limited Stock
SEHD36400LSIES5D5
SEHD36400LSIES5D5
Square D - Insulated Case
SEHD36400LSIES5D5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 24VDC shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHD363000LSES6E8
SEHD363000LSES6E8
Square D - Insulated Case
SEHD363000LSES6E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LS - Long-Time and Short-Time trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEF36200ES6E5
SEF36200ES6E5
Square D - Insulated Case
SEF36200ES6E5, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 48VDC shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
K600S-EO-BO-LI
K600S-EO-BO-LI
ABB - Air
K600S-EO-BO-LI, ABB, K-Line, type , 600A frame size, electrically operated/Bolt-On, 3P, 3PH, 600A, 600V, 30kA@480V, originally supplied with SS solid state trip device but can also be retrofitted with a modern Solid State electronic trip unit with LI - Long-Time and Instantaneous trip functions, low voltage power air circuit breakers
From Get Price
Limited Stock
MDN4083LEA0122NMNN2YNHDAX
MDN4083LEA0122NMNN2YNHDAX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNN2YNHDAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNA4ENYCPX
MDN4083LEA0522NMNA4ENYCPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNA4ENYCPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-127Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
MDN4083LEA0522NMNN2ENRNPX
MDN4083LEA0522NMNN2ENRNPX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNN2ENRNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 500A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SSD4G6F6U
SSD4G6F6U
General Electric - Insulated Case
SSD4G6F6U, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSH - Long-Time, Short-Time and High-Range Instantaneous trip functions, full metering & modbus communication features and 1600A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEHD361800LSIES9D4
SEHD361800LSIES9D4
Schneider Electric - Insulated Case
SEHD361800LSIES9D4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNHNNNYDSX
MDN4083LEA0122NMNHNNNYDSX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNHNNNYDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
Limited Stock
MDN4083LEA0522NMNX4NNRCAX
MDN4083LEA0522NMNX4NNRCAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNX4NNRCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 380-415Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0322NMNRNYNYDWX
MDN4083LEA0322NMNRNYNYDWX
Cutler Hammer - Insulated Case
MDN4083LEA0322NMNRNYNYDWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 300A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price
Limited Stock
LGC4500FAGH08
LGC4500FAGH08
Cutler Hammer - Molded Case
LGC4500FAGH08, Cutler Hammer, Series G, Type , 4P, 3PH, 500A, 600V, 100kA@480V, current limiting, UL listed for Marine applications, 40ºC, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0522NMNF4EHNCAX
MDN4083LEA0522NMNF4EHNCAX
Cutler Hammer - Insulated Case
MDN4083LEA0522NMNF4EHNCAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB plastic frame padlockable pushbutton cover, 3P, 3PH, 800A, 250A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0722NMNK4NNAMCX
MDN4083LEA0722NMNK4NNAMCX
Cutler Hammer - Insulated Case
MDN4083LEA0722NMNK4NNAMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 700A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SEHD364000LSGES8
SEHD364000LSGES8
Square D - Insulated Case
SEHD364000LSGES8, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 4000A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 24VDC shunt closing coil & 24VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0122NMNNNNNLCCX
MDN4083LEA0122NMNNNNNLCCX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNNNNNLCCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Castell key interlock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
SSD1G1B8C
SSD1G1B8C
General Electric - Insulated Case
SSD1G1B8C, General Electric, Power Break II, type , 3P, 3PH, 600V, 200A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering, RELT & modbus communication features and 200A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
SEF36350LIES9C8
SEF36350LIES9C8
Square D - Insulated Case
SEF36350LIES9C8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2 N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0822NMNJ2NNHMPX
MDN4083LEA0822NMNJ2NNHMPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNJ2NNHMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 480Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
SEF36350LSIGES4B4
SEF36350LSIGES4B4
Square D - Insulated Case
SEF36350LSIGES4B4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
LDS34250WU33X
LDS34250WU33X
Schneider Electric - Molded Case
LDS34250WU33X, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 250A, 480V, 18kA@480V, UL listed, standard interrupting capacity, rear connected, Bolt-On, suitable for reverse connection, complete with non-interchangeable mission critical standard 3.3S-W trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEHF361800LSIET7
SEHF361800LSIET7
Square D - Insulated Case
SEHF361800LSIET7, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & 125VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price